Kemppi M 420MV User Manual

FastMig
M 420MV
Operating manual
Brugsanvisning
Manual de instrucciones
Manual de utilização
EN
NO
ES
OPERATING MANUAL
English
EN
CONTENTS
1. Introduction ......................................................................................................................... 3
1.1 General ....................................................................................................................................... 3
1.2 About FastMig M 420MV ..................................................................................................... 4
1.2.1 Operation control and connectors ................................................................................. 4
1.3 Accessories ................................................................................................................................ 4
1.3.1 Remote control devices ................................................................................................... 4
1.3.2 Cables ............................................................................................................................... 5
2. Installation ............................................................................................................................. 6
2.1 Positioning of the machine ................................................................................................ 6
2.2 Distribution network ............................................................................................................. 6
2.3 Connection to the mains supply ...................................................................................... 7
2.4 Welding and earth return cables ...................................................................................... 7
3. Operation controls ........................................................................................................... 8
3.1 Main switch I/O ....................................................................................................................... 8
3.2 Pilot lamps ................................................................................................................................. 8
3.3 Operation of cooling fan ..................................................................................................... 8
4. Manual metal arc welding .......................................................................................... 8
5. Maintenance ........................................................................................................................ 9
5.1 Daily maintenance ................................................................................................................. 9
5.2 Periodic maintenance ........................................................................................................... 9
5.3 Service Workshop maintenance ....................................................................................... 9
6. Operation disturbances .............................................................................................10
7. Disposal of the machine ............................................................................................10
8. Ordering numbers .........................................................................................................11
9. Technical data ...................................................................................................................12
2
FastMig M 420MV
1. INTRODUCTION
1.1 General
Congratulations on choosing the FastMig welding equipment. Used correctly, Kemppi products can signicantly increase the productivity of your welding, and provide years of economical service.
This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specications of the equipment can be found at the end of the manual.
Please read the manual carefully before using the equipment for the rst time. For your own safety and that of your working environment, pay particular attention to the safety instructions in the manual.
For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi dealer, or visit the Kemppi web site at www.kemppi.com.
The specications presented in this manual are subject to change without prior notice.
Important notes
Items in the manual that require particular attention in order to minimise damage and personal harm are indicated with the ’NOTE!’ notation. Read these sections carefully and follow their instructions.
Disclaimer
While every eort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specication of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi.
EN
© Kemppi Oy / 1515
3
1.2 About FastMig M 420MV
FastMig M 420MV is multi-operator power source designed for demanding professional use. It is suitable for MMA and MIG welding in DC.
1.2.1 Operation control and connectors
2.
8.
EN
4.
3.
7.
6.
1. Fuse (delayed 6.3 A)
2. Signal lamp
3. Warning lamp for thermal protection
4. Main switch
5. Welding connection
6. Earth connection
7. Control cable connection
8. Inlet of mains cable
1.3 Accessories
1.3.1 Remote control devices
6,3A
5.
1.
7.
4
R10
R20
MIG-MAG remote control device with controls for wire feed and voltage, memory scales 1 … 5. You can use control device also for control of MMA current.
FastMig M 420MV
1. Control of MMA/TIG welding current, reference scale 1 … 5.
1.
1.
2.
1. Wire feed adjustment, electrode current adjustment.
2. Voltage adjustment.
1.3.2 Cables
NOTE ! Always check before use that the mains cable, earth return cable and its clamp,
interconnection cable and shielding gas hose are in a serviceable condition. Ensure that connectors are correctly fastened. Loose connectors can impair welding performance and damage connectors.
Liquid-cooled system: FastMig power source + MXF + FastCool 10
5.
.
4
10.
8.
1. MXF wire feed unit
2. FastMig power source
3. FastCool water cooler and power connection
4. Gas supply
5. MMA electrode holder
6. Remote control device
7. Liquid cooled welding Gun
8. Power cable
9. Earth return cable and clamp
10. Control cable
6.
1.
7.
2.
EN
3.
9.
© Kemppi Oy / 1515
5
Air-cooled system: FastMig power source + MXF
4
.
EN
3.
9.
7
.
1. MXF wire feed unit
2. FastMig power source
3. Gas supply
4. MMA electrode holder
5. Remote control device
6. Air cooled welding Gun
7. Power cable
8. Earth return cable and clamp
9. Control cable
5.
1.
.
6
2.
8.
2. INSTALLATION
2.1 Positioning of the machine
Place the machine on a rm, dry and level surface. Where possible, do not allow dust or other impurities to enter the machines cooling air ow. Preferably site the machine above oor level; for example on a suitable carriage unit.
Notes for positioning the machine
• The surface inclination should not exceed 15 degrees.
• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in
front of and behind the machine for cooling air to circulate.
• Protect the machine against heavy rain and direct sunshine.
NOTE! The machine should not be operated in the rain as the protection class of the machine,
IP23S, allows for outside preserving and storage only.
NOTE! Never aim metallic grinding spray/sparks towards the equipment.
2.2 Distribution network
All regular electrical devices without special circuits generate harmonic currents into distribution network. High rates of harmonic current may cause losses and disturbance to some equipment.
This equipment complies with IEC 61000-3-12 provided that the short-circuit power Ssc is greater than or equal to 5.6 MVA at the interface point between the user’s supply and the public supply network. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment is connected only to a supply with a short-circuit power Ssc greater than or equal to 5.6 MVA.
NOTE! The above applies only when connected to the mains supply of 380...440 V 3~.
6
FastMig M 420MV
2.3 Connection to the mains supply
FastMig power sources are delivered equipped with 5 m mains cable without plug. If local electricity regulations of operating country are stating otherwise, the mains cable
should be replaced in conformity with the local regulations. Connection of the mains cable, mounting and change of the plug should only be carried out
by a competent electrician. Remove the machine’s right side plate to enable the mounting of a mains cable. M 420MV power source can be connected to the mains supply of 220...230 V 3~ or 380...440 V
3~ .
If changing the mains cable take into consideration the following:
The cable is entered into the machine through the inlet ring on the rear panel of the machine and fastened with a cable clamp (05). The phase conductors of the cable are coupled to connectors L1, L2 and L3. The earth protection coloured green-yellow is coupled to connector.
NOTE! If you are using 5-lead cable, do not connect neutral conductor.
EN
Sizes of the mains cables and fuse ratings for the machine at 100 % duty cycle are specied in the table below:
Rated voltage Fuses, slow-blow Connection cable *) mm²
380...440 V 3~ 35 A H07RN-F 4G10 (10 mm²)
220...230 V 3~ 50 A H07RN-F 4G10 (10 mm²)
*) In cables of S type there is a protective grounding conductor coloured green-yellow.
2.4 Welding and earth return cables
Recommended copper cables with cross-sectional area are as follows: FastMig M 420MV 70 ... 95 mm² In enclosed table are shown typical load capacities of rubber insulated copper cables, when
ambient temperature is 25º C and lead temperature is 85º C.
Cable Duty cycle ED Voltage loss / 10 m
100 % 60 % 30 % 50 mm² 285 A 370 A 520 A 0,35 V / 100 A 70 mm² 355 A 460 A 650 A 0,25 V / 100 A 95 mm² 430 A 560 A 790 A 0,18 V / 100 A
Do not overload welding cables due to voltage losses and heating.
NOTE ! Always check the serviceability of the earth return cable and clamp. Ensure the metal
surface to which the cable is connected is clean from metal oxide or paint. Check the connector to the power source is fastened correctly.
© Kemppi Oy / 1515
7
3. OPERATION CONTROLS
3.1 Main switch I/O
When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and the machine is ready for use.
NOTE! Always turn the machine on and o with the mains switch, never use the mains plugs as a
switch.
3.2 Pilot lamps
The pilot lamps of the machine report the electric operation: The green pilot lamp H11 when lit indicates that the machine is on and ready for use and it is
connected to the mains supply with the main switch in the I-position. H12 indicates when lit that the thermal protection of the machine has been activated due to
over heating. The cooling fan will continue to run and cool the machine down and when the lamp is o the machine is ready to weld.
EN
3.3 Operation of cooling fan
In FastMig power sources there are two simultaneously operating fans.
• The fan is started for a moment when main switch is placed into position I.
• The fan will start during welding as the machine heats up and it will run for 1 to 10
minutes after the welding has stopped.
4. MANUAL METAL ARC WELDING
The FastMig power source can be used in electrode welding by connecting a FastMig MXF 63, MXF 65 or MXF 67 wire feeder to it. The power source can be made suitable for electrode welding without a wire feeder by connecting an R10 or R20 remote control to the X14 or X15 terminal at the back of the power source for welding current adjustment, and the welding power cable connected to the power source’s (+) connector X11 or X12.
8
FastMig M 420MV
5. MAINTENANCE
When considering and planning routine maintenance, please consider the frequency of machine use and the working environment.
Correct operation of the machine and regular maintenance will help you avoid unnecessary downtime and equipment failure.
NOTE! Disconnect the machine from the mains before handling the electrical cables.
5.1 Daily maintenance
• Check the overall condition of the welding gun. Remove welding spatter from the contact tip and clean the gas nozzle. Replace worn or damaged parts. Only use original Kemppi spare parts.
• Check the condition and connection of the welding circuit components: welding gun, earth return cable and clamp, sockets and connectors.
• Check the condition of the feed rolls, needle bearings and shafts. Clean and lubricate bearings and shafts with a small quantity of light machine oil if necessary. Assemble, adjust and test function.
• Check that the feed rolls are suitable for the ller wire you are using, and that their pressure adjustment is correct.
5.2 Periodic maintenance
NOTE! Periodic maintenance should only be carried out by a suitably qualied person. Disconnect
the plug of the machine from the mains socket and wait about 2 minutes (capacitor charge) before removing the cover plate.
Check at least every half year:
• Electric connectors of the machine – clean any oxidized parts and tighten loose connections.
NOTE! You must know the correct tension torques values before starting the reparation of the loose
joints.
Clean the inner parts of the machine from dust and dirt e.g. with a soft brush and vacuum cleaner. Also clean the ventilation net behind the front grill.
Do not use compressed air, there is a risk that the dirt will compact even more tightly into gaps of cooling proles.
Do not use pressure washing devices. Only an authorized trained electrician should carry out repairs to Kemppi machines.
EN
5.3 Service Workshop maintenance
Kemppi Service Workshops complete maintenance according to their Kemppi service agreement.
The major points in the maintenance procedure are listed as follows:
• Cleaning of the machine
• Checking and maintenance of the welding tools
• Checking of connectors, switches and potentiometers
• Checking of electric connections
• Checking of mains cable and plug
• Damaged parts or parts in bad condition are replaced by new ones
• Maintenance testing.
• Operation and performance values of the machine are checked, and when necessary
adjusted by means of software and test equipment.
Software loading
• Kemppi Service Workshops can also test and load rmware and welding software.
© Kemppi Oy / 1515
9
EN
6. OPERATION DISTURBANCES
Should you experience a malfunction from your machine, please consult the basic troubleshooting text above rst, and complete some basic checks.
If the machine malfunction cannot be corrected with these measures, contact your Kemppi maintenance service workshop.
Operation of the overload protection
Yellow thermal protection lamp is lit when the thermostat is operating due to loading beyond the stated duty cycle.
The thermostat will operate, if machine is continuously loaded over rated values or cooling air circulation is blocked.
Internal fans will cool the machine, and when the pilot lamp is not lit the machine is automatically ready for welding.
Control fuses
Fuse, 6.3 A delayed, on the rear wall of machine provides protection for auxiliary devices. Use the same type and rating of fuse as marked beside the fuse adapter. Damage caused by
incorrect fuse selection is not covered by the guarantee.
Under and over voltages in the mains supply
Primary circuits of the machine are protected against sudden, transient overvoltages. The machine is designed to withstand 3 x 440 V voltage continuously. Ensure that voltage is kept within this permissible limit, especially when the mains supply is provided by a combustion engine generator. If the mains has under voltage or overvoltage, machine control stops operation automatically.
Loss of a phase in the mains supply
Loss of a mains power phase causes noticeably poor welding properties. In some cases the machine won't start at all. Loss of a phase can be due to following:
• Blowing of mains supply fuse
• Defective mains cable
• Bad connection of mains power cable on machine terminal block or plug of machine.
7. DISPOSAL OF THE MACHINE
Do not dispose of electrical equipment with normal waste! In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and taken to an appropriate environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
10
FastMig M 420MV
8. ORDERING NUMBERS
FastMig M 420MV
6132423
Wire feeders
MXF 65 EL To be used with MS panels 6152100EL MXF 67 EL To be used with MS panels 6152200EL MXF 63 EL To be used with MS panels 6152300EL MXF 65 To be used with MR panels 6152100 MXF 67 To be used with MR panels 6152200 MXF 63 To be used with MR panels 6152300
Panels for wire feeders
FastMig MR 200 6136100 FastMig MR 300 6136200 FastMig MS 200 6136300 FastMig MS 300 6136400
Accessories
Return current cable 5 m, 50 mm² 6184511 Return current cable 5 m, 70 mm² 6184711 Cable for MMA welding 5 m, 50 mm² 6184501 Cable for MMA welding 5 m, 70 mm² 6184701 R10 6185409 AS KIT 6264263 Remote controlled interconnecting cable 10 m 6185481 Cooling unit FastCool 10 6068100 Transport unit PM 500 6185291 Gun holder GH 30 6256030
EN
© Kemppi Oy / 1515
11
EN
9. TECHNICAL DATA
FastMig™ M 420MV
Connection voltage 3~, 50/60 Hz 220 V -10 %...230 V +10 % 380 V -10 %...440 V +10 % Rated power 60% ED 21 kVA 22 kVA
Connection cable H07RN-F 4G6 (5 m) 4G6 (5 m) Fuse (delayed) 50 A 35 A Output 40 °C 60 % ED 420 A 420 A
Welding current and voltage range MMA 15 A/20 V...420 A/48 V 15 A/20 V...420 A/44 V
Max. welding voltage 48 V 44 V Open circuit voltage MMA U0 = 48...53 V
Idle power 25 W 25 W Eciency at max. current 87 % 87 % Power factor at max. current 0.85 0.82 Operating temperature range -20...+40 ºC -20...+40 ºC Storage temperature range -40...+60 ºC -40...+60 ºC Degree of protection IP23S IP23S EMC class A A Minimun short circuit power Ssc of
supply network* External dimensions L x W x H 590 x 230 x 580 mm 590 x 230 x 580 mm Weight 49 kg 49 kg Voltage supply for auxiliary devices 50 V DC 50 V DC X14, X15 fuse 6.3 A delayed fuse 6.3 A delayed Operating voltage
(for cooling unit)
* See paragraph 2.2.
230 V range 400 V range
100% ED 18 kVA 19 kVA
100 % ED 380 A 380 A
MIG 20 A/12 V...420 A/48 V 20 A/12 V...420 A/44 V
U0 = 48...53 V
Uav = 50 V
MIG/MAG U0 = 60...65 V U0 = 53...58 V
N/A 5.6 MVA
380 V -10 %...440 V +10 % 380 V -10 %...440 V +10 %
Uav = 50 V
12
FastMig M 420MV
KEMPPI OY
Kempinkatu 1 PL 13 FIN-15801 LAHTI FINLAND Tel +358 3 899 11 Telefax +358 3 899 428 export@kemppi.com www.kemppi.com
Kotimaan myynti:
Tel +358 3 899 11 Telefax +358 3 734 8398 myynti.@kemppi.com
KEMPPI SVERIGE AB
Box 717 S-194 27 UPPLANDS VÄSBY SVERIGE Tel +46 8 590 783 00 Telefax +46 8 590 823 94 sales.se@kemppi.com
KEMPPI NORGE A/S
Postboks 2151, Postterminalen N-3103 TØNSBERG NORGE Tel +47 33 346000 Telefax +47 33 346010 sales.no@kemppi.com
KEMPPI DANMARK A/S
Literbuen 11 DK-2740 SKOVLUNDE DANMARK Tel +45 4494 1677 Telefax +45 4494 1536 sales.dk@kemppi.com
KEMPPI BENELUX B.V.
NL-4801 EA BREDA NEDERLAND Tel +31 765717750 Telefax +31 765716345 sales.nl@kemppi.com
KEMPPI (UK) LTD
Martti Kemppi Building Fraser Road Priory Business Park BEDFORD, MK44 3WH UNITED KINGDOM Tel +44 (0)845 6444201
Telefax +44 (0)845 6444202 sales.uk@kemppi.com
KEMPPI FRANCE S.A.S.
65 Avenue de la Couronne des Prés 78681 EPONE CEDEX FRANCE Tel +33 1 30 90 04 40 Telefax +33 1 30 90 04 45 sales.fr@kemppi.com
KEMPPI GMBH
Perchstetten 10 D-35428 LANGGÖNS DEUTSCHLAND Tel +49 6 403 7792 0 Telefax +49 6 403 779 79 74 sales.de@kemppi.com
KEMPPI SPÓŁKA Z O.O.
Ul. Borzymowska 32 03-565 WARSZAWA POLAND Tel +48 22 7816162 Telefax +48 22 7816505 info.pl@kemppi.com
KEMPPI AUSTRALIA PTY LTD
13 Cullen Place P.O. Box 5256, Greystanes NSW 2145 SMITHFIELD NSW 2164 AUSTRALIA Tel. +61 2 9605 9500 Telefax +61 2 9605 5999 info.au@kemppi.com
OOO KEMPPI
Polkovaya str. 1, Building 6 127018 MOSCOW RUSSIA Tel +7 495 240 84 03 Telefax +7 495 240 84 07 info.ru@kemppi.com
ООО КЕМППИ
ул. Полковая 1, строение 6 127018 Москва Tel +7 495 240 84 03 Telefax +7 495 240 84 07 info.ru@kemppi.com
KEMPPI, TRADING (BEIJING) COMPANY LTD
Unit 105, 1/F, Building #1, No. 26 Xihuan South Rd., Beijing Economic-Technological Development Area (BDA), 100176 BEIJING CHINA Tel +86-10-6787 6064 +86-10-6787 1282 Telefax +86-10-6787 5259 sales.cn@kemppi.com
肯倍贸易(北京)有限公司
中国北京经济技术开发区 西环南路261号楼1105室(100176) 电话: +86-10-6787 6064/1282 传真: +86-10-6787 5259
sales.cn@kemppi.com
KEMPPI INDIA PVT LTD
LAKSHMI TOWERS New No. 2/770, First Main Road, Kazura Garden, Neelankarai, CHENNAI - 600 041 TAMIL NADU Tel +91-44-4567 1200 Telefax +91-44-4567 1234 sales.india@kemppi.com
KEMPPI WELDING SOLUTIONS SDN BHD
No 12A, Jalan TP5A, Taman Perindustrian UEP, 47600 Subang Jaya, SELANGOR, MALAYSIA Tel +60 3 80207035 Telefax +60 3 80207835 sales.malaysia@kemppi.com
1905340
1515
www.kemppi.com
Loading...