Keating Of Chicago NSTANT RECOVERY AA2000, NSTANT RECOVERY BB2000, NSTANT RECOVERY TS2000 User Manual

SERIES 2000 FRYER MANUAL
INSTANT RECOVERY
®
GAS FRYER
READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE
Record the Model No. and Serial of this Instant Recovery® Gas Fryer in the space provided below.
Serial No. __________________________ Model No. __________________________
Keep these numbers for future reference
IMPORTANT: Keep a copy of your bill of sale. The date on the bill establishes the warranty period should ser­vice be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating com­mercial fryers are intended for other than household use.
CONTENTS:
Gas Fryer 2000 05/12
Important Safety Instructions . . . . . . . . . . . . . . .i
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . .1
INSTALLATION
Damage During Shipment . . . . . . . . . . . . . . . . .1
FIRST STEPS
Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
National Code Requirement . . . . . . . . . . . . . . .1
Gas Connectors & Pipe Size . . . . . . . . . . . . . .2
Flexible Gas Connection & Quick Disconnect
Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Restraining Devices . . . . . . . . . . . . . . . . . . . . .2
Electrical Connection . . . . . . . . . . . . . . . . . . . .2
Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PLACING YOUR KEATING FRYER IN OPERA­TION
Filling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5
Cooking . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Oil Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . .6
Draining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning and Boil-Out . . . . . . . . . . . . . . . . . .6-8
OPERATOR SELF HELP CHECK LIST 8
PREVENTATIVE MAINTENANCE
Preventive Maintenance Chart . . . . . . . . . . . . .9
Hi-Limit Check Bi-Monthly . . . . . . . . . . . . . . . . .9
Thermostat Calibration . . . . . . . . . . . . . . . . . . .9
Thermostat Bulb Positioning . . . . . . . . . . . . . . .9
Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
WARRANTY REPAIRS
Ordering Parts . . . . . . . . . . . . . . . . . . . . . . . . .11
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . .11-15
Wiring Diagrams . . . . . . . . . . . . . . . . . . . .15-18
1-800-KEATING
www.keatingofchicago.com
This Owner’s Guide provides specific operating instructions for your model. Use the Instant Recovery® Fryer only as instructed in this Service Guide.
Versión en español
Si desea obtener usa copia en español de estes Manual del Usario, sirvase escribir la dirección que se incluye a continuadión.
i
Improper installation,
adjustment, alteration,
service or maintenance
can cause property
damage, injury or death.
Read the installation,
operating and maintenance
instructions thoroughly
before installing or
servicing this equipment.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
*As continuous product improvement occurs, specifications may be changed without notice.
Purchaser should post in a prominent location instructions to
be followed in the event the user smells gas. This information
shall be obtained by consulting the local gas supplier.
THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA) AND THE FOOD SER­VICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION (FDA).
WARNING
IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUB­STANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CAN­CER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
WARNING
PROPANE GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAU­TIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR. IF THERE IS ANY DOUBT, YOU SHOULD CALL YOUR LOCAL PROPANE GAS SUPPLIER FOR ASSISTANCE.
INTRODUCTION
Instructions in this manual should be read thoroughly before attempting to operate this Keating Gas Fryer. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or autho­rized installation or service personnel.
Operating information for Keating equipment has been prepared for use by qualified and/or authorized per­sonnel.
Keating equipment is made in the U.S.A. and has American sizes of hardware. All metric conversions are approximate.
INSTALLATION INSTRUCTIONS
Proper installation will assure top performance. Alter­ation to your equipment will void the warranty. Before uncrating, check equipment carefully for damage.
IF EQUIPMENT ARRIVES DAMAGED
Keating does not assume responsibility for loss or damage incurred in transit.
IMPORTANT
This merchandise has been thoroughly inspected and carefully packed before leaving our plant. Responsibil­ity for its safe delivery was assumed by the carrier at the time of shipment. Claims for loss or damage to the contents should, therefore, be made upon the carrier, as follows:
CONCEALED LOSS OR DAMAGE
Concealed loss or damage means loss or damage which does not become apparent until the merchan­dise has been unpacked. The contents may be dam­aged in transit due to rough handling even though the carton may not show external damage. When the dam­age is discovered upon unpacking, make a written request for inspection by the carrier’s agent within fif­teen days of the delivery date. Then file a claim with the carrier since such damage is the carrier’s responsibili­ty. By following these instructions carefully, we guaran­tee our full support of your claims to protect you against loss from concealed damage.
VISIBLE LOSS OR DAMAGE
Any external evidence of loss or damage must be noted on the freight bill or express receipt, and signed by the carrier’s agent. Failure to adequately describe such external evidence of loss or damage may result in the carrier refusing to honor a damage claim. The form required to file such a claim will be supplied by the car­rier.
DO NOT RETURN DAMAGED MERCHANDISE
TO KEATING. FILE YOUR CLAIM AS ABOVE.
FIRST STEPS
POSITIONING
Keep appliance area free and clear of any com­bustibles. Position the Keating Gas Fryer 6 inches (152mm) from any combustible material. A minimum of 24 inches (610mm) should be provided at the front of the Keating Gas Fryer for servicing and proper opera­tion. Air for combustion enters the fryer from the bottom of the cabinet and the bottom of the control panel.
DO NOT BLOCK BOTTOM OF KEATING INSTANT
RECOVERY® GAS FRYER CABINET. DO NOT
OBSTRUCT FLUE.
Your Keating Instant Recovery® Gas Fryer is designed to be serviced from the front.
MINIMUM CLEARANCE
MINIMUM CLEARANCE
SUITABLE FOR COMBUSTIBLE FLOORS VENTI-
LATION
The Keating Gas Fryer must be installed in an area providing adequate air supply and ventilation. Do not obstruct the flow of combustion and ventilation air. Proper ventilation is one of the important considera­tions for efficient operation of the Keating Gas Fryer. It should be installed so that the products of combustion are removed efficiently without producing drafts that will interfere with proper burner operation. The intake for the exhaust fan should not be placed close to the flue of the Keating Gas Fryer to insure proper air flow necessary for combustion. The area around the front and bottom of the Keating Gas Fryer must be kept clear and unobstructed. In the U.S.A. the ventilation systems must conform to the ANSI/NFPA96 latest edi­tion. “A minimum of 18" (457mm) should be maintained between the flue outlet and the lower edge of the grease filters.” Must be installed at least 16" away from any open flame. It is the responsibility of the owner and the local installer to comply with national and local codes.
NATIONAL CODE REQUIREMENT
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas code, ANSI Z223.1 or the Natural gas Installation Code, CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2. Flexible connectors must comply to ANSI Z221.69/CAN/CGA1.16. Keating equipment is designed and manufactured to operate
Clearances
Combustible Noncombustible
Construction Construction
Back 6" 0"
Right Side 6" 0"
Left Side 6" 0"
1
2
only on the type of gas specified by the user and indi­cated on the serial plate located inside the door. The gas may be natural, propane or manufactured. The type of gas cannot be converted to another gas fuel by turning or engaging a switch.
GAS CONNECTIONS AND PIPE SIZE
A single Keating Gas Fryer requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. Multiple fryers with a common manifold will require a minimum of 1 1/4 inch I.D. gas supply line. The size of the gas supply pipe is very important. If the pipe is too small you will have low gas pressure at the Keating Gas Fryer manifold. Low gas pressure will cause slow recovery and/or delayed ignition. If you have a question about gas pipe size call your local gas company.
CCAAUUTTIIOONN
Before connecting new pipe to the Keating Gas Fryer the pipe must be blown out to remove all foreign parti­cles. These particles in the controls or burners may cause improper or dangerous operating conditions.
CCAAUUTTIIOONN
Pipe joint compounds that are used on threaded joints of appliance piping shall be resistant to the action of liq­uefied petroleum gases (Loctite PST 56765). When using pipe joint compound do not apply to the first two threads. Use only very small amount and only on male threads. This will prevent clogging of burner orifices and the gas valve. Never use compound on female threads as it might be pushed into the gas valve.
Have your installer check for gas leaks using a soap and water solution before operating. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
1) The Keating Gas Fryer and its individual shut off valves must be disconnected from the gas supply pip­ing system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45kPa) (13.84 in WC) High pressure can damage the gas valve caus­ing a hazardous condition.
2.) The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply pip­ing system at test pressures equal to or less than 1/2 psi (3.45 kPa).
NOTE: Line pressure must be kept below 10” (Nat), 13” (LP) to avoid damage to the gas valve.
The required gas pressure for proper operation of each fryer is 4" water col­umn for natural gas and 10" water col­umn for propane gas at the burner manifold.
If more than one gas unit is on the same supply line, you may require a larger line. Consult your local gas company to assure adequate volume and pressure. Refer to serial plate for proper gas requirement for your particular model.
FLEXIBLE GAS CONNECTORS AND QUICK DIS-
CONNECT DEVICES
For an appliance equipped with casters:
The installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or the Standard for Con­nectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 or the Standard for Quick Dis­connect Devices for Use with Gas Fuel, CAN1-6.9.
RESTRAINING DEVICES
1.) Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associ­ated piping to limit the appliance movement.
Fryer must also be restrained to pre­vent tipping when installed so that hot liquid splashing is avoided.
2.) The restraint means must be
attached to the rear of the Keating Gas Fryer within 2" of the center line width and approximately 1-5/8" from the bottom of the cabinet back to allow the restraining bolt to be anchored to the cabinet back between the cabinet bottom and inner liner.
IF DISCONNECTION OF THE RESTRAINT IS NEC­ESSARY, IT MUST BE RECONNECTED WHEN THE KEATING GAS FRYER IS RETURNED TO ITS ORIG­INALLY INSTALLED POSITION.
INSTALLATION
The installer is responsible for attaching the tipping restraint.
ELECTRICAL CONNECTION
The Keating Gas Fryer, when installed, must be elec­trically grounded in accordance with local codes, or in the absence of local codes, the National Electrical Code, ANSI/NFPA No. 70. or the Canadian Electrical Code, CSAC-22.2 as applicable. A wiring diagram is located on the last page. In the U.S.A. and Canada, the
electrical supply must be 120 VAC, 60 Hz.
WWAARRNNIINNGG
This appliance is equipped with a three-prong 120 Volt NEMA 5-15 (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded and polarized three-prong
3
receptacle. Do not cut or remove the grounding prong from this plug. (Model AA has no electric connection).
LEVELING
The Keating Gas Fryer will operate at its highest effi­ciency when properly leveled. Place a level on the fryer from side to side. For fryer on legs, the bottom foot of the leg is adjustable. Turn counterclockwise to decrease height, or clockwise to increase height until level. For fryers with casters, the casters are adjustable by loosening the jam nut and turn the caster in or out. When the desired level is reached, tighten the jam nut. Adjustments of more than 3/4" are not recommended on any caster. The same procedure should be followed to level the fryer from front to back.
PLACING KEATING GAS
FRYER IN OPERATION
Never leave your fryer operating unattended. (When all previous instructions have been completed). Check the serial plate on the panel (inside cabinet) to
determine if the burner is set up for the proper type gas before connecting the quick-disconnect or piping from the building gas supply pipe.
a. Maximum incoming gas pressure
NATURAL GAS – 7 inches W.C. with burners on
LP GAS – 11 inches W.C. with burners on If a popping noise is heard from the fryer during the cooking cycle, the following checks must be made in this order:
b. Fryer manifold gas pressure
NATURAL GAS – 4 inches W.C. with burners on
LP – 10 inches W.C. with burners on
ALWAYS disconnect fuel source and power
supply before servicing.
NEVER move a fryer when full of oil.
NEVER introduce objects or liquids into fryer,
while operational, which are not designed or
made for cooking.
THIS FRYER MAY NOT BE ALTERED, MODIFIED OR CHANGED IN ANY WAY.
FILLING
NOTE: Before filling the fryer make certain the fryer
vessel is sanitized, dry and the drain valve is completely closed.
NOTE: We recommend that solid shortening not be used in a Keating Gas Fryer if it is not equipped with a melt cycle. If solid shortening is used, it should be melt­ed prior to filling the fryer vessel. Damage done by melting solid shortening in the fryer vessel will void the warranty.
CCAAUUTTIIOONN
Oil expands when heated. The “Fill Level” line has been provided to ensure optimum cooking while ensur­ing the safety of the operator. Do not overfill the fryer vessel.
Fill Level Line
Fill the fryer vessel with oil or MELTED solid shortening up to the “Fill Level” line.
CCAAUUTTIIOONN
BE SURE THE HEAT TRANSFER TUBES ARE COM­PLETELY COVERED WITH OIL BEFORE SWITCH­ING THE FRYER ON. IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES, SEVERE DAM­AGE TO FRYER AND INJURY TO OPERATOR MAY RESULT.
LIGHTING INSTRUCTIONS
(See lighting instructions plate attached to the inner door of Keating Gas Fryer.) Model AA does not require an electrical connection.
Make sure that the Keating Gas Fryer is plugged in. If not your fryer will not operate. Make sure that the main gas valve on the gas supply line to the Keating Gas Fryer is in the “ON” position.
4
AA CONTROL PANEL
BB CONTROL PANEL
34×24 BB CONTROL PANEL
34×24 TS CONTROL PANEL
TS CPU CONTROL PANEL
AIR IN THE GAS SUPPLY LINE MAY REQUIRE A LONGER THAN NORMAL PERIOD OF TIME TO LIGHT YOUR FRYER DURING INITIAL INSTALLA­TION OR AFTER OVERNIGHT SHUTDOWN
NOTE: Unless you have an AA model your fryer cannot be operated during a power failure.
AA MODELS OPERATING INSTRUCTIONS
ST
ART-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT FIRST FILLING FRYER POT.
STEP 1. Set thermostat to the "OFF" position. STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. STEP 3. Turn gas valve knob to "PILOT" position. STEP 4. Light constant pilot located on left side of
pilot runner tube. STEP 5. Push and hold the gas valve knob for 30 sec-
onds and release. STEP 6. With the pilot still on, turn gas valve knob to
the "ON" position. STEP 7. Set thermostat to desired temperature, turn
"MAIN POWER" switch to the "ON" position.
The burners will come on.
HIGH LIMIT TEST PROCEDURE (All Models): DO BI-MONTHLY
STEP 1. Place a suitable thermometer in the oil on
the front left corner of the fryer 2" from the
top to check temperature. STEP 2. Set thermostat to 375°F after burners go off.
Push and hold the "HIGH LIMIT TEST"
switch. The burners will come on. STEP 3. When 425°F is reached the burners go off.
Now it is ok to release test switch. STEP 4. If the high limit thermostat does not shut
down the burners between 425°-450°F as
read on the thermometer, the high limit must
be replaced immediately. STEP 5. To re-start the fryer it must be cooled down to
cooking temperature and the red reset but-
ton on the high limit thermostat pushed.
Return to STEP 3 in the start-up procedure.
SHUTDOWN PROCEDURE
STEP 1. Set thermostat to the "OFF" position. STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. STEP 3. Turn gas valve knob to the "OFF" position. STEP 4. Turn gas supply valve to the "OFF" position. STEP 5. Check to make sure all burners and pilot are
out.
BB MODELS OPERATING INSTRUCTIONS
ST
ART-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT FIRST FILLING FRY POT.
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE" posi-
tion and thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "ON"
position.
STEP 3. Hold the "PUSH TO LIGHT" switch in until
the amber "PILOT ON" light comes on. STEP 4. Set thermostat to desired temperature. STEP 5. Set "MELT-IDLE-FRY" switch to "FRY." The
burners will come on. Select "MELT" with
solid shortening until liquid shortening is 1"
from full, then switch to the "FRY" position.
HIGH LIMIT TEST PROCEDURE: DO BI-MONTHL
Y
STEP 1. Place a suitable thermometer in the oil on
the front left corner of the fryer 2" from the
top to check temperature. STEP 2. Set thermostat to 375°F after burners go off.
Push and hold the "HIGH LIMIT TEST"
switch. The burners will come on. STEP 3. When 425°F is reached the burners go off.
Release test switch. STEP 4. If the high limit thermostat does not shut
down the burners between 425°-450°F as
read on the thermometer, the High Limit
must be replaced immediately. STEP 5. To re-start the fryer it must be cooled down to
cooking temperature and the red reset but-
ton on the high limit thermostat pushed.
Return to STEP 3 in the start-up procedure.
SHUTDOWN PROCEDURE
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE" posi-
tion and thermostat to the "OFF" position. STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off. STEP 3. Check to make sure all burners and pilot are
out.
TS MODELS OPERATING INSTRUCTIONS
ST
ART-UP PROCEDURE
WARNING: DO NOT START FRYER WITHOUT FIRST FILLING FRYER POT.
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE" posi-
tion and thermostat to the "OFF" position. STEP 2. Turn "MAIN POWER" switch to "ON" posi-
tion. Its green light and the timers will come
on. STEP 3. Light constant pilot located on left side of
pilot runner tube. STEP 4. Hold the "PUSH TO LIGHT" switch for 30
seconds. The pilot runner tube will light. STEP 5. Set thermostat to desired temperature. STEP 6. Set "MELT-IDLE-FRY" switch to "FRY" with
oil in the fry pot. The burners will come on.
Select "MELT" with solid shortening until liquid shortening is 1" from full mark then switch to the "FRY" position. Burners will come on.
HIGH LIMIT TEST PROCEDURE: DO BI-MONTHL
Y
STEP 1. Place a suitable thermometer in the oil on
the front left corner of the fryer 2" from the top to check temperature.
STEP 2. Set thermostat to 375°F after burners go off.
Push and hold the "HIGH LIMIT TEST" switch. The burners will come on.
STEP 3. When 425°F is reached the burners go off
and the "OVER MAX TEMP" red light will come on. Release test switch.
STEP 4. If the high limit thermostat does not shut
down the burners between 425°-450°F as read on the thermometer, the high limit must be replaced.
STEP 5. To re-start the fryer it must be cooled down to
cooking temperature and the red reset but­ton on the high limit thermostat pushed. The red light will go off. Return to STEP 3 in the start-up procedure.
SHUTDOWN PROCEDURE
STEP 1. Set "MELT-IDLE-FRY" switch to "IDLE" posi-
tion and thermostat to the "OFF" position.
STEP 2. Turn "MAIN POWER" switch to the "OFF"
position. Its green light will go off.
STEP 3. Check to make sure all burners and pilot are
out.
COOKING
Keating's Instant Recovery® Gas Fryer is designed to provide maximum production efficiency and deliver high quality food products. Low temperature cooking, highly polished stainless steel and a true COLD ZONE mean extended oil life. Follow all cooking procedures for your model.
Cold Zone
5
6
CCAAUUTTIIOONN
OPERATION OF THIS FRYER SHOULD BE LIMITED TO PERSONNEL WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATING PROCEDURES.
Set thermostat to the desired frying temperature.
CCAAUUTTIIOONN
CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL.
If your fryer has timers, push “Start-Stop” button of electronic timer(s). For fryers with automatic basket lift, basket(s) will lower into fryer vessel.
When timer(s) sounds, carefully lift basket(s) out of hot oil. For fryers with automatic basket lift, a buzzer will sound and the basket(s) will rise automatically. Allow oil to drain before removing.
CCAAUUTTIIOONN
DO NOT LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT
USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER. NEVER OVERFILL FRY BASKETS. DO NOT BANG BASKETS ON BASKET HANGERS OR ON FRYER VESSEL.
Place basket(s) on basket hanger rods on splashback of fryer and allow to drain.
SHUTDOWN INSTRUCTIONS
Always turn the fryer off each night.
1. See Shutdown procedure.
OIL BREAKDOWN
As part of a “Preventive Maintenance Program”, the oil in your fryer needs to be filtered regularly. The initial investment in the frying system is less than the total overall costs of oil during the life of the fryer, and with regular filtering, you can realize substantial savings in oil costs, as well as, maintenance charges. We have listed some of the conditions which are catalysts in the breakdown of oil:
1. Contact with Oxygen
2. Carbonization of Crumbs and Food Particles
3. Non-Stainless Steel Surfaces
4. Keep Salt and Seasonings Away From Oil
5. Prolonged High Temperatures
DRAINING
Operator in safety gear
CCAAUUTTIIOONN
ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING. THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED TO ENSURE THE SAFETY OF THE OPERATOR.
1. Operator should be outfitted with proper attire including:
–Oil and heat resistant gloves –Oil and heat resistant apron –Safety goggles –Oil and heat resistant footwear
2. Turn off the fryer and open the door.
3. Put suitable container under drain valve.
4. Drain oil from fryer by slowly turning handle. The drain will be completely open after 1/4 turn.
5. After fryer drains close the drain valve.
6. Filtering may be done at this step.
NOTE: Fryers with a central filter will drain differently.
CLEANING AND BOIL-OUT FOR A
SINGLE FRYER
When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition.
1. Operator should be outfitted with proper attire including:
–Oil and heat resistant gloves –Oil and heat resistant apron –Safety goggles –Oil and heat resistant footwear
Turn the fryer off. Remove baskets and screen.
2. Drain oil from fryer, see draining.
CCAAUUTTIIOONN
A KEATING FRYER OR FILTER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. WHEN DISCARDING OIL, A COVERED RECEPTACLE APPROVED FOR USE WITH HOT OIL SHOULD BE USED. USE OF A NON­APPROVED RECEPTACLE OR METHOD OF DRAINING THE OIL COULD JEOPARDIZE THE SAFETY OF THE OPERATOR.
3. Remove oil container to a secure area to prevent accidental spillage.
4. Fill fryer vessel to "Fill Level" line with water.
5. Set thermostat and turn fryer on to bring water to a gentle boil. Once boil has been reached, turn fryer off.
CCAAUUTTIIOONN
UNDER NO CIRCUMSTANCES SHOULD THE FRYER AND FILTER BE LEFT UNATTENDED DUR­ING BOIL-OUT. TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PRE­VENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEATING TRANSFER TUBES.
6. Dissolve 2/3 cup of Keating Sea Powder for every five gallons of water and let soak for 1/2 hour. If there is a large build-up of carbonized grease, allow for fryer to soak overnight.
7. While soaking, a natural fiber brush may be used to scrub the tubes and inside walls of fryer. Drain the water and Sea Powder into a dry suitable receptacle and remove from cooking area. Sprinkle Keating Klenzer liberally on tubes and sides of fryer vessel. A non-abrasive scouring pad amy be used to remove the now softened carbonized grease. Thoroughly rinse fryer vessel with potable water to remove all Klenzer. Prior to refilling with oil, wipe the inside of the fryer vessel making sure all water and Klenzer have been removed.
NOTE: Do not pump water through the filter system.
DO NOT DAMAGE OR REPOSITION THERMOSTAT PROBE AS THIS MAY AFFECT THE ACCURACY OF THE FRYER.
CCAAUUTTIIOONN
DO NOT MIX WATER AND HOT OIL
8. Close the drain valve.
9. Check thermostat bulb positioning.
10. Refill the fryer with new or filtered oil.
TO AVOID DAMAGING THE FRYER, DO NOT POWER WASH, SPRAY OR HOSE IT DOWN WHILE CLEANING IT.
CLEANING AND BOIL-OUT FOR A FRYER WITH
ATTACHED FILTER SYSTEM
When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition.
CCAAUUTTIIOONN
A KEATING FRYER OR FILTER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. WHEN DIS­CARDING OIL, A COVERED RECEPTACLE APPROVED FOR USE WITH HOT OIL SHOULD BE USED. USE OF A NON-APPROVED RECEPTACLE OR METHOD OF DRAINING THE OIL COULD JEOP­ARDIZE THE SAFETY OF THE OPERATOR.
1. Operator should be outfitted with proper attire including:
–Oil and heat resistant gloves –Oil and heat resistant apron –Safety goggles –Oil and heat resistant footwear
2. Turn the fryer off.
A cleaning hose and wand have been provided for discarding oil.
3. Attach cleaning hose to quick disconnect located on the bottom right side of your filter.
4. Remove baskets and screen. Drain fryer into the central filter drawer.
7
SAFE & EASY FILTER
(SIDE VIEW)
Connect hose here to discard oil
8
5. Open the discard valve located near the quick dis­connect in the filter cabinet.
6. The hose may now be used to pump the oil into the shortening handling system and discarded proper­ly.
7. Remove oil container to a secure area to prevent accidental spillage.
8. Fill fryer vessel to “Fill Level” line with water.
9. Set thermostat and turn fryer on to bring water to a gentle boil. Once boil has been reached, turn fryer off.
WWAARRNNIINNGG
UNDER NO CIRCUMSTANCES SHOULD THE FRYER AND FILTER BE LEFT UNATTENDED DUR­ING BOIL-OUT. TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PRE­VENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEATING TRANSFER TUBES.
10. Dissolve 2/3 cup of Keating Sea Powder for every five gallons of water and let soak for 1/2 hour. If there is a large build-up of carbonized grease, allow fryer to soak overnight.
11. While soaking, a natural fiber brush may be used to scrub the tubes and inside walls of fryer. Pump the water and Sea Powder into a dry suitable receptacle and remove from cooking area. Sprinkle Keating Klenzer liberally on tubes and sides of fryer vessel. A non-abrasive scouring pad may be used to remove the now softened carbonized grease. Thoroughly rinse fryer vessel with potable water to remove all Klenzer. Prior to refilling with oil, wipe the inside of the fryer vessel making sure all water and Klenzer have been removed.
DO NOT DAMAGE OR REPOSITION THERMOSTAT PROBE AS THIS MAY AFFECT THE ACCURACY OF THE FRYER.
CCAAUUTTIIOONN
DO NOT MIX WATER AND HOT OIL
12. Close the drain valve and disconnect the cleaning hose.
Quick disconnect will remain hot for approximately 15 minutes.
13. Check thermostat bulb positioning (should be 1 paper thickness away from heat tube).
14. Refill the fryer with new or filtered oil.
Wait until filter drawer is cool before cleaning, approximately 15 minutes.
15. Remove filter drawer, drain, clean and dry.
16. Prepare filter drawer and return to filter cabinet.
TO AVOID DAMAGING THE FRYER, DO NOT POWER WASH, SPRAY OR HOSE IT DOWN WHILE CLEANING IT.
17. Pump must be primed with oil after boil-out with water.
Failure to lubricate pump may cause severe dam­age to Filter System.
OPERATOR SELF HELP
Before calling for service, review this list. It may save you both time and expense. This list includes com­mon occurrences that are not the result of defective workmanship or materials in this appliance.
NOTE: For a fryer with a Central, Zero-Space™ Filter, or Safe & Easy Filter always check the rear drain oper­ating handle before attempting to use the fryer. A safe­ty switch prevents the fryer from operating if the handle is not pushed in completely and latched. (See figure 3-
2)
Figure 3-2
Rear Drain Operating Handle
OCCURRENCE SOLUTION
Fryer does not Check power cord, unit operate: plugged in?
Thermostat is in the
off position.
Check gas supply.
See figure below.
Reset high limit.
PREVENTIVE MAINTENANCE
Preventive maintenance should be done in daily, week­ly, monthly and yearly intervals as necessary. Following preventive maintenance procedures will help keep your fryer working efficiently. Proper care and servicing will lead to years of quality performance.
PREVENTIVE MAINTENANCE CHART
*High production facilities should be checked more often. Contact your local service company to perform maintenance and repairs.
HI-LIMIT CHECK BI-MONTHLY
The manual Hi-Limit test button can be used to test the Hi-Limit Control by pushing and holding the button in until the fryer reaches the Hi-Limit temperature (425°F). Place an accurate thermometer in the oil. If the Hi-Limit Control doesn’t shut off the fryer between 425°F and 450°F, have it replaced.
THERMOSTAT CALIBRATION
You will need:
One screwdriver with 1/8" wide flat blade
One accurate fryer thermometer
1. Set thermostat to desired frying temperature.
2. Allow fryer to cycle three times.
3. Place an accurate thermometer in the oil.
Thermostat calibration
NOTE: Locate thermometer in same position for
every calibration. Left front corner of fryer vessel at the High Limit Bulb is recommended.
4. If temperature of fryer is found to be more or less than 15°F off, remove the thermostat knob. There are (4) screws holding the dial plate in place. Loosen the screws and reset the dial plate to match the thermometer reading.
BEFORE REPLACING, TEST THERMOSTATS
These operational problems can easily be correct­ed by thermostat bulb positioning.
Keating’s patented thermostat application is accu­rate within 2°F of the dial setting between 250°F – 350°F. This accuracy is attained only if the thermo­stat bulb is placed properly against the heat trans­fer tube. To quickly and accurately test for proper bulb placement, a single thickness of writing paper should be pulled through between the tube and the bulb with medium resistance.*
1. *For gas fryers 14":
The end of thermostat bulb should touch the burn-
er tube.
2. For gas fryers 10x11, 18 & up:
If the bulb is too loose, the paper will slip through
with little or no resistance. A fryer with a thermostat bulb that is too loose will overshoot.
Overshoot: The thermostat takes a long time to cycle and then misses its preset temperature by 20°F - 40°F yielding a poor quality product.
If the bulb is too tight, the paper will either not pull
through or it will tear. A fryer with a thermostat bulb that is too tight will short cycle.
Short Cycle: The thermostat will cycle rapidly while the fryer is in the idle mode; the temperature will be erratic.
Thermostat Bulb Positioning 10x11, 18 & up Fryer Gas
TIME OPERATOR/OWNER FRAME
Daily* Check lights and controls.
Check that the oil is up to “Fill Level” Line.
Clean all baskets.
Drain, strain or filter oil.
Weekly* Drain and clean fryer.
Boil-out fryer.
BiMonthly Hi-Limit & Test procedures.
Monthly* Check calibration of the thermostat.
Yearly* QUALIFIED SERVICE
PERSONNEL ONLY
Check burner flame color and adjust air
shutters.
Remove and clean all orifices.
Check and replace radiants.
9
REQUIRED TEST EQUIPMENT:
Multimeter (for testing continuity)
CHECKING CONTINUITY WITH THE MULTIMETER
1. Rotate the thermostat shaft until an audible click is heard.
2. Rotate the thermostat shaft left and right ten times causing the switch to click on and off ten times, while using the Multimeter to verify continuity.
3. If the switch does not show continuity during all ten trials, replace the thermostat.
WARNING
Disassembling the thermostat will void the ther­mostat warranty.
1. Set compression ring onto capillary end of bulb finger tight, 1/2” from end of capillary.
2. Insert new thermostat bulb through control panel back.
3. Apply oil resistant flexible sealant onto compres­sion fitting thread before installing fitting into fryer vessel.
4. Position bent portion of bulb against far right heat transfer tube and install compression fitting snugly into fryer vessel.
5. Adjust bulb so at least 2” of bent portion of it is next to heat transfer tube and tighten compres­sion nut onto compression fitting for fryer 10x11, 18 & up. The end of thermostat bulb should touch the burner tube for 14" fryers.
6. Replace burners.
7. Replace control panel back.
8. Slide back fabric shield over capillary and care­fully coil capillary. Avoid crimping.
9. Reconnect wires to thermostat body.
10. Replace two screws which hold thermostat body to control panel.
11. Replace control panel.
12. Replace three retaining screws and washers which hold dial plate in place.
13. Replace thermostat knob.
14. Connect electric power source. Turn on gas and pilots.
15. Boil out fryer.
16. Refill fryer with oil to “fill level line”.
17. Start fryer, preheat and calibrate with thermometer.
“KEATING” ELECTRONIC TIMER
(PART # 023709)
HOW TO PROGRAM THE “KEATING”
ELECTRONIC TIMER
Make certain power to the timer has been OFF for at least 30 seconds. Then PRESS and hold down the UP arrow but­ton while turning the rocker power switch to the ON posi­tion.
Note: If power switch does not turn off timers, the unit must be unplugged (two people may be needed).
The timer will turn ON and the display will now be indicating
OR
The BEEPER will BEEP 4 times.
If STEP 1 was OK, proceed to STEP 2. If not, retry Step 1 making sure the power was OFF for at least 30 seconds or more.
– – –
– – –
10
STEP 2 PRESS all 3 buttons in sequence: left-center-right.
The BEEPER will BEEP when each button is pressed. If BEEPER does not BEEP, the timer is defective. STOP TESTING. Reset procedure is completed when 1:00 appears on the digital dis­play.
OPTIONAL TIMER
OPERATING INSTRUCTIONS
PART # 056921
DIGITAL TIMERS
The electronic timers, standard on TS & IFM models, provide a clearly visible and accurate display and are very easy to use.
PROGRAMMING
To program the timers, the unit must be in the idle mode. Press and hold the set button for approximately two sec­onds. The display will show “SEt”. Press the button for the channel to be programmed. The display will show the cur­rent setting for that channel. Use the up or down button to increment or decrement the setting. When the setting is correct, press and hold the set button again for approxi­mately two seconds. The display will show "StO" for approximately two seconds and the timer will return to normal operation. Repeat the process as necessary for the other timers.
OPERATING LOGIC
When the timer is powered up, the display will show the time setting for the channel that was operated last and the relay output contacts will be open. To start a cycle, press the desired channel button (1-3). The display will begin to countdown from the preset time setting and the relay out­put contacts will close. During the countdown the colon will flash at a one-second rate. When the countdown has reached "00:00" the relay output contacts will open, the display will flash, and the audible alarm will sound. To can­cel the audible alarm, press any button.
PAUSE FEATURE
To pause a cycle in progress, press any button. The relay output contacts will open, the display will flash, and the countdown will pause. To resume the countdown, press any button. The display will resume the normal countdown and the relay output contacts will close.
CANCELING A CYCLE
To cancel a cycle in progress press and hold any button for approximately two seconds. The relay output contacts will open and the display will show the time setting for the channel last used.
WARRANTY REPAIRS
Keating's warranty begins with the date of installation. In the event that your Fryer, under warranty, needs repairs other than routine cleaning, you are requested to contact KEATING OF CHICAGO, INC. (1-800-KEATING) before calling a local service compa­ny.
ORDERING PARTS
Parts may be ordered by part number by calling your local service company or Keating at 1-800-KEATING. You may also order on-line at Keating’s part store, www.keatingofchicago.com.
Refer to the Keating Gas Fryer Limited Warranty for warranty service information.
The model/serial plate is located on the inside of the front door. The serial and model numbers are neces­sary when ordering.
WARNING AND OPERATING PLATES
All warning and operating plates on the Keating Gas Fryer should be in place at all times.
PARTS LIST
CONTROL PANEL AA GAS
Corresponds with parts list on page 12
11
1:00
QTY. DESCRIPTION PART #
A 1 THERMOSTAT DIAL PLATE 375° 058037
B 1 THERMOSTAT KNOB, BLACK 060612
C 1 GAS FRYER THERMOSTAT
14” 14CM and AA 023145
10x11 18 and up 035553
D 1 SWITCH ROCKER WHITE
ON/OFF 035030
E 1 SWITCH ROCKER MOMENTARY 032297
F 1 HIGH LIMIT (RESETTABLE)
GAS 034357
CONTROL PANEL BB GAS
QTY.DESCRIPTION P/N
A 1 THERMOSTAT DIAL PLATE 375° 058037
B 1 THERMOSTAT KNOB, BLACK 060612
C 1 GAS FRYER THERMOSTAT
14” BB, TS, IFM, CPU 035574
10x11, 18” and up 035575
D 1 SWITCH MELT-IDLE-FRY 032829
E 1 HIGH LIMIT (RESETTABLE) 034357
F 1 FLAME SWITCH 037406
G 1 SWITCH ROCKER WHITE
MOMENTARY (PUSH TO LIGHT) 032297
H 1 INDICATING LIGHT AMBER 021254
J 1 SWITCH ROCKER WHITE
(LIGHT REPLACEMENT KIT) 058328
K 1 SWITCH ROCKER WHITE
MOMENTARY (HIGH LIMIT TEST) 032297
12
TS CONTROL PANEL
QTY. DESCRIPTION P/N
A 1 THERMOSTAT DIAL PLATE 375° 058037
B 1 THERMOSTAT KNOB, BLACK 060612
C 1 GAS FRYER THERMOSTAT
14” BB, TS, IFM, CPU 035574
10x11, 18” and up 035575
D 1 SWITCH ROCKER WHITE
(LIGHT REPLACEMENT KIT) 058328
E 2 DIGITAL TIMER 24V 056921
F 2 SWITCH ROCKER WHITE 032297
MOMENTARY (PUSH TO LIGHT, HIGH LIGHT TEST)
G 1 SWITCH MELT/IDLE/FRY 032829
H 1 INDICATING LIGHT GREEN 021255
I 1 INDICATING LIGHT RED 021209
J 1 HIGH LIMIT (RESETTABLE) 034357
K 1 FLAME SWITCH 037406
D
F
G
H
I F
B,C
A
E
J
K
CONTROL PANEL TS GAS
ELECTRICAL BOX ASSEMBLY GAS FRYER
(TS and BB ONLY)
QTY. DESCRIPTION P/N
A 1 TRANSFORMER 120V/240V TO 24V 032408 B 1 2 PIN CONNECTOR 032207
C 1 9 PIN CONNECTOR 028303
D 1 FAT MELT 24V 034272
POT ASSEMBLY 14AA GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 3 3 FIN RADIANT 000041
B 1 POT WELDMENT 14” GAS UNI-POT
Call 800-KEATING
C 3 BURNER 028048
D 1 DRAIN VALVE 1” 004553
1 REAR DRAIN VALVE (NOT SHOWN) 016341
E 1 RUNNER PILOT TUBE ASSEMBLY 019408
F 1 GAS VALVE NAT. 023625
LP. 023624
POT ASSEMBLY 14BB & 14TS GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 3 3 FIN RADIANT 000041
B 1 POT 14” GAS WELDMENT Call 800-KEATING
C 3 BURNER 028048
D 1 DRAIN VALVE 004553
1 REAR DRAIN VALVE (NOT SHOWN) 016341
E 1 RUNNER PILOT ASSEMBLY 018814
F 1 GAS VALVE NAT. (FRONT DRAIN TS) 037237
LP. (FRONT DRAIN TS) 037238
1 GAS VALVE NAT. (REAR DRAIN TS) 037241
LP. 037242
1 GAS VALVE NAT. (ALL BB MODELS) 037227
LP. 037228
POT ASSEMBLY 18AA GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 4 3 FIN RADIANT 000041
B 1 POT 18” GAS WELDMENT Call 800-KEATING
C 4 BURNER 028048
D 1 DRAIN VALVE 004554
1 DRAIN VALVE 2” FRONT 021256
1 REAR DRAIN VALVE (NOT SHOWN) 016342
E 1 RUNNER PILOT ASSEMBLY 000647
F 1 GAS VALVE NAT. 023625
LP. 023624
13
A
B
F
D
E
C
F
E
B
C
D
E
F
A
B
C
D
A
POT ASSEMBLY 18BB & 18TS GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 4 3 FIN RADIANT 000041
B 1 POT 18” GAS WELDMENT Call 800-KEATING
C 4 BURNER 028048
D 1 DRAIN VALVE 004554
1 DRAIN VALVE 2” FRONT 021256
1 REAR DRAIN VALVE (NOT SHOWN) 016342
E 1 RUNNER PILOT ASSEMBLY 004243
F 1 GAS VALVE NAT. (FRONT DRAIN TS) 037237
LP. (FRONT DRAIN TS) 037238
1 GAS VALVE NAT. (REAR DRAIN TS) 037241
LP. 037242
1 GAS VALVE NAT. (ALL BB MODELS) 037227
LP. 037228
POT ASSEMBLY 20AA GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 4 3 FIN RADIANT 000041
B 1 POT 20” GAS WELDMENT Call 800-KEATING
C 4 BURNER 028048
D 1 DRAIN VALVE 004554
1 DRAIN VALVE 2” FRONT 021256
1 REAR DRAIN VALVE (NOT SHOWN) 016342
E 1 RUNNER PILOT ASSEMBLY 000649
F 1 GAS VALVE NAT. 023625
LP. 023624
POT ASSEMBLY 20BB & 20TS GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 4 3 FIN RADIANT 000041
B 1 POT 20” GAS WELDMENT Call 800-KEATING
C 4 BURNER 028048
D 1 DRAIN VALVE 004554
1 DRAIN VALVE 2” FRONT 021256
1 REAR DRAIN VALVE (NOT SHOWN) 016342
E 1 RUNNER PILOT ASSEMBLY 004246
F 1 GAS VALVE NAT. (FRONT DRAIN TS) 037237
LP. (FRONT DRAIN TS) 037238
1 GAS VALVE NAT. (REAR DRAIN TS) 037241
LP. 037242
1 GAS VALVE NAT. (ALL BB MODELS) 037227
LP. 037228
POT ASSEMBLY 24BB & 24TS GAS
(Front Drain Shown)
QTY. DESCRIPTION P/N
A 5 3 FIN RADIANT 000041
B 1 POT 24” GAS WELDMENT Call 800-KEATING C 5 BURNER 028048 D 1 DRAIN VALVE 004554
1 DRAIN VALVE 2” FRONT 021256
1 REAR DRAIN VALVE (NOT SHOWN) 016342 E 1 RUNNER PILOT ASSEMBLY 004579 F 1 GAS VALVE NAT. (FRONT DRAIN TS) 037237
LP. (FRONT DRAIN TS) 037238
1 GAS VALVE NAT. (REAR DRAIN TS) 037241
LP. 037242
1 GAS VALVE NAT. (ALL BB MODELS) 037227
LP. 037228
14
A
B
C
D
E
F
A
B
C
E
F
D
A
B
C
D
E
F
A
B
C
D
E
F
15
AA2000 ELECTRICAL ASSEMBLY
BB2000 ELECTRICAL ASSEMBLY
16
Electrical Assembly not shown to scale
TS2000 ELECTRICAL ASSEMBLY
Electrical Assembly not shown to scale
BB ELECTRICAL ASSEMBLY WITH SE FILTER
17
TS ELECTRICAL ASSEMBLY WITH SE FILTER
BASKET LIFT ELECTRICAL ASSEMBLY (ALL FRYERS)
18
PROBLEM PROBABLE CAUSE SOLUTION
Fryer overshoots a. Thermostat bulb improperly a. Adjust bulb position. See page 9 – temperature setting. placed. Thermostat Bulb Positioning.
b. Thermostat out of calibration. b. Calibrate thermostat. See page 9 –
Calibration.
Oil in fryer vessel smokes. a. Oil has begun to breakdown. a. Replace oil.
b. High carbon content in oil. b. Filter oil completely, replace if
necessary.
c. Dirty fryer vessel. c Boil-out fryer.
d. Inferior grade of oil. d. Check with supplier for the grade of oil
needed for your cooking applications.
e. Fryer is overheating. e. Check calibration of thermostat (See
page 9) and replace if necessary.
Fryer vessel boiling over. a. Over-filling fryer with oil. a. Fill fryer up to “Fill Level” Line as oil
will expand when heated.
b. Product overloaded in fryer b. Follow recommended cooking
vessel. production figures in determining
proper size of loads.
c. Oil breakdown causing foaming. c. Replace oil.
d. Water in the cold zone. d. Stir oil repeatedly with a paddle until
water boils off. Filter oil. If necessary, allow oil to cool. Drain about one quart of it to remove remaining water.
Basket lift mechanism a. Connections are loose or a. Make sure connections are tight. will not operate. electronic timer is faulty. Replace timer if faulty.
b. Motor limit switch is faulty. b. Replace limit switch or straighten arm.
c. Lift motor is faulty. c. Replace motor. Specify left or right side
motor when ordering.
d. Basket lift relay is faulty. d. Replace relay. e. Actuator is defective e. Replace Actuator
Basket lift motor runs, but a. Cam is slipping on motor shaft. a. Tighten cam onto motor shaft. basket does not move.
Runner bar will not light
Burners with not light
a. (For AA units) - gas valve knob
in incorrect position.
b. (BB and TS units) Hi Limit
tripped.
a. (For AA units) gas valve knob in
incorrect position.
b. (BB and TS units) switch not
set to fry.
a. Rotate gas valve knob to PILOT
position. Depress and hold for 30 seconds.
b. Reset High Limit
a. Rotate gas valve knob to ON. Turn
power switch ON. Set thermostat to desired temperature
b. Set MELT/IDLE/FRY switch to FRY.
Set thermostat to desired temperature.
KEATING LIMITED WARRANTY CARD
PLEASE COMPLETE AND MAIL AT ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED.
WARRANTY CARD IS ALSO AVAILABLE TO COMPLETE ON LINE AT YOUR CONVENIENCE.
COMPANY: __________________________________________________________________________________________________________________
ADDRESS: __________________________________________________________________________________________________________________
CITY: ______________________________________________________________________________ STATE: ________________ ZIP: ____________
DEALER: ____________________________________________________________________________________________________________________
DATE OF PURCHASE: ________________________________________________________________ INVOICE NUMBER: ____________________
SERIAL NUMBER: ________________________________________  FRYER FILTER SYSTEM  GRIDDLE
REMARKS: ______________________________________________ TOP-SIDE COOKER HOT PLATE PASTA PLUS
I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTIONS.
SIGNED: __________________________________________________________________________________ DATE:__________________________
Serving Those Who Serve The Very Best
SERVICE INFORMATION
If you have a service related question call 1-800-KEATING.
Please state the nature of the call; it will ensure speaking with the appropriate person.
Have your serial and model number available when ordering parts.
KEATING OF CHICAGO, INC.
8901 West 50th Street, McCook, Illinois 60525-6001
Phone: (708) 246-3000 FAX: (708) 246-3100
Toll Free 1-800-KEATING (In U.S. and Canada)
www.keatingofchicago.com
Loading...