For potable water heating only.
Not suitable for space heating.
Not for use in mobile homes.
LOW LEAD
COMPLIANT
INSTALLER: Affi x these instructions to or near
the water heater.
OWNER: Retain these instructions for future
reference.
FOR YOUR SAFETY: An odorant is added to
the gas used by this water heater.
ADVERTENCIA
Si no puede leer o entender el inglés y necesita el manual de
instrucciones en español, puede solicitarlo al 1-800-821-2017. NO
TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA
SI NO ENTIENDE LAS INSTRUCCIONES. No hacer caso de esta
advertencia podría originar lesiones graves o mortales.
P/N 319588-002 (1010)
Sears Brands Management Corporation,
Hoffman Estates, IL 60179 U.S.A.
www.kenmore.com
www.sears.com
1
Page 2
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of
a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning
of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will result
in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result
in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, could result
in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, could result in property damage.
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and
how to avoid the risk of injury.
The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to
the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure
to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other
reproductive harm. This appliance can cause low-level exposure to some of the substances included in the act.
IMPORTANT DEFINITIONS
• Qualifi ed Technician: A qualifi ed technician must have ability equivalent to a licensed tradesman in the fi elds of plumbing, air supply,
venting, and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the
installation of gas fi red water heaters. The qualifi ed technician must also be familiar with the design features and use of fl ammable vapor
ignition resistant water heaters, and have a thorough understanding of this instruction manual.
• Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fi elds of plumbing, air supply, venting
and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of
gas fi red water heaters. The service agency must also have a thorough understanding of this instruction manual, and be able to perform
repairs strictly in accordance with the service guidelines provided by the manufacturer.
• Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this
application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural
gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.
SAFETY PRECAUTIONS
WARNING
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this
or any other appliance. Storage of or use of
FLAMMABLES
Flammable Vapors
gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance can result in
serious injury or death.
Read and follow water heater warnings and instructions.
SAFE INSTALLATION, USE AND SERVICE ...................................................................................................................... 2
Removing the Old Water Heater ...............................................................................................................................9
Facts to Consider About the Location ................................................................................................................ 10-11
Combustion Air and Ventilation Appliances in Unconfi ned Spaces ........................................................................12
Combustion Air and Ventilation Appliances in Confi ned Spaces .......................................................................12-13
Water Piping ......................................................................................................................................................13-14
T & P Valve and Pipe Insulation .............................................................................................................................14
Temperature Pressure Relief Valve ...................................................................................................................15,16
Filling the Water Heater ..........................................................................................................................................16
Gas Piping .........................................................................................................................................................17,18
Temperature Regulation .........................................................................................................................................20
Operating the Temperature Control System ...........................................................................................................21
SERVICE AND ADJUSTMENT ....................................................................................................................................... 22-27
Venting System Inspection .....................................................................................................................................22
Removing the Burner Door Assembly ....................................................................................................................23
Ultra Low NOx Natural Gas Burner ........................................................................................................................23
Replacing the Pilot/Thermopile Assembly ..............................................................................................................23
External Inspection & Cleaning of the Flame Trap .................................................................................................24
Cleaning the Combustion Chamber and Flame Trap .............................................................................................24
Replacing the Burner Door Assembly .....................................................................................................................25
Piezoelectric Igniter System ...................................................................................................................................25
Testing the Igniter System ......................................................................................................................................25
Removing and Replacing the Gas Control Valve/Thermostat ................................................................................26
Anode Rod Inspection .......................................................................................................................................26-27
Service ....................................................................................................................................................................27
Start Up Conditions ................................................................................................................................................28
Water Temperature Stacking .............................................................................................................................29
Air in Hot Water Faucets ...................................................................................................................................29
PARTS ORDER LIST ................................................................................................................................................................35
4
Page 5
PRODUCT WARRANTY
6 - YEAR LIMITED WARRANTY ON WATER HEATER
For six years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the
owner’s manual instructions and all local applicable plumbing codes, Sears will:
1. Supply free water heater parts for those that are defective in material or workmanship.
2. Supply a free water heater for one that develops a tank leak. See notes below also.
For the second through sixth year from the purchase date, you must pay the labor cost for installation of parts or water heater.
For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years. During
the second year you must pay the labor cost for parts or water heater installation.
If governmental regulations prohibit Sears from furnishing a comparable model replacement water heater under this warranty, Sears will
furnish a new water heater of comparable output as permitted by such governmental regulations; however, the Owner will be charged
for the additional cost associated with the changes made to comply with such governmental regulations.
Replacements furnished under this warranty do not carry a new warranty and are only covered by the unexpired portion of the original
warranty.
1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTY
For the fi rst year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones or a
new water heater for one that develops a leak.
WARRANTY SERVICE
To obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663).
This warranty applies only while this product is in use in the United States.
This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.
SEARS BRANDS MANAGEMENT CORPORATION, Hoffman Estates, IL 60179
The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears
warrants the installation.
A charge will be made on service calls due to poor or incomplete installation. These include:
a. Adjusting thermostat b. Condensation c. Leaks in pipes or fi ttings
Master Protection Agreements
Congratulations on making a smart purchase. Your new Kenmore
product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance
or repair from time to time. That’s when having a Master Protection
Agreement can save you money and aggravation.
The Master Protection Agreement also helps extend the life of your
new product. Here’s what the Agreement* includes:
Parts and labor• needed to help keep products operating
properly under normal use, not just defects. Our coverage
goes well beyond the product warranty. No deductibles, no
functional failure excluded from coverage— real protection.
Expert service• by a force of more than 10,000 authorized
Sears service technicians, which means someone you can
trust will be working on your product.
Unlimited service calls and nationwide service• , as often as
you want us, whenever you want us.
“No-lemon”• guarantee – replacement of your covered product
if four or more product failures occur within twelve months.
®
$250 Food Loss Protection• annually for any food spoilage that
is the result of mechanical failure of any covered refrigerator
or freezer.
Rental reimbursement• if repair of your covered product takes
longer than promised.
10% discount• off the regular price of any non-covered repair
service and related installed parts.
Once you purchase the Agreement, a simple phone call is all that it
takes for you to schedule service. You can call anytime day or night,
or schedule a service appointment online.
The Master Protection Agreement is a risk free purchase. If you cancel
for any reason during the product warranty period, we will provide a
full refund. Or, a prorated refund anytime after the product warranty
period expires. Purchase your Master Protection Agreement today!
Some limitations and exclusions apply. For prices and additional
information in the U.S.A. call 1-800-827-6655.
* Coverage in Canada varies on some items. For full details, call
Sears Canada at 1-800-361-6665.
Product replacement• if your covered product can’t be fixed.
Annual Preventive Maintenance Check• at your request – no
extra charge.
Fast help by phone• – we call it Rapid Resolution – phone
support from a Sears representative on all products. Think of
Sears Installation Service
For Sears professional installation of home appliances, garage door
openers, water heaters, and other major home items, in the U.S.A.
or Canada call 1-800-4-MY-HOME
®
.
us as a “talking owner’s manual.”
Power surge protection• against electrical damage due to
power fluctuations.
5
Page 6
CUSTOMER RESPONSIBILITIES
Thank You for purchasing a Kenmore water heater. Properly
installed and maintained, it should give you years of trouble free
service. If you should decide that you want the new water heater
professionally installed by Sears, call 1-800-4-MY-HOME
®
. They
will arrange for prompt, quality installation by Sears authorized
contractors.
Abbreviations Found In This Instruction Manual:
• CSA - Canadian Standards Association
• ANSI - American National Standards Institute
• NFPA - National Fire Protection Association
• ASME - American Society of Mechanical Engineers
• GAMA - Gas Appliance Manufacturers Association
• This gas-fired water heater is design certified by CSA
INTERNATIONAL under American National Standard/CSA
Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1
(current edition).
• Read the “Safety Precautions” section fi rst (pages 2 and 3 of
this manual) and then read the entire manual carefully. If you
don’t follow the safety rules, the water heater will not operate
properly. It could cause DEATH, SERIOUS BODILY INJURY
AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation,
and maintenance of the gas-fi red water heater. It also contains
warnings through out the manual that you must read and be
aware of. All warnings and all instructions are essential to the
proper operation of the water heater and your safety. Since
we cannot put everything on the fi rst few pages, READ THE
ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR
OPERATE THE WATER HEATER.
• The installation must conform with these instructions and
the local code authority having jurisdiction. In the absence
of local codes, installations shall comply with the current
edition of The National Fuel Gas Code ANSI Z223.1/NFPA
54. This publication is available from the Canadian Standards
Association, 8501 East Pleasant Valley Rd, Cleveland
Ohio 44131, or The National Fire Protection Association, 1
Batterymarch Park, Quincy, MA 02269.
• If after reading this manual you have any questions or do
not understand any portion of the instructions, call the Sears
Service Center.
• Carefully plan the place where you are going to put the
water heater. Correct combustion, vent action, and vent
pipe installation are very important in preventing death
from possible carbon monoxide poisoning and fi res. See fi gure 1.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
• For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.
Instructions may be obtained from the California Offi ce of the
State Architect, 1102 Q Street, Suite 5100, Sacramento, CA
95811. Instructions can also be downloaded to your computer
at WWW.dsa.dgs.ca.gov/Pubs.
• Complies with 10 ng/J SCAQMD rule #1121 and districts
having equivalent NOx requirements.
MODEL NUMBER
153.330200
153.330220
153.330230
TANK
CAPACITY IN
GALS (LTRS)
30 (114)
40 (151)
50 (189)
PRODUCT SPECIFICATIONS
RECOVERY
TYPE OF
GAS
NATURAL
NATURAL
NATURAL
INPUT
RATE
(Btu/hr)
30,000
40,000
40,000
RATE GALS.
PER HOUR @
90°F RISE
31
41
41
3” (76) OR 4” (102)
3” (76) OR 4” (102)
3” (76) OR 4” (102)
MINIMUM
VENT PIPE
INCHES
(mm)
DIAMETER
INCHES
(mm)
16 (406)
18 (457)
20 (508)
DIMENSIONS IN
INCHES (mm)
HEIGHT TO
JACKET TOP
56-3/8 (1432)
58-5/8 (1489)
57-3/8 (1457)
6
Page 7
MATERIALS AND BASIC TOOLS NEEDED
MATERIALS NEEDED
To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials,
depending on your type of installation.
EXPANSION TANKS FOR
THERMAL EXPANSION
CONDITIONS AVAILABLE
IN 2 GALLONS
(7.6 LITERS) AND
5 GALLONS (18.9 LITERS)
CAPACITY THROUGH
LOCAL SEARS STORE
OR SERVICE CENTER.
WATER HEATER INSTALLATION KIT
WITH FLEXIBLE CONNECTORS FOR 3/4”
(19.05 mm) COPPER PLUMBING AND FLEXIBLE
GAS CONNECTOR WITH FITTINGS.
BASIC TOOLS
You may or may not need all these tools, depending on your
type of installation. These tools can be purchased at your local
Sears Store.
• Pipe Wrenches (2) 14” (356 mm)
• Screwdriver
• Tin Snips
• 6’ (1.82 m) Tape or Folding Ruler
• Garden Hose
• Drill
• Pipe Dope or Tefl on Tape
SLOT-HEAD SCREWDRIVER
DRILL
METAL DRAIN PANS
AVAILABLE IN 20” (508
mm) DIAMETER FOR
WATER HEATERS HAVING A
DIAMETER 18” (457 mm) OR
LESS, 24” (610mm) DIAMETER
FOR WATER HEATERS HAVING
A DIAMETER 22” (559 mm)
OR LESS AND AVAILABLE IN
28” (711 mm) DIAMETER FOR
WATER HEATERS HAVING A
DIAMETER 26” (660 mm) OR
LESS.
ADDITIONAL TOOLS NEEDED
WHEN SWEAT SOLDERING
• Tubing Cutters or Hacksaw
• Propane Torch
• Soft Solder
• Solder Flux
• Emery Cloth
• Wire Brushes
TUBING CUTTER
PROPANE
TORCH
PHILLIPS SCREWDRIVER
ROLL OF TEFLON
TAPE (USE ONLY ON
WATER CONNECTIONS)
GARDEN HOSE
6 FOOT TAPE
TIN SNIPS
PIPE DOPE
(SQUEEZE TUBE)
USE FOR WATER AND GAS
CONNECTIONS
PIPE WRENCH
3/4” (19 mm) WIRE BRUSH
1/2” (13 mm) WIRE BRUSH
7
HACKSAW
EMERY CLOTH
ROLL OF LEAD-FREE
SOFT SOLDER
ROLL OF
SOLDER
FLUX
Page 8
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Draft Hood
C Anode
D Hot Water Outlet
E Outlet
F Flexible Water Connections
G Gas Supply
H Manual Gas Shut-off Valve
I Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT
TERMINATION ON
ROOF
A
INSTALL THERMAL EXPANSION
TANK IF WATER HEATER IS
INSTALLED IN A CLOSED
M
F
J Drip Leg (Sediment Trap)
K Inner Door
L Outer Door
M Union
N Inlet Water Shut-off Valve
O Cold Water Inlet
P Inlet Dip Tube
Q Temperature-Pressure Relief Valve
R Rating Plate
WATER SYSTEM
N
O
S Flue Baffl e
T Gas Control Valve/Thermostat
U Drain Valve
V Pilot and Burner Door Assemblies
W Flue
X Metal Drain Pan
(T) GAS CONTROL VALVE/
THERMOSTAT
VAC
B
F
D
E
S
C
G
H
I
J
X
W
V
K
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
P
R
T
U
L
VACUUM RELIEF
VALV E
*INSTALL PER
LOCAL CODES
Q
DISCHARGE PIPE
(Do not cap or plug)
6” MAXIMUM
AIR GAP
FIGURE 1.
(V) PILOT AND BUNER DOOR
ASSEMBLIES
SENSOR WIRES
IGNITER
WIRE
MANIFOLD TUBE
PILOT TUBE
MAIN BURNER
PILOT
ASSEMBLY
(SEE BELOW)
BURNER DOOR
PILOT
ASSEMBLY
FRONT VIEW
TOP VIEW
THERMOPILE
CONNECTORS
RETAINER
CLIP
MANIFOLD
COMPONENT
BLOCK
8
Page 9
INSTALLATION INSTRUCTIONS
Removing the Old Water Heater
1
MANUAL GAS
SHUT-OFF VALVE
GROUND
JOINT
UNION
CHECK WITH
LOCAL UTILITY
FOR MINIMUM HEIGHT
3” MINIMUM
DRIP LEG
6
5
3
SUITABLE
DRAIN
FIGURE 2.
2
DISCHARGE PIPE
4
(DO NOT CAP
OR PLUG)
6” MAXIMUM
AIR GAP
4. Attach a hose to the water heater
drain valve and put the other end
in a fl oor drain or outdoors. (See
Figures 2 and 5.) Open the water
heater drain valve.
5. Disconnect the vent pipe from
the draft hood where it connects
to the water heater. In most
installations the vent pipe can be
lifted off after any screw or other
FIGURE 5.
attached devices are removed. Dispose of the draft hood.
The new water heater has a draft hood which must be used
for proper operation.
6. If you have copper piping to the water heater, the two copper
water pipes can be cut with a hacksaw approximately four
inches away from where they connect to the water heater.
See Figure 6. This will avoid cutting off pipes too short.
Additional cuts can be made later if necessary. Disconnect the
temperature-pressure relief valve drain line. When the water
heater is drained, disconnect the hose from the drain valve.
Close the drain valve. The water heater is now completely
disconnected and ready to be removed.
1. Turn “OFF” the gas supply to
the water heater.
If the main gas line shutoff valve
serving all gas appliances is used,
also shut “OFF” the gas at each
appliance. Leave all gas appliances
shut “OFF” until the water heater
installation is completed. See
Figures 2 and 3.
FIGURE 3.
2. Open a nearby hot water faucet
until the water is no longer hot.
When the water has cooled, turn
“OFF” the water supply to the water
heater at the water shut off valve
or water meter. Some installations
require that the water be turned off
to the entire house. See Figures 2
FIGURE 4.
and 4.
3. Check again to make sure the gas supply is “OFF” to the water
heater. Then disconnect the gas supply connection from the
gas control valve.
FIGURE 6.
If you have galvanized pipes to the water heater, loosen
the two galvanized pipes with a pipe wrench at the union in
each line. Also disconnect the piping remaining to the water
heater. See Figure 7. These pieces should be saved since
they may be needed when reconnecting the new water heater.
Disconnect the temperature-pressure relief valve drain line.
When the water heater is drained, disconnect the hose from
the drain valve. Close the drain valve. The water heater
is now completely disconnected and ready to be removed.
Mineral buildup or sediment may have accumulated in the
old water heater. This causes the water heater to be much
heavier than normal and this residue, if spilled out, could
cause staining.
FIGURE 7.
9
Page 10
Facts to Consider About
the Location
Carefully choose an indoor location for the new water heater.
The placement is a very important consideration for the safety
of the occupants in the building and for the most economical
use of the appliance. This water heater is not for use in
manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed:
• Select a location indoors as close as practical to the gas
vent or chimney to which the water heater vent is going to be
connected, and as centralized with the water piping system
as possible.
• Selected location must provide adequate clearances for
servicing and proper operation of the water heater.
Installation of the water heater must be accomplished in such a
manner that if the tank or any connections should leak, the fl ow
will not cause damage to the structure. For this reason, it is not
advisable to install the water heater in an attic or upper fl oor. When
such locations cannot be avoided, a suitable metal drain pan should
be installed under the water heater. Metal drain pans are available
at your local Sears or hardware store. Such a drain pan must have
a minimum length and width of at least 2 inches (51 mm) greater
than the water heater dimensions and must be piped to an adequate
drain. The pan must not restrict combustion air fl ow.
• Devices that will turn off the gas supply to a gas water heater
while at the same time shutting off its water supply.
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS
(VAPORS) ARE LIKELY TO BE PRESENT OR STORED
(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable
liquids (such as gasoline, solvents, propane [LP or butane, etc.]
and other substances such as adhesives, etc.) emit fl ammable
vapors which can be ignited by a gas water heater’s pilot light or
main burner. The resulting fl ashback and fi re can cause death
or serious burns to anyone in the area. Even though this water
heater is a fl ammable vapor ignition resistant water heater and
is designed to reduce the chances of fl ammable vapors being
ignited, gasoline and other fl ammable substances should never
be stored or used in the same vicinity or area containing a gas
water heater or other open fl ame or spark producing appliance.
Also, the water heater must be located and/or protected so it is
not subject to physical damage by a moving vehicle.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a metal drain
pan piped to a drain. Unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used
in conjunction with a piped metal drain pan. These devices are
available from some plumbing supply wholesalers and retailers,
and detect and react to leakage in various ways:
• Sensors mounted in the metal drain pan that trigger an alarm
or turn off the incoming water to the water heater when leakage
is detected.
• Sensors mounted in the metal drain pan that turn off the water
supply to the entire home when water is detected in the metal
drain pan.
• Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water
pipes connected to the water heater.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath
the appliance extending beyond the full width and depth of the
appliance by at least 3 inches (76.2mm) in any direction, or if
the appliance is installed in an alcove or closet, the entire fl oor
must be covered by the panel. Failure to heed this warning may
result in a fi re hazard.
10
Page 11
Minimum clearances between the water heater and combustible
surfaces are 0 inch at the sides and rear, 4 inches (102 mm)
at the front, and 6 inches (153 mm) from the vent pipe. See
Figure 8. Clearance from the top of the jacket is 8 inches (203
mm) on most models. Note that a lesser dimension may be
allowed on some models. Refer to the label attached adjacent
to the gas control valve on the water heater.
FIGURE 8.
FIGURE 9.
If this water heater will be used in beauty shops, barber shops,
cleaning establishments, or self-service laundries with dry
cleaning equipment, it is imperative that the water heater or
water heaters be installed so that combustion and ventilation
air be taken directly from outdoors (direct vent).
Propellants of aerosol sprays and volatile compounds, (cleaners,
chlorine based chemicals, refrigerants, etc.) in addition to being
highly fl ammable in many cases, will also change to corrosive
hydrochloric acid when exposed to the combustion products of
the water heater. The results can be hazardous, and also cause
product failure.
Insulation Blankets
Insulation blankets available to the general public for external
use on gas water heaters are not necessary with Kenmore
products. The purpose of an insulation blanket is to reduce the
standby heat loss encountered with storage tank heaters. Your
Kenmore water heater meets or exceeds the National Appliance
Energy Conservation Act standards with respect to insulation
and standby loss requirements, making an insulation blanket
unnecessary.
A gas water heater cannot operate properly without the correct
amount of air for combustion. See Figure 9. Do not install in a
confi ned area such as a closet, unless you provide air as shown
in the Locating The New Water Heater section. Never obstruct
the fl ow of ventilation air. If you have any doubts or questions at
all, call your gas supplier. Failure to provide the proper amount of
combustion air can result in a fi re or explosion and cause death,
serious bodily injury, or property damage.
WARNING
Should you choose to apply an insulation blanket to this
heater, you should follow these instructions (See Figure 1 for
identifi cation of components mentioned below). Failure to follow
these instructions can restrict the air fl ow required for proper
combustion, potentially resulting in fi re, asphyxiation, serious
personal injury or death.
• Do not apply insulation to the top of the water heater, as this
will interfere with safe operation of the draft hood.
• Do not cover the outer door, thermostat or temperature &
pressure relief valve.
• Do not allow insulation to come within 2” (50.8 mm) of the fl oor
to prevent blockage of combustion air fl ow to the burner.
• Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
11
Page 12
• Do obtain new warning and instruction labels from Sears for
placement on the blanket directly over the existing labels.
• Do inspect the insulation blanket frequently to make certain
it does not sag, thereby obstructing combustion air fl ow.
Combustion Air and Ventilation for
Appliances Located in Unconfi ned Spaces
The confi ned space shall be provided with two permanent
openings, one commencing within 12 inches (30 cm) of the top
and one commencing within 12 inches (30 cm) from the bottom
of the enclosure. The openings shall communicate directly, or
by ducts, with the outdoors or spaces (crawl or attic) that freely
communicate with the outdoors.
UNCONFINED SPACE is space whose volume is not less than
50 cubic feet per 1,000 Btu per hour (4.8 m
aggregate input rating of all appliances installed in that space.
Rooms communicating directly with the space in which the
appliances are installed, through openings not furnished with
doors, are considered a part of the unconfi ned space.
In unconfi ned spaces in buildings, infi ltration may be adequate
to provide air for combustion, ventilation and dilution of fl ue
gases. However, in buildings of tight construction (for example,
weather stripping, heavily insulated, caulked, vapor barrier,
etc.), additional air may need to be provided using the methods
described in Combustion Air and Ventilation for Appliances Located in Confi ned Spaces.
3
per kW) of the
Combustion Air and Ventilation for
Appliances Located in Confi ned Spaces
CONFINED SPACE is a space whose volume is less than
50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the
aggregate input rating of all appliances installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figure 9 on page 11 and Figure 10 below)
The confi ned space shall be provided with two permanent
openings communicating directly with an additional room(s) of
suffi cient volume so that the combined volume of all spaces
meets the criteria for an unconfi ned space. The total input of all
gas utilization equipment installed in the combined space shall
be considered in making this determination. Each opening shall
have a minimum free area of one square inch per 1,000 Btu per
hour (22 cm2/kW) of the total input rating of all gas utilization
equipment in the confi ned space, but not less than 100 square
inches (645 cm2). One opening shall commence within 12 inches
(30 cm) of the top and one commencing within 12 inches (30
cm) of the bottom of the enclosures.
FIGURE 11.
• When directly communicating with the outdoors, each opening
shall have a minimum free area of 1 square inch per 4,000
Btu per hour (5.5 cm2/kW) of total input rating of all equipment
in the enclosure. See Figure 11.
• When communicating with the outdoors through vertical
ducts, each opening shall have a minimum free area of
1 square inch per 4,000 BTU per hour (5.5 cm2/kW) of
total input rating of all equipment in the enclosure. See
Figure 12.
FIGURE 10.
B. ALL AIR FROM OUTDOORS: (See Figures 9, 11,12,13 and 13A)
FIGURE 12.
• When communicating with the outdoors through horizontal
ducts, each opening shall have a minimum free area of
1 square inch per 2,000 BTU per hour (11 cm
total input rating of all equipment in the enclosure. See
Figure 13.
• When ducts are used, they shall be of the same crosssectional area as the free area of the openings to which
they connect. The minimum short side dimension of
rectangular air ducts shall not be less than 3 inches
(7.6 cm). See Figure 13.
12
2
/kW) of
Page 13
FIGURE 13.
Water Piping
• Alternatively, a single permanent opening may be used when
communicating directly with the outdoors, or with spaces that
freely communicate with the outdoors. The opening shall
have a minimum free area of 1 square inch per 3,000 BTU
per hour (7.3 cm²/kW) of total input rating of all equipment in
the enclosure. See Figure 13A.
FIGURE 13A.
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water
heated to a temperature which will satisfy space heating,
clothes washing, dish washing, cleaning and other sanitizing
needs can scald and permanently injure you upon contact.
Some people are more likely to be permanently injured by
hot water than others. These include the elderly, children, the
infi rm, or physically/mentally handicapped. If anyone using hot
water in your home fi ts into one of these groups or if there is a
local code or state law requiring a certain temperature water
at the hot water tap, then you must take special precautions.
In addition to using the lowest possible temperature setting
that satisfi es your hot water needs, a means such as a *mixing
valve should be used at the hot water taps used by these
people or at the water heater. Mixing valves are available at
plumbing supply or hardware stores. See Figure 14. Valves
for reducing point of use temperature by mixing cold and hot
water are also available. Follow manufacturer’s instructions
for installation of the valves. Before changing the factory
setting on the thermostat, read the Temperature Regulation
section in this manual.
• Louvers and Grilles: In calculating free area, consideration
shall be given to the blocking effect of louvers, grilles or
screens protecting openings. Screens used shall not be
smaller than 1/4 inch (6.4 mm) mesh. If the free area through
a design of louver or grille is known, it should be used in
calculating the size opening required to provide the free area
specifi ed. If the design and free area is not known, it may be
assumed that wood louvers will be 20-25 percent free area
and metal louvers and grilles will have 60-75 percent free
area. Louvers and grilles shall be fi xed in the open position
or interlocked with the equipment so that they are opened
automatically during equipment operation.
• Special Conditions Created by Mechanical Exhausting or
Fireplaces: operation of exhaust fans, ventilation systems,
clothes dryers or fi replaces may create conditions requiring
special attention to avoid unsatisfactory operation of installed
gas utilization equipment.
FIGURE 14.
13
Page 14
This water heater shall not be connected to any heating
systems or component(s) used with a non-potable water heating
appliance.
Toxic chemicals, such as those used for boiler treatment, shall
not be introduced into this system.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed on
the supply to the entire house in order to maintain equal hot and
cold water pressures.
In addition, the water within the water heater tank expands as
it is heated, increasing the pressure of the water system. If the
relieving point of the water heater’s temperature-pressure relief
valve is reached, the valve will relieve the excess pressure. The
temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable
condition and must be corrected. It is recommended that any
devices installed which could create a closed system have a
by-pass and/or the system have an expansion tank to relieve the
pressure built by thermal expansion in the water system. Refer
to the Thermal Expansion section under Troubleshooting Guide
or contact local plumbing authority or local Sears Service Center
on how to control this situation.
NOTE: To protect against untimely corrosion of hot and cold
water fi ttings, it is strongly recommended that di-electric
unions or couplings be installed on this water heater when
connected to copper pipe.
INSTALLATION COMPLETED USING
HOT WATER
OUTLET
THREADED TO
SWEAT COUPLING
3/4” THREADED
COUPLING
INSTALLATION KIT
FLEXIBLE
WATER
CONNECTORS
THREADED TO
SWEAT COUPLING
3/4” THREADED
COUPLING
DRAFT HOOD
SHUTOFF
VALV E
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE PIPE
(Do not cap or plug)
COLD WATER
INLET
Figure 15 shows the typical attachment of the water piping to
the water heater. The water heater is equipped with 3/4” NPT
water connections.
NOTE: If using copper tubing, solder tubing to an adapter
before attaching the adapter to the cold water inlet
connection. Do not solder the cold water supply line directly
to the cold water inlet. It will harm the dip tube and damage
the tank.
• Look at the top cover of the water heater. The water outlet is
marked “HOT”. Put two or three turns of Tefl on tape around the
threaded end of the threaded-to-sweat coupling and around
both ends of the 3/4” NPT threaded nipple. Using fl exible
connectors, connect the hot water pipe to the hot water outlet
on the water heater.
• Look at the top of the water heater. The cold water inlet is
marked “COLD”. Put two or three turns of Tefl on tape around
the threaded end of the threaded-to-sweat coupling and
around both ends of the 3/4” NPT threaded nipple. Using
fl exible connectors, connect the cold water pipe to the cold
water inlet of the water heater.
NOTE:This water heater is super insulated to minimize
heat loss from the tank. Further reduction in heat loss
can be accomplished by insulating the hot water lines
from the water heater.
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.
6” MAXIMUM
AIR GAP
FLOOR DRAIN
FIGURE 15.
T & P Valve and Pipe Insulation
1. Locate the temperature and pressure relief valve on the
water heater (also known as a T&P relief valve). See
Figure 15A.
2. Locate the slit running the length of the T&P relief valve
insulation.
3. Spread the slit open and fi t the insulation over the T&P
relief valve. See Figure 15A. Apply gentle pressure to the
insulation to ensure that it is fully seated on the T&P Relief
Valve. Once seated, secure the insulation with duct tape.
IMPORTANT: The insulation or tape should not block or
cover the T&P relief valve drain opening. Also, the insulation
or tape should not block or hinder access to the manual
relief lever (Figure 15A).
4. Locate the hot water (outlet) & cold water (inlet) pipes to the
water heater.
Locate the slit running the length of a section of pipe insulation.
5.
6. Spread the slit open and slip the insulation over the cold
water (inlet) pipe. Apply gentle pressure along the length of
the insulation to ensure that it is fully seated around the pipe.
Also, ensure that the base of the insulation is fl ush with the water
heater. Once seated, secure the insulation with duct tape.
7. Repeat steps 5 and 6 for the hot water (outlet) pipe.
8. Add additional sections of pipe insulation as needed.
14
Page 15
T&P RELIEF VALVE
T&P RELIEF VALVE
DRAIN LINE
MANUAL RELIEF LEVER
T&P RELIEF VALVE INSULATION
FIGURE 15A.
Temperature-Pressure Relief Valve
HOT WATER
OUTLET
HOT
DRAFT HOOD
COLD WATER
INLET
SHUTOFF
VALV E
COLD
TEMPERATURE - PRESSURE
RELIEF VALVE
(OPTIONAL TOP T&P RELIEF
VALVE NOT SHOWN)
DISCHARGE PIPE
(Do not cap or plug)
DRAIN VALVE
6” MAXIMUM
AIR GAP
This heater is provided with a properly certifi ed combination
temperature - pressure relief valve by the manufacturer.
The valve is certifi ed by a nationally recognized testing laboratory
that maintains periodic inspection of production of listed
equipment as meeting the requirements for Relief Valves for Hot
Water Supply Systems, ANSI Z21.22 and the code requirements
of ASME.
If replaced, the valve must meet the requirements of local codes,
but not less than a combination temperature and pressure relief
valve certifi ed as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to
exceed the marked hydrostatic working pressure of the water
heater (150 psi = 1,035kPa) and a discharge capacity not less than
the water heater input rate as shown on the model rating plate.
For safe operation of the water heater, the relief valve must not
be removed from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly
into the fi tting of the water heater designed for the relief valve.
Position the valve downward and provide tubing so that any
discharge will exit only within 6 inches (15.3 cm) above, or
at any distance below the structural fl oor, see Figure 16. Be
certain that no contact is made with any live electrical part.
The discharge opening must not be blocked or reduced in
size under any circumstances. Excessive length, over 30 feet
(9.14 m), or use of more than four elbows can cause restriction
and reduce the discharge capacity of the valve.
No valve or other obstruction is to be placed between the relief
valve and the tank. Do not connect tubing directly to discharge
drain unless a 6 inch air gap is provided. To prevent bodily
injury, hazard to life, or property damage, the relief valve must
be allowed to discharge water in quantities should circumstances
FIGURE 16.
FLOOR DRAIN
demand. If the discharge pipe is not connected to a drain or other
suitable means, the water fl ow may cause property damage.
The Discharge Pipe:
• Shall not be smaller in size than the outlet pipe size of the
valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both the
temperature-pressure relief valve, and the discharge pipe.
• Shall terminate a maximum of six inches above a fl oor drain
or external to the building. In cold climates, it is recommended
that the discharge pipe be terminated at an adequate drain
inside the building.
• Shall terminate at an adequate drain.
• Shall not have any valve between the relief valve and tank.
15
Page 16
The temperature-pressure relief valve must be manually operated
at least once a year. Caution should be taken to ensure that
(1) no one is in front of or around the outlet of the temperaturepressure relief valve discharge line, and (2) the water manually
discharged will not cause any bodily injury or property damage
because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold water
inlet to the water heater, follow the draining instructions, and
replace the temperature-pressure relief valve with a new one.
Filling the Water Heater
Never use this water heater unless it is completely full of water.
To prevent damage to the tank, the tank must be fi lled with water.
Water must fl ow from the hot water faucet before turning “ON”
gas to the water heater.
To fi ll the water heater with water:
• Close the water heater drain valve by inserting a fl at head
screwdriver in the slot on the stem and turn to the right
(clockwise). The drain valve is on the lower front of the water
heater.
• Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.
• To ensure complete fi lling of the tank, allow air to exit by
opening the nearest hot water faucet. Allow water to run until
a constant fl ow is obtained. This will let air out of the water
heater and the piping.
• Check all water piping and connections for leaks. Repair as
needed.
of any vent damper, consult your local Sears Service Center or
the local gas supplier for further information.
To ensure proper venting of this gas-fi red water heater, the
correct vent pipe diameter must be utilized. Any additions or
deletions of other gas appliances on a common vent with this
water heater may adversely affect the operation of the water
heater. Consult your gas supplier if any such changes are
planned. For replacement heater installations where preexisting venting is used, the venting must be inspected for
obstructions and if deterioration is present, it must be replaced.
IMPORTANT: Do not common vent this water heater with any
power vented appliance.
For proper venting in certain installations, a larger diameter vent
pipe may be necessary. Consult your local Sears Service Center
or gas supplier to aid you in determining the proper venting for
your water heater from the vent tables in the current edition of
the National Fuel Gas Code ANSI Z223.1/NFPA 54.
Periodically check the venting system for signs of obstruction or
deterioration and replace if needed.
The combustion and ventilation air flow must not be
obstructed.
Venting
VENT DAMPERS - Any vent damper, whether it is operated
thermally or otherwise must be removed if its use inhibits proper
drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fi red water heaters
having thermal effi ciency in excess of 80% may produce a
relatively low fl ue gas temperature. Such temperatures may
not be high enough to properly open thermally operated vent
dampers. This would cause spillage of the fl ue gases and may
cause carbon monoxide poisoning.
Vent dampers must bear evidence of certifi cation as complying
with the current edition of the American National Standard
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically
and mechanically actuated vent dampers). Before installation
The water heater with draft hood installed must be connected
to a chimney or listed vent pipe system, which terminates to the
outdoors. Never operate the water heater unless it is vented
to the outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.
• For proper draft hood attachment, the draft hood legs may
be angled slightly inward.
• Place the draft hood legs in the receiving holes on the top
of the water heater. The legs will snap in the holes to give a
tight fi t. Secure the legs to top with sheet metal screws. See
Figure 17.
• Place the vent pipe over the draft hood. With the vent pipe
in position, drill a small hole through both the vent pipe and
draft hood. Secure them together with a sheet metal screw.
Obstructed or deteriorated vent systems may present serious
health risk or asphyxiation.
16
Page 17
FIGURE 17.
The vent pipe from the water heater must be no less than the
diameter of the draft hood outlet on the water heater and must
slope upward at least 1/4 inch per linear foot (21 mm per meter).
See Figure 18.
Chemical vapor corrosion of the fl ue and vent system may occur
if air for combustion contains certain chemical vapors. Spray can
propellants, cleaning solvents, refrigerator and air conditioner
refrigerants, swimming pool chemicals, calcium and sodium
chloride, waxes, bleach and process chemicals are typical
compounds which are potentially corrosive.
Gas Piping
FIGURE 18.
All vent gases must be completely vented to the outdoors of the
structure (dwelling). Install only the draft hood provided with the
new water heater and no other draft hood.
Vent pipes must be secured at each joint with sheet metal
screws.
There must be a minimum of 6 inches (153 mm) clearance
between single wall vent pipe and any combustible surface.
Fill and seal any clearance between single wall vent pipe
and combustible surfaces with mortar mix, cement, or other
noncombustible substance. For other than single wall, follow
vent pipe manufacturer’s clearance specifi cations. To ensure a
tight fi t of the vent pipe in a brick chimney, seal around the vent
pipe with mortar mix cement.
Failure to have required clearances between vent piping and
combustible surfaces will result in a fi re hazard.
Be sure vent pipe is properly connected to prevent escape of
dangerous fl ue gases which could cause deadly asphyxiation.
Make sure the gas supplied is the same type listed on the
model rating plate. The inlet gas pressure must not exceed
14 inch water column (3.5kPa) for natural and propane gas (L.P.)
gas. The minimum inlet gas pressure listed on the rating plate
is for the purpose of input adjustment. If the gas control valve
is subjected to pressures exceeding 1/2 pound per square inch
(3.5kPa), the damage to the gas control valve could result in a
fi re or explosion from leaking gas.
If the main gas line shutoff serving all gas appliances is used, also
turn “OFF” the gas at each appliance. Leave all gas appliances
shut “OFF” until the water heater installation is complete.
A gas line of suffi cient size must be run to the water heater.
Consult the current edition of National Fuel Gas Code ANSI
Z223.1/NFPA 54 and your gas supplier concerning pipe size.
There must be:
• A readily accessible manual shut off valve in the gas supply
line serving the water heater.
• A drip leg (sediment trap) ahead of the gas control valve to
help prevent dirt and foreign materials from entering the gas
control valve.
• A fl exible gas connector or a ground joint union between the
shut off valve and control valve to permit servicing of the
unit.
Be sure to check all the gas piping for leaks before lighting the
water heater. Use a soapy water solution, not a match or open
fl ame. Rinse off soapy solution and wipe dry.
The minimum inlet gas pressure shown on the rating plate is that
which will permit fi ring at the rated input.
17
Page 18
Sediment Traps
Water heaters covered in this manual have been tested
and approved for installation at elevations up to 2,000 feet
(610 m) above sea level. For installation above 2,000 feet
(610 m), the water heater’s Btu input should be reduced at the
rate of 4 percent for each 1,000 feet (305 m) above sea level
which requires replacement of the burner orifi ce in accordance
with the National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact
your local gas supplier for further information.
Failure to replace the standard orifi ce with the proper high
altitude orifi ce when installed at elevations above 2,000 feet
(610 m) could result in improper and ineffi cient operation of the
appliance, producing carbon monoxide gas in excess of the safe
limits. This could result in serious injury or death. Contact your
local gas supplier for any specifi c changes that may be required
in your area.
Contaminants in the gas lines may cause improper operation
of the gas control valve that may result in fi re or explosion.
Before attaching the gas line be sure that all gas pipe is clean
on the inside. To trap any dirt or foreign material in the gas
supply line, a drip leg (sometimes called a sediment trap) must
be incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the Gas Piping section.
Refer to the current edition of the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
A sediment trap shall be installed as close to the inlet of the water
heater as practical at the time of water heater installation. The
sediment trap shall be either a tee fi tting with a capped nipple
in the bottom outlet or other device recognized as an effective
sediment trap. If a tee fi tting is used, it shall be installed in
conformance with one of the methods of installation, shown in
Figures 19 and 20.
GROUND JOINT
UNION
(OPTIONAL)
GAS CONTROL
VALVE / THERMOSTAT
Use pipe joint compound or Tefl on tape marked as being resistant
to the action of petroleum (Propane [L.P.]) gases.
The appliance and its gas connection must be leak tested before
placing the appliance in operation.
The appliance and its individual shutoff valve shall be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 pound per square inch (3.5 kPa). It shall be isolated from
the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 pound per
square inch (3.5 kPa).
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown
in Figures 19 and 20.
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.
3” MIN.
(76.2 mm)
DRIP LEG
(SEDIMENT TRAP)
FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.
GROUND JOINT
UNION
(OPTIONAL)
3” MIN.
(76.2 mm)
BLACK PIPE
DRIP LEG
(SEDIMENT TRAP)
VALVE / THERMOSTAT
FIGURE 20. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.
18
GAS CONTROL
Page 19
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which is lighted by a
piezoelectric igniter. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire
department.
LIGHTING INSTRUCTIONS
1. STOP! It is imperative that you read all safety warnings
before lighting the pilot.
2. Turn the gas control/temperature knob counterclockwise
to the "OFF" setting.
Gas control/
temperature knob
Igniter
Button
Status light
3. Wait ten (10) minutes to clear out any gas.
If you then smell gas, STOP! Follow “B” in the safety
information above on this label. If you do not smell gas,
go to the next step.
4. Turn the gas control/temperature knob clockwise
to “ PILOT” .
120° F (48.9° C)
Mark
Index mark
C. Use only your hand to push in or turn the gas control
temperature knob. Never use tools. If the knob will not
push in or move by hand, don’t try to repair it, call a
qualified service technician. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance. Water heaters subjected to flood
conditions or anytime the gas controls, main burner or
pilot have been submerged in water require replacement
of the entire water heater.
E. DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN
IGNITION OF VAPORS. Immediately call a qualified service
technician to inspect the appliance. Water heaters
subjected to a flammable vapors ignition will show a
discoloration on the air intake grid (bottom of combustion
chamber) and require replacement of the entire water heater.
Press the gas control/temperature knob all the way in
5.
and hold it in. The knob should travel in about 1/4 inch
(6.35 mm) if it is set to "PILOT" correctly.
While holding the gas control/temperature knob in,
click the igniter button continuously (about once a
second) for up to 90 seconds or until Status Light
begins to blink.
When the status light starts blinking, release the gas
6.
control/temperature knob. Set the gas control/ temperature knob to the desired setting.
If the status light does not start blinking within 90
seconds, repeat steps 2 through 5 up to THREE (3)
times, waiting 10 minutes between lighting attempts.
The circuitry in this advanced gas valve requires that
you wait 10 minutes between lighting attempts.
If the status light turns solid red, release the gas
control/temperature knob and repeat steps 2 through 5
(waiting 10 minutes before attempting to relight the pilot).
If the status light does not start blinking after three lighting
attempts, turn the gas control/temperature knob to "OFF"
and call a qualified service technician or your gas supplier.
Thermopile
TO TURN OFF GAS TO APPLIANCE
1. Turn the gas control/temperature knob counterclockwise to
the "OFF" setting. The status light will stop blinking and stay on for a
short time after the water heater is turned off.
19
Pilot
Page 20
Temperature Regulation
The thermostat is adjusted to the pilot position when
it is shipped from the factory. Water temperature can
be regulated by moving the temperature dial to the
preferred setting. The preferred starting point is 120°F
at the “HOT” setting. Align the knob with the desired
water temperature as shown in Figure 22. There is a
hot water scald potential if the thermostat is set too high.
NOTE: Temperatures shown on the gas control valve/
thermostat are approximates. The actual temperature of
the heated water may vary.
Due to the nature of the typical gas water heater, the water
temperature in certain situations may vary up to 30F° (16.7 C°)
higher or lower at the point of use such as, bathtubs, showers,
sink, etc.
Never allow small children to use a hot water tap, or to draw
their own bath water. Never leave a child or handicapped person
unattended in a bathtub or shower.
NOTE: A water temperature range of 120°F-140°F (49°C-60°C)
is recommended by most dishwasher manufacturers.
IMPORTANT: Adjusting the thermostat past the 120°F bar on
the temperature dial will increase the risk of scald injury. Hot
water can produce first degree burns within:
Water
Temperature
°F
110(normal shower temp.)
116(pain threshold)
11635 minutes45 minutes
1221 minute5 minutes
1315 seconds25 seconds
1402 seconds5 seconds
1491 second2 seconds
154instantaneous1 second
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)
Time for 1st
Degree Burn
(Less Severe Burns)
FIGURE 21.
Time for Permanent Burns
2nd & 3rd Degree
(Most Severe Burns)
HOTTER WATER CAN SCALD: Water heaters are intended to
produce hot water. Water heated to a temperature which will
satisfy space heating, clothes washing, dish washing, and other
sanitizing needs can scald and permanently injure you upon
contact. Some people are more likely to be permanently injured
by hot water than others. These include the elderly, children,
the infi rm, or physically/mentally handicapped. If anyone using
hot water in your home fi ts into one of these groups or if there is
a local code or state law requiring a certain temperature water
at the hot water tap, then you must take special precautions. In
addition to using the lowest possible temperature setting that
satisfi es your hot water needs, a means such as a mixing valve
should be used at the hot water taps used by these people or
at the water heater. Mixing valves are available at plumbing
supply or hardware stores. Follow manufacturer’s instructions
for installation of the valves. Before changing the factory setting
on the thermostat, see Figures 21 and 22.
GAS CONTROL /
TEMPERATURE KNOB
VAC
IGNITER
FIGURE 22.
120°F
MARK
STATUS
LIGHT
APPROX.
55°F
APPROX.
155°F
NOTE: During low demand periods when hot water is not being
used, a lower thermostat setting will reduce energy losses and
may satisfy your normal hot water needs. If hot water use is
expected to be more than normal, a higher thermostat setting
may be required to meet the increased demand. When leaving
your home for extended periods (vacations, etc.), turn the
temperature dial to the vacation (VAC) setting. This will maintain
the water at low temperatures with minimum energy losses and
prevent the tank from freezing during cold weather.
20
Page 21
Operating the Temperature Control System
Water Temperature Adjustment
The water temperature setting can be adjusted from 55°F
to 155°F. Turn the Gas Control/Temperature Knob to the
desired setting/temperature. See Figure 22 on page 20.
NOTE: The temperatures indicated are approximates. The
actual temperature of the heated water may vary.
Operating Modes and Settings
• Standard Mode - The controller adjusts the water heater
to maintain the temperature set by the user.
• Vacation Setting - The Vacation Setting (VAC) sets
the controller at approximately 55°F. This setting is
recommended when the water heater is not in use for a
long period of time. This effectively turns the controller
temperature setting down to a temperature that prevents
the water in the water heater from freezing while still
conserving energy.
Status Light Codes
Normal Flashes:
0 Flashes Indicates Control Off/Pilot Out.•
1 Flash Indicates Normal Operation.•
Continuous Light indicates the gas control valve/thermostat •
is shutting down.
Diagnostic Flashes: If the water heater is not working, look for
the following diagnostic flashes after lighting the pilot.
2 Flashes Indicates thermopile voltage is low.
4 Flashes Indicates overheat failure.
5 Flashes Indicates water temperature sensor failure.
7 Flashes Indicates electronic control failure.
8 Flashes See “Status Light Code Troubleshooting Chart.”
9 Flashes Indicates chamber temperature sensor circuit
is open or shorted.
10 Flashes Indicates an LDO occurrence was detected in
the combustion chamber (contaminants).
LIST OF STATUS CODES ARE SHOWN
AT TOP OF GAS CONTROL VALVE / THERMOSTAT.
VAC
FIGURE 22B.
STATUS LIGHT
21
Page 22
SERVICE AND ADJUSTMENT
Vent System Inspection
At least once a year, a visual inspection should be made of the
venting system. You should look for:
• Obstructions which could cause improper venting. The
combustion and ventilation air fl ow must not be obstructed.
• Damage or deterioration which could cause improper venting
or leakage of combustion products.
• Rusted fl akes around top of water heater.
Be sure the vent piping is properly connected to prevent
escape of dangerous fl ue gasses which could cause deadly
asphyxiation.
Obstructions and deteriorated vent systems may present serious
health risk or asphyxiation.
Chemical vapor corrosion of the fl ue and vent system may occur
if air for combustion contains certain chemical vapors. Spray can
propellants, cleaning solvents, refrigerator and air conditioner
refrigerants, swimming pool chemicals, calcium and sodium
chloride, waxes, bleach and process chemicals are typical
compounds which are potentially corrosive.
If when inspecting the vent system you find sooting or
deterioration, something is wrong. Call the local gas supplier to
correct the problem and clean or replace the fl ue and venting
before resuming operation of the water heater.
Burner Inspection
Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a fl ooded
water heater will create dangerous conditions which can cause
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
Contact a Sears Service Center to replace a fl ooded water
heater. Do not attempt to repair the unit! It must be replaced!
At least once a year, a visual inspection should be made of the
main burner. See Figure 23.
CORRECT FLAME
SOFT BLUE
FIGURE 23.
Inspect burner fl ames through viewport. Flames should be very
small with a blue haze and small amounts of yellow or orange
at the edges. After several minutes of operation, the burner
screen may glow red. If large fl ames are observed at any time,
shut-off the unit and contact the Sears Service Center.
22
Page 23
Removing the Burner Door Assembly
Ultra Low NOx Natural Gas Burner
1. Turn off the gas to the water heater at the manual
shut-off valve (Figure 2).
2. Turn the gas control/temperature knob to the “OFF”
position (Figure 22).
3. Remove the outer door.
4. Remove the two screws (1/4” nut driver) securing the
burner door assembly to the combustion chamber
(Figure 24).
5. Disconnect the pilot tube (7/16” wrench), the igniter wire
from the igniter lead wire, and manifold tube (3/4” wrench)
at the gas control valve/thermostat. Disconnect the sensor
wires (lift white lever outward, then gently pull the plug
downward). Also, use needle nose pliers to disconnect the
red (+) and white (-) thermopile wires from the gas control
valve/thermostat. See Figures 24 & 25.
GAS CONTROL VALVE/
THERMOSTAT
PIEZO IGNITER BUTTON
VAC
PILOT TUBE
VIEWPORT
OUTER DOOR
NOT SHOWN
BURNER DOOR
SCREWS (2)
TEMPERATURE SENSOR
WIRE CONNECTION
THERMOPILE
WIRE
CONNECTIONS
MANIFOLD TUBE
TEMPERATURE
SENSOR
BURNER DOOR
MANIFOLD COMPONENT BLOCK
FIGURE 24.
Check the burner to see if it is dirty or clogged. The burner may
be cleaned with soft paint brush (Figure 26). Do not use a wire
brush or any tool that may damage the burner screen. Important:
Do not use the burner if the burner screen is damaged. NOTE:
Damage may be rips or holes in the burner screen. Discoloration
is normal.
PILOT ASSEMBLY
BURNER
USE BRUSH ON THIS SURFACE.
FIGURE 26.
Replacing the Pilot/Thermopile Assembly
1. Remove the burner assembly as directed previously.
2.
Lift the retainer clip straight up from the back of the manifold
component block (using a flat-blade screwdriver), then
remove the manifold component block from the burner
door assembly
(Figure 27).
6. Grasp the manifold tube and push down slightly to free the
manifold, pilot tube, and thermopile.
7. Carefully remove the burner door assembly from the burner
compartment.
NOTE: Be sure not to damage internal parts.
SENSOR
WIRES
WHITE
WIRE
(RIGHT
SIDE)
RED
WIRE
(LEFT
SIDE)
IGNITER
BUTTON
IGNITER
LEAD
WIRE
IGNITER
WIRE
VAC
PILOT
TUBE
MANIFOLD
TUBE
FIGURE 25.
IGNITER
WIRE
PILOT TUBE
BURNER DOOR OPENING
THERMOPILE
CONNECTORS
RETAINER
CLIP
MANIFOLD
COMPONENT
BLOCK
FIGURE 27.
3. Locate and remove the phillips screw attaching the pilot to the
pilot bracket,
the igniter wire) out of the burner door assembly.
then pull the pilot/thermopile assembly (including
4. Using a 7/16” wrench, loosen the nut securing the pilot tube to
the pilot assembly (right-hand threads).
5. Pull the pilot tube from the pilot assembly (Figure 28).
IMPORTANT: Be careful not to bend or alter the position of the
pilot assembly components.
23
Page 24
6.
Using the old pilot tube as a guide, bend the new pilot tube
to match the old one. Make only the bends closest to the
pilot before going to the next step.
NOTE: Skip this step if you are reusing the existing
pilot tube.
7. Reconnect the pilot tube and tighten the nut securing it to
the new pilot assembly. To prevent any bending of the pilot
bracket, use pliers to hold the pilot assembly bracket while
tightening the pilot nut. IMPORTANT: Keep the pilot orifice in
the pilot when making the connection. DO NOT operate the
water heater without the pilot orifice installed.
IGNITER CONNECTOR
THERMOPILE
THERMOPILE
CONNECTORS
PILOT TUBE
(FERRULE NUT
NOT SHOWN)
FIGURE 28.
PILOT
PILOT/THERMOPILE
ASSEMBLY
External Inspection & Cleaning of the
Flame Trap
Although not likely to occur, if debris collects on the flame trap
(flame arrestor), use a vacuum, compressed air, or a soft bristle
brush to remove it. NOTE: If unable to inspect or clean the flame
trap from underneath, follow the “Cleaning the Combustion
Chamber and Flame Trap” section instructions.
FLASHLIGHT
MIRROR
FIGURE 29
Cleaning the Combustion Chamber and
Flame Trap
8. Push the new pilot assembly connectors through the opening
in the burner door (See Figure 27).
9. Attach the pilot assembly to the Burner Door Assembly.
10.
Position the new thermopile wires through the top opening of
the manifold component block (Figure 27). Be sure that the
igniter wire is positioned through the middle opening of the
manifold component block. Position the pilot tube through the
bottom opening of the manifold component block.
11. See “Replacing the Burner Door Assembly.”
1. Follow the procedure outlined in “Removing the Burner
Door Assembly” section.
2. Use a vacuum cleaner/shop vac to remove all loose debris
in the combustion chamber (Figure 30). Use compressed
air to clear any dust or debris that may have accumulated
in the flame trap (flame arrestor).
3. Reassemble following the procedure under the “Replacing
the Burner Door Assembly” section.
24
Page 25
Replacing the Burner Door Assembly
Check the door gasket for damage or imbedded debris 1.
prior to installation.
FLAME-TRAP
DOOR GASKET
FIGURE 30.
BRACKET
Piezoelectric Igniter System
The piezoelectric igniter system consists of the igniter
button, electrode, and wire. The pilot is ignited by an electric
spark generated when the igniter button is pressed. (See
Figure 31.) Use only factory authorized piezoelectric igniter
parts for replacement.
THERMOPILE
PILOT
Inspect the viewport for damage and replace as required.2.
Insert the burner assembly into the burner compartment, 3.
making sure that the burner assembly sits firmly against
the burner bracket inside the combustion chamber
(Figure 30).
Inspect the door gasket and make sure there is no 4.
fiberglass insulation between the gasket and the
combustion chamber.
Replace the two screws which secure the burner 5.
assembly to the combustion chamber and tighten
securely. There should be no space between the
gasket part of the burner door and combustion chamber.
IMPORTANT: Do not operate the water heater if the door
gasket does not create a seal between the burner door and
the combustion chamber.
Reconnect the manifold tubing (3/4” wrench), pilot tubing 6.
(7/16” wrench), temperature sensor wires, and thermopile
wires to the gas control valve/thermostat. (See Figure 25
for the correct position of the thermopile wires.) Do not
cross-thread or apply any thread sealant to the fittings.
Reconnect the igniter wire.7.
Turn the gas supply on and refer to “Lighting Instructions” 8.
in the “Operating Instructions” section.
Check for leaks by brushing on an approved noncorrosive 9.
leak detection solution. Bubbles forming indicate a leak.
Correct any leak found. IMPORTANT: All leaks must be
fixed immediately.
Replace the outer door.10.
VAC
ELECTRODE
IGNITER BUTTON
WIRE TO ELECTRODE
FIGURE 31.
PILOT / THERMOPILE BRACKET
(OPPOSITE SIDE)
Testing the Igniter System
Turn off the gas to the water heater at the manual gas shut-off
valve. Watch the electrode tip while activating the igniter. A visible
spark should jump from the electrode. To avoid shock, do not
touch the burner or any metal part on the pilot or pilot assembly.
If no spark is visible, check the wire connections and make sure
the electrode is not broken. Replace the electrode if defective.
NOTE: The electrode is part of the pilot assembly and cannot
be replaced separately. Dirt and rust on the pilot or electrode
tip can prevent the igniter spark. Wipe clean with a damp cloth
and dry completely. Rust can be removed from the electrode
tip and metal surfaces by lightly sanding with an emery cloth or
fi ne grit sandpaper.
25
Page 26
Removing and Replacing the Gas Control
Valve/Thermostat
Removing the Gas Control Valve/Thermostat:
1. Turn the gas control/temperature knob to the “OFF” position
(Figure 22).
2. Turn off the gas at the manual shut-off valve on the gas
supply pipe (Figure 2).
3. Drain the water heater. Refer to the section on “Draining
and Flushing” and follow the procedure.
4. Disconnect the igniter wire from the igniter lead wire.
Disconnect the temperature sensor wire, then use
needle nose pliers to disconnect the red (+) and white (-)
thermopile wires. Disconnect the pilot tube (7/16” wrench)
and manifold tube (3/4” wrench) at the gas control valve/
thermostat (Figure 25).
5. Refer to “Gas Piping” (Figure 2) and disconnect the ground
joint union in the gas piping. Disconnect the remaining pipe
from the gas control valve/thermostat.
6. To remove the gas control valve/thermostat, thread a
4-inch section of gas pipe into the inlet and use it to turn
the gas control valve/thermostat (counterclockwise.) Do
not use a pipe wrench or equivalent to grip body. Damage
may result. Do not insert any sharp objects into the inlet
or outlet connections. Damage to the gas control valve/
thermostat may result.
Replacing the Gas Control Valve/Thermostat:
To replace the gas control valve/thermostat, reassemble in
reverse order. When replacing the gas control valve/thermostat,
thread a 4-inch section of gas pipe into the inlet and use it to turn
the gas control valve/thermostat (clockwise.) DO NOT OVER
TIGHTEN. Damage may result.
• Be sure to use approved Teflon® tape or pipe joint
compound on the gas piping connections and fitting on the
back of the gas control valve that screws into tank.
• Be sure to remove the pilot ferrule nut from the new gas
control valve/thermostat.
• Turn the gas supply on and check for leaks. Test the water
heater by brushing on an approved noncorrosive leak
detection solution. Bubbles forming indicate a leak. Correct
any leak found.
• Be sure tank is completely filled with water before lighting
and activating the water heater. Follow the “Lighting
Instructions” in the “Operating Instructions” section.
• If additional information is required, contact Sears Service
at: 1-800-4-MY-HOME
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.
®
(1-800-469-4663).
Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on
a regular basis.
AT LEAST ONCE EVERY SIX MONTHS, A VISUAL INSPECTION
SHOULD BE MADE OF THE FLAME ARRESTOR. CLEAN IF
LINT ACCUMULATIONS ARE NOTICED.
INSTALLED IN SUITABLE AREA: To ensure suffi cient ventilation
and combustion air supply, proper clearances from the water
heater must be maintained. See Facts to Consider About the Location section. Combustible materials such as clothing,
cleaning materials, or fl ammable liquids, etc. must not be placed
against or adjacent to the water heater because they could
catch on fi re.
Anode Rod Inspection
The anode rod is used to protect the tank from corrosion. Most
hot water tanks are equipped with an anode rod. The submerged
rod deteriorates to protect the tank. Instead of corroding the tank,
water ions attack and eat away the anode rod. This does not
affect the water’s taste or color. The rod must be maintained to
keep the tank in operating condition.
EXPOSED
SUPPORT
WIRE
EXPOSED
SUPPORT
PITTED ANODE ROD
FIGURE 32
Anode deterioration depends on water conductivity, not
necessarily water condition. A corroded or pitted anode rod
indicates high water conductivity and should be checked and/
WIRE
26
Page 27
or replaced more often than an anode rod that appears to be intact.
Replacement of a depleted anode rod can extend the life of your
water heater. Inspection should be conducted by calling the Sears
Service Center for an authorized contractor. The anode rod should
be checked after a maximum of three years of use, then annually
until the condition of the anode rod dictates the replacement of it.
NOTE: Artifi cially softened water requires the anode rod to be
inspected annually.
Temperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually operated
at least once a year.
When checking the temperature-pressure relief valve operation,
make sure that (1) no one is in front of or around the outlet of
the temperature-pressure relief valve discharge line, and (2) that
the water discharge will not cause any property damage, as the
water may be extremely hot, see Figure 33.
FIGURE 33.
If after manually operating the valve, it fails to completely reset
and continues to release water, immediately close the cold water
inlet to the water heater, follow the draining instructions, and
replace the temperature-pressure relief valve with a new one.
If the temperature-pressure relief valve on the appliance weeps
or discharges periodically, this may be due to thermal expansion.
You may have a check valve installed in the water line or a water
meter with a check valve. Consult the Sears Service Center
for further information. Do not plug the temperature-pressure
relief valve.
Draining
It is recommended that the tank be drained and fl ushed every 6
months to remove sediment which may build up during operation.
The water heater should be drained if being shut down during
freezing temperatures. To drain the tank, perform the following
steps:
Turn off the gas to the water heater at the manual gas 1.
shut-off valve.
Open a nearby hot water faucet until the water is no longer hot.2.
Close the cold water inlet valve.3.
Connect a hose to the drain valve and terminate it to an 4.
adequate drain or external to the building.
Open the water heater drain valve and allow all of the water 5.
to drain from the tank. Flush the tank with water as needed
to remove sediment.
Close the drain valve, refi ll the tank, and restart the heater 6.
as directed in this manual.
If the water heater is going to be shut down for an extended
period, the drain valve should be left open.
IMPORTANT: Condensation may occur when refi lling the tank
and should not be confused with a tank leak.
Follow the lighting instructions in the Lighting section to restart
the water heater.
Drain Valve Washer Replacement
(See Figure 34)
1. Turn “OFF” gas supply to water heater.
2. Follow “Draining” instructions.
3. Turning counter clockwise (
4. Unscrew the stem by turning it counter clockwise (
remove it from the drain valve body.
5. Remove the bottom washer and put the new one in place.
6. Re-insert the stem into the drain valve body and retighten the
cap to the body using a wrench. DO NOT OVER TIGHTEN.
7. Follow instructions in the Filling The Water Heater section.
8. Check for leaks.
9. Follow the lighting instructions in the Lighting section to restart
the water heater.
WASHER
STEM
WASHER
FIGURE 34.
), remove the cap.
), and
CAP
Service
Before calling for repair service, read the Start Up Conditions
and Operational Conditions found in the Troubleshooting Guide
of this manual.
If a condition persists or you are uncertain about the operation of
the water heater, let the Sears Service Center check it out.
Contact Sears Service Center at:
1-800-4-MY-HOME
27
®
(1-800-469-4663).
Page 28
TROUBLESHOOTING GUIDE
Start Up Conditions
Thermal Expansion
As water is heated, it expands (thermal expansion). In a closed
system, the volume of water will grow. As the volume of water
grows, there will be a corresponding increase in water pressure
due to thermal expansion. Thermal expansion can cause
premature tank failure (leakage). This type of failure is not
covered under the limited warranty. Thermal expansion can also
cause intermittent temperature-pressure relief valve operation:
water discharged from the valve due to excessive pressure build
up. The temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This condition is not covered
under the limited warranty.
A properly-sized thermal expansion tank should be installed
on all closed systems to control the harmful effects of thermal
expansion. Contact a plumbing service agency or your retail
supplier regarding the installation of a thermal expansion tank.
Table 1: Thermal Expansion Tank Specifi cations
Model
Number
153.33102028 (203 mm) 12-3/4 (323 mm) 3/4” Male
153.331050511 (279 mm) 14-3/4 (375 mm) 3/4” Male
Tank
Capacity
In Gallons
Dimensions
in Inches
Pipe
Fitting
On TankDiameterLength
Table 2: Expansion Tank Sizing Chart
Inlet*
Water
Pressure
Expansion
Tank
Capacity
Needed
40 psi22255
50 psi22255
60 psi22255
70 psi22555
80 psi25555
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE: Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi,
the expansion tank’s air pressure must be adjusted to
match that pressure, but must not be higher than 80 psi.
Water Heater Capacity (Gallons)
3040506682
FIGURE 35.
Strange Sounds
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area
during heating and cooling periods and should be considered
normal. See Condensation section.
Draft Hood Operation
WARNING
Burn Hazard
Do not touch vent.
Doing so can result in burns.
Check draft hood operation by performing a worst case
depressurization of the building. With all doors and windows closed,
and with all air handling equipment and exhaust fans operating
such as furnaces, clothes dryers, range hoods and bathroom fans,
a match fl ame should still be drawn into the draft hood of the water
heater with its burner fi ring. If the fl ame is not drawn toward the draft
hood after 15 minutes of burner operation, shut off water heater
and make necessary air supply changes to correct.
28
Page 29
Condensation
Whenever the water heater is fi lled with cold water, some
condensate will form while the burner is on. A water heater may
appear to be leaking when in fact the water is condensation. This
usually happens when:
• A new water heater is fi lled with cold water for the fi rst time.
• Burning gas produces water vapor In water heaters,
particularly high effi ciency models where fl ue temperatures
are lower.
• Large amounts of hot water are used in a short time and the
refi ll water in the tank is very cold.
Moisture from the products of combustion condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a “sizzling” or
“frying” noise.
Excessive condensation can cause pilot outage due to water
running down the fl ue tube onto the main burner and putting
out the pilot.
Because of the suddenness and amount of water, condensation
water may be diagnosed as a “tank leak”. After the water in
the tank warms up (about 1-2 hours), the condition should
disappear.
Do not assume the water heater is leaking until there has been
enough time for the water in the tank to warm up.
An undersized water heater will cause more condensation.
The water heater must be sized properly to meet the family’s
demands for hot water including dishwashers, washing machines
and shower heads.
Excessive condensation may be noticed during the winter and
early spring months when incoming water temperatures are at
their lowest.
Good venting is essential for a gas fi red water heater to operate
properly as well as to carry away products of combustion and
water vapor.
lines. Contact Sears Service for further information concerning
an Anode Replacement Kit #9001453 and this Chlorination
Treatment. Anode replacement and chlorination of the tank are
not covered by the water heater’s limited warranty.
If the smelly water persists after the anode replacement and
chlorination treatment, it may be necessary to chlorinate or aerate
your water supply to eliminate the problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
Water Temperature Stacking
Stacking occurs when a series of short draws of hot water
(3 gallons or less) are taken from the water heater tank. This
causes increased cycling of the burner and can result in
increased water temperatures at the hot water outlet.
This water heater’s temperature control has been designed
to accurately regulate the water temperature. However,
under certain operating conditions, the water temperature
may temporarily exceed the dial setting. Consequently, in
addition to setting the temperature no higher than 120°F,
we recommend the installation of a mixing valve or an
anti-scald device in the hot water supply line or at the point of use
to further reduce the risk of scald injury. These devices can be
obtained from a plumbing service agency or your retail supplier.
“AIR” In Hot Water Faucets
Smoke Odor
It is not uncommon to experience a small amount of smoke and
odor during the initial start-up. This is due to burning off of oil
from metal parts, and will disappear in a short while.
Operational Conditions
Smelly Odor
In each water heater there is installed at least one anode rod (see
parts section) for corrosion protection of the tank. Certain water
conditions will cause a reaction between this rod and the water.
The most common complaint associated with the anode rod is
one of a “rotten egg smell”. This odor is derived from hydrogen
sulfi de gas dissolved in the water. The smell is the result of four
factors which must all be present for the odor to develop:
• a concentration of sulfate in the supply water.
• little or no dissolved oxygen in the water.
• a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
• an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
fl ammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet,
located farthest away, be opened for several minutes before
any electrical appliances which are connected to the hot water
system are used (such as a dishwasher or washing machine).
If hydrogen gas is present, there will probably be an unusual
sound similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open fl ame near
the faucet at the time it is open.
Safety Shut-Off
This water heater is equipped with an automatic gas shutoff
system. This system works when high water temperatures are
present. The high temperature shutoff is built into the gas control
valve. It is non-resettable. If the high temperature shutoff activates,
the gas control valve must be replaced. Turn “OFF” the entire gas
supply to the water heater and contact your gas supplier.
This water heater is designed to automatically shut-off in the
event of the following:
1. The pilot flame is extinguished for any reason.
29
Page 30
2. The water temperature exceeds 189°F (87°C).
6” MAXIMUM
AIR GAP
AC
B
D
E
F
G
H
I
3. Excessive contaminants in the combustion chamber.
4. The ignition of flammable vapors.
A thermopile is used to determine if a pilot fl ame is present and
will shut off the gas supply to the main burner and pilot if the
fl ame is absent. This unit is also equipped with a combustion
chamber temperature sensor. This sensor will shut off the gas
supply to the burner if lint, dust, or other contaminants pollute
the burner. If the gas control valve/thermostat shuts off the gas
supply, check the diagnostic fl ash code and refer to the “Status
Light Troubleshooting Chart.” If necessary, also refer to the
“Troubleshooting Guide.”
Also, a temperature limit switch or ECO (Energy Cut Off) sensor
located in the gas control valve\thermostat is used to shut
off the water heater if the water temperature exceeds 189°F
(87°C). The Diagnostic Status Light will flash a code indicating
an “Overheat Failure” (4 Flashes). See “Operating the
Temperature Control System.” If the ECO has functioned, the
gas control valve/thermostat should be replaced by a qualified
technician. Contact Sears Service for service information.
If the Diagnostic Status Light indicates an “LDO Occurrence”
(10 Flashes), refer to the “Status Light Troubleshooting Chart.”
Read this manual fi rst. Then, before checking the water heater,
make sure the gas supply has been turned “OFF”, and never
turn the gas “ON” before the tank is completely full of water.
Never use this water heater unless it is completely fi lled with
water. To prevent damage to the tank, the tank must be fi lled
with water. Water must fl ow from the hot water faucet before
turning “ON” gas to the water heater.
A. Water at the draft hood is water vapor which has
condensed out of the combustion products. This is
caused by a problem in the vent. Contact a qualifi ed
technician.
Leakage Checkpoints
B. *Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
C. *The anode rod fi tting may be leaking.
D. Small amounts of water from temperature-pressure relief
valve may be due to thermal expansion or high water
pressure in your area.
E. *The temperature-pressure relief valve may be leaking at
the tank fi tting.
F. Water from a drain valve may be due to the valve being
slightly opened.
G. *The drain valve may be leaking at the tank fi tting.
H. Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets
form and drip onto the burner or run on the fl oor. This is
common at the time of start-up after installation and when
incoming water is cold.
I. Water in the water heater bottom or on the fl oor may be
from condensation, loose connections, or the relief valve.
DO NOT replace the water heater until a full inspection
of all possible water sources is made and necessary
corrective steps taken.
FIGURE 36.
Leakage from other appliances, water lines, or ground
seepage should also be checked.
* To check where threaded portion enters tank, insert cotton
swab between jacket opening and fi tting. If cotton is wet,
follow draining instructions in the “Draining” section and then
remove fi tting. Put pipe dope or tefl on tape on the threads
and replace. When you are fi nished, follow the steps in
“Filling the Water Heater” in the Installation Instructions
earlier in this manual.
30
Page 31
TROUBLESHOOTING GUIDE
PROBLEMPOSSIBLE CAUSE(S)CORRECTIVE ACTION
BURNER WILL NOT IGNITE1. Pilot not lit
SMELLY WATER1. Sulfides in the water1. Replace the anode with a special anode
BURNER FLAME YELLOWLAZY
PILOT WILL NOT LIGHT OR
REMAIN LIT
HIGH OPERATION COSTS1. Thermostat set too high
INSUFFICIENT HOT WATER 1. Thermostat set too low
SLOW HOT WATER
RECOVERY
2. Thermostat set too low
3. No gas
4. Dirt in the gas lines
5. Pilot line clogged
6. Main burner line clogged
7. Non-functioning thermopile
8. Non-functioning thermostat
9. Heater installed in a confined area
1. Insufficient secondary air
2. Low gas pressure
3. Flue clogged
4. Main burner line clogged
5. Heater installed in a confined area
6. Obstruction in main burner orifice
1. Non-functioning igniter
2. Thermopile connection loose
3. Air in gas line
4. Proper Lighting Sequence not followed.
Gas Control / Temperature Knob was not
held in for sufficient time.
5. Low gas pressure
6. No gas
7. Dirt in gas lines
8. Cold drafts
9. ECO switch open
10. Pilot line or orifice clogged
11. Non-functioning thermopile
12. Air for combustion obstructed
13. Flammable vapors incident, FVIR function
utilized
2. Sediment or lime in tank
3. Water heater too small for job
4. Wrong piping connections
5. Leaking faucets
6. Gas leaks
7. Wasted hot water
8. Long runs of exposed piping
9. Hot water piping in exposed wall
2. Sediment or lime in tank
3. Water heater too small
4. Wrong piping connections
5. Leaking faucets
6. Wasted hot water
7. Long runs of exposed piping
8. Hot water piping in outside wall
9. Low gas pressure
1. Insufficient secondary air
2. Flue clogged
3. Low gas pressure
4. Improper calibration
5. Thermostat set too low
6. Water heater too small
7. Wrong piping connections
8. Wasted hot water
1. Light pilot
2. Turn temp. dial to desired temperature
3. Check with gas utility company
4. Notify utility-install trap in gas line
5. Clean, locate source and correct
6. Clean, locate source and correct
7. Replace thermopile
8. Replace thermostat
9. Provide fresh air ventilation
1. Provide ventilation to water heater
2. Check with gas utility company
3. Clean, locate source and correct
4. Clean, locate source and correct
5. Proper fresh air ventilation
6. Clean or replace orifice
1. Replace igniter pilot assembly
2. Seat connector firmly in socket
3. Bleed the air from the gas line
4. Do not attempt to relight if the red light is
lit and the pilot flame is not visible through
the view port. Wait until the red light is no
longer lit, then follow lighting instructions
on the water heater.
5. Check with gas utility company
6. Check with gas utility company
7. Notify utility-install dirt trap in gas line
8. Locate source and correct
9. Replace gas control valve/thermostat
10. Clean, locate source and correct
11. Replace thermopile
12. See maintenance section for inspection
and cleaning of flame trap
13. Eliminate flammable vapor source(s),
Call 1-800-4-MY-HOME
1. Set temperature dial to lower setting
2. Drain/flush-provide water treatment
if needed
3. Install adequate heater
4. Correct piping-dip tube must be in
cold inlet
5. Repair faucets
6. Check with utility-repair at once
7. Advise customer
8. Insulate piping
9. Insulate piping
1. Turn temperature dial to desired setting
2. Drain/flush-provide water treatment if
needed
3. Install adequate heater
4. Correct piping-dip tube must be in cold
inlet
5 Repair faucets
6. Advise customer
7. Insulate piping
8. Insulate piping
9. Check with gas utility company
1. Provide ventilation to water heater. Check
flue way, flue baffle, and burner
2. Clean flue, locate source and correct
3. Check with gas utility company
4. Replace thermostat
5. Turn temperature dial to desired setting
6. Install adequate heater
7. Correct piping-dip tube must be in cold
inlet
8. Advise customer
®
(1-800-469-4663)
31
Page 32
TROUBLESHOOTING GUIDE (Continued)
DRIP FROM RELIEF VALVE1. Excessive water pressure
2. Heater stacking
3. Closed water system
THERMOSTAT FAILS TO
SHUT-OFF
COMBUSTION ODORS1. Insufficient secondary air
SMOKING AND CARBON
FORMATION (SOOTING)
CONDENSATION1. Temperature setting too low1. Increase the temperature setting
BURNER FLAME FLOATS
AND LIFTS OFF PORTS
BURNER FLAME TOO HIGH 1. Orifice too large1. Replace with correct orifice
PILOT FLAME
TOO SMALL
1. Thermostat not functioning properly
2. Improper calibration
2. Flue clogged
3. Heater installed in a confined area
1. Insufficient secondary air
2. Low gas pressure
3. Flue clogged
4. Thermostat not functioning properly
5. Heater installed in a confined area
6. Burner flame yellow-lazy
1. Orifice too large
2. High gas pressure
3. Flue clogged
4. Cold drafts
1. Pilot line or orifice clogged
2. Low gas pressure
1. Use a pressure reducing valve and relief
valve
2. Lower the thermostat setting
3. See “Closed System/Thermal Expansion”
1. Replace thermostat
2. Replace thermostat
1. Provide ventilation to water heater. Check
flue way, flue baffle, and burner
2. Clean, locate source and correct
3. Provide fresh air ventilation
1. Provide ventilation to water heater. Check
flue way, flue baffle, burner
2. Check with gas utility company
3. Clean, locate source and correct
4. Replace thermostat
5. Provide fresh air ventilation
6. See “Burner Flame Yellow-Lazy”
1. Replace with correct orifice
2. Check with gas utility company
3. Clean flue and burner-locate source and
correct
4. Locate source and correct
1. Clean, locate source and correct
2. Check with gas utility company
32
Page 33
STATUS LIGHT TROUBLESHOOTING CHART
LED STATUSPROBLEMCORRECTIVE ACTION
0 FLASHES (LED NOT LIT)Pilot light is not lit. Not enough
5 FLASHESWater temperature sensor failureReplace the gas control valve/thermostat. If
7 FLASHESGas Control Valve/Thermostat
failure.
8 FLASHESThis condition only appears if the
gas control/temperature knob has
been turned off and the thermopile
continued to produce electric
power. This condition can occur
if the thermopile does not cool
down as quickly as expected when
the unit is shut off. This condition
can also occur if the gas control/
temperature knob has been turned
off and the pilot continues to
operate because the pilot valve is
stuck in the open position.
9 FLASHESCombustion chamber temperature
sensor circuit is open or shorted
10 FLASHESLDO occurrence was detected
in the combustion chamber
(contaminants)
Follow the lighting instructions on the front of
the water heater and record any diagnostic
codes. See Status Light Codes section.
Check all wiring connections. If problem 1.
persists proceed to step 2.
Replace the thermopile. 2. If you feel
uncomfortable with this procedure,
contact a qualifi ed technician.
Replace the gas control valve/thermostat. If
you feel uncomfortable with this procedure,
contact a qualifi ed technician.
you feel uncomfortable with this procedure,
contact a qualifi ed technician.
Replace the gas control valve/thermostat. If
you feel uncomfortable with this procedure,
contact a qualifi ed technician.
Make sure that the gas control valve/
thermostat knob is set to OFF. Wait one
minute. Remove the outer door. Look through
the sight glass for a pilot fl ame. If a pilot fl ame is observed with the gas control valve/
thermostat knob set to the OFF position, the
pilot valve is stuck open. Turn the main gas
supply OFF. Replace the gas control valve/
thermostat. If you feel uncomfortable with this
procedure, contact a qualifi ed technician.
If the pilot fl ame is not observed when the gas
control valve/thermostat knob is set to the OFF
position, wait 10 minutes for the thermopile
to cool, then attempt to relight the pilot by
following the lighting instructions on the water
heater’s label. If this condition returns, replace
the gas control valve/thermostat. Contact a
qualifi ed technician if you are uncomfortable
with this procedure.
Check all connections. If the problem 1.
persists, proceed to step 2.
Replace the temperature sensor. 2. If you
feel uncomfortable with this procedure,
contact a qualifi ed technician. If the
problem persists, proceed to step 3.
Replace the gas control valve/thermostat. 3.
If you feel uncomfortable with this
procedure, contact a qualifi ed technician.
Reset the system by following these steps: 1.
1.) Turn the temperature adjustment knob
to OFF. 2.) Unplug the thermopile plug
from the gas control valve/thermostat. 3.)
Wait for about three minutes. 4.) Plug
the thermopile plug back into the gas
control valve/ thermostat. 5.) Turn the
temperature adjustment knob to PILOT
and restart the water heater as directed
in this manual. If the problem persists,
proceed to step 2.
Follow the procedure outlined in “Cleaning 2.
the Combustion Chamber and FlameTrap.” If the problem persists, proceed to
step 3.
Shut off the gas supply to the water heater 3.
and contact Sears Service:
1-800-4-MY-HOME ® (1-800-469-4663).
33
Page 34
PILOT LIGHT TROUBLESHOOTING CHART
Section A: Pilot light will not light (new installation).
Is the manual gas shut-off valve,
located in the supply line to the
water heater, in the on position?
YES
Have you bled all the air
from the pilot tube and
gas supply line?
YES
Is the igniter producing a
spark?
NO
Follow the “Testing the Igniter
System” section in this manual.
NO
YES
Turn the manual gas shut-off valve to
the on position and follow the lighting
NO
instructions on the front of the water heater.
While repeatedly depressing the igniter
button, push in and hold the gas control/
temperature knob until the pilot is lit and
maintains a stable flame, (status light
will blink) then release the gas control/
temperature knob.
Set thermostat to desired temperature.
Section B: Pilot light repeatedly goes out.
Remove the burner door
assembly. Are the flame-trap and
burner free from debris due to
excessive lint, dirt, dust or oil?
YES
Refer to the “Maintenance of
your Water Heater” section of this
NO
manual for information on cleaning
the flame-trap and burner.
Section C: Pilot light will not remain lit.
Check for insufficient combustion air.
Are the combustion air supply and ventilation openings
of sufficient size? See “Combustion Air Supply and
Ventilation” section in this manual for requirements.
YES
Is there a furnace/air handler in the same room as the water heater?
NO
YES
Does the return air duct for the furnace/
air handler draw its air from a separate
location than the water heater? Refer to
the “Installation Instructions” section of
this manual.
YES
Is there proper drafting at the
drafthood? See “Draft Hood
Operation” section of manual.
YES
Contact Sears Service at
1-800-4-MY-HOME
®
(1-800-469-4663).
NO
Contact a local Heating,
Ventilation, Air-Conditioning
NO
& Refrigeration authorized
service provider to correct
the combustion air supply/
ventilation issue.
Check the vent
system for restrictions/
obstructions and check
the vent termination
height. Refer to the
“Installation Instructions”
section of this manual for
specific requirements.
NO
Correct size of
openings to allow
sufficient air.
Does the flame-trap
show signs of
discoloration?
YES
Shut-off the gas supply to the water heater at
the manual gas shut-off valve, then contact Sears
Service at 1-800-4-MY-HOME
NO
Go to section C.
Reassemble the heater and attempt to
NO
return the heater to service. Does the
pilot remain lit?
®
(1-800-469-4663)
Set to desired temperature.
Does the diagnostic status light on the
gas control valve/thermostat give
a two flash error code?
Refer to the “Replacing the Pilot/Thermopile
Assembly” instructions in the manual.
Reassemble and restore to service.
YES
NO
YES
NOTE: If you are still experiencing difficulties after
* Not Shown.
** Includes Inner Door Gasket
*** Flexible manifold tube sold as a separate part (burner not included).
14
17
9
Model Numbers
Now that you have purchased your gas water heater, should a need
ever exist for repair parts or service, simply contact any Sears Service
Center or call 1-800-4-MY-HOME® (1-800-469-4663). Be sure to
provide all pertinent facts when you call or visit.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
• MODEL NUMBER
• SERIAL NUMBER
• TYPE GAS - NATURAL
• PART DESCRIPTION
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.
35
Page 36
Get it fixed, at your home or ours!
Your Home
For troubleshooting, product manuals and expert advice:
www.managemylife.com
For repair – in your home – of all major brand appliances,
lawn and garden equipment, or heating and cooling systems,
no matter who made it, no matter who sold it!
For the replacement parts, accessories and
owner’s manuals that you need to do-it-yourself.
For Sears professional installation of home appliances
and items like garage door openers and water heaters.
1-800-4-MY-HOME
Call anytime, day or night (U.S.A. and Canada)
www.sears.com www.sears.ca
®
(1-800-469-4663)
Our Home
For repair of carry-in items like vacuums, lawn equipment,
and electronics, call anytime for the location of your nearest
Sears Parts & Repair Service Center
1-800-488-1222 (U.S.A.) 1-800-469-4663 (Canada)
www.sears.com www.sears.ca
To purchase a protection agreement on a product serviced by Sears:
1-800-827-6655 (U.S.A.) 1-800-361-6665 (Canada)
Para pedir servicio de reparación
a domicilio, y para ordenar piezas:
1-888-SU-HOGAR
(1-888-784-6427)
www.sears.com
®
Au Canada pour service en français:
1-800-LE-FOYER
(1-800-533-6937)
www.sears.ca
MC
® Registered Trademark / TM Trademark of KCD IP, LLC in the United States, or Sears Brands, LLC in other countries
® Marca Registrada /
MC
Marque de commerce / MD Marque déposée de Sears Brands, LLC
TM
Marca de Fábrica de KCD IP, LLC en Estados Unidos, o Sears Brands, LLC in otros países
36