Kaz HHT-080, HHT-100 Manual

0 (0)
PERMANENT HEPA TOWER AIR PURIFIERS
For Model Series HHT-080 and HHT-100
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked
over by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when not in use.
4. To disconnect the model HHT-080 series air
purifiers, first turn the control to the OFF position, grip the plug and pull it from the wall outlet. To disconnect the model HHT-100 series air purifiers, press the Power button to turn the unit off, grip the plug and pull it from the wall outlet. Never pull by the cord.
5. Do not use any product with a damaged cord
or plug or if product malfunctions, is dropped or damaged in any manner. Keep the cord away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do
not cover with throw rugs. Arrange cord such that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or use
near water, in a bathroom, laundry area or other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter ventilation
or exhaust opening as this may cause electric shock or damage to the air purifier. Do not block air outlets or intakes.
13. Locate air purifier near the outlet and avoid
using an extension cord.
14. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
15. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
16. Do not sit, stand or place heavy objects on the
air purifier.
17. Disconnect power supply before servicing.
WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Air Purifier With Any Solid-State Speed Control Device.
YOUR AIR PURIFIER
Control Panel
HOW YOUR AIR PURIFIER WORKS
Rear
Grille
Pre-filter (1)
HEPA-
Type
Filters
(2)
This model air purifier incorporates a 3-stage cleaning
Fig. 1
system to help clean the air that passes through the filter in the unit (Fig. 1).
Stage 1: Washable Particle Pre-Filter Stage 2: 99% HEPA-Type Filter with antimicrobial treatment Stage 3: Electronic Ionizer
SET-UP
• Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any wall or furniture.
• When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should be used underneath to prevent permanent staining. This is especially important in homes with contamination from smoking or fireplaces.
INSTALL HEPA-TYPE FILTERS
The HEPA-Type Filters are supplied within the air purifier. They are wrapped to ensure purity.
• Turn-off and unplug the air purifier. While pressing on
Fig. 2a Fig. 2b
the notches along the rear grille, pull the grille towards you and remove it (See Fig. 2a & 2b). Gently push along the edge of the filter frame and pull forward. Repeat for the second filter.
• Remove protective wrap from the filters.
• Place back into the air purifier housing and snap filter grille into place.
OPERATION
Model HHT-080 Series Operation:
Fig. 3a
Fig. 3b
• Ensure the air purifier is plugged into a working electrical outlet and the Power Knob is turned to the OFF position.
• Start and run the air purifier on High for several minutes and then rotate the Power Knob to the desired cleaning level (Fig. 3a).
Model HHT-100 Series Operation:
• Ensure the air purifier is plugged into a working electrical
HHT-080 Series HHT-100 Series
outlet.
• Press the power button ( ) once. The unit will automatically start at medium power (Fig. 3b).
• Press the power button again to select a different cleaning level.
It is recommended you run your air purifier 24 hours a day to ensure continuous cleaning. Portable air purifiers are more effective in rooms where all doors and windows are closed.
IONIZER FEATURE
The Ionizer helps boost the performance of the air purifier
Fig. 4a
Fig. 4b
and helps freshen the air.
• Press the Ionizer Control button ( ) (Fig. 4a & 4b).The LED will illuminate. This will power the Ionizer on.
• To turn the Ionizer feature off, simply press the button again. The LED light will no longer be illuminated.
HHT-080 Series HHT-100 Series
ELECTRONIC FILTER CLEAN REMINDER
This model air purifier has an electronic filter check to remind you when to check and clean the HEPA­Type filters based on the air cleaner’s hours of use.
When the HEPA-Type filters need to be cleaned, the light will remain on until it is RESET. You may unplug the air
Fig. 5a Fig. 5b
Will illuminate when it is time to clean HEPA filters
cleaner without interrupting the filter check. A red LED light will illuminate when it is time to clean the
filter. You should periodically check the filter. Depending on
operating conditions, the filters should be cleaned every 6 months to a year.
To RESET the Electronic Filter Check:
HHT-080 Series HHT-100 Series
When the filter monitor light remains on, it is time to check/clean the HEPA-Type filters and reset the filter monitor, if needed. With the unit powered on, insert the tip of a ball-point pen or paperclip next to the LED filter check light and hold for approximately 5 seconds until the light turns off (Fig 5a & 5b). Depending upon your individual usage (environment and hours used), you may need to check and clean the filters more or less frequently. If the HEPA-Type filters are cleaned before the filter monitor light turns on, the filter monitor should be reset at the same time.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent upon the concentration of contaminates going through the system. High concentrations of contaminates such as dust, pet dander and smoking will reduce the useful performance of the filter.
NOTE: The HEPA-Type filters are not washable.
OSCILLATION FEATURE (MODEL HHT-100 SERIES)
To help circulate fresher, cleaner air through the room, this unit has an oscillation
Fig. 6
feature.
• To turn Oscillation on, simply press the Oscillation button ( ) (Fig. 6).
• To turn Oscillation Off, press the button again.
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTERCLEANING THE HEPA-TYPE FILTERS
The Honeywell models HHT-080 Series and HHT-100 Series are equipped with permanent HEPA-Type filters which never need replacement with normal use.
Fig. 7
To Clean Your HEPA-Type Filter:
• DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE HEPA-TYPE FILTER.
• To vacuum-clean the filter, hold the filter and run a vacuum cleaner with a nozzle or brush attachment along the filter to pick-up the dirt and particles (Fig. 7). Repeat along the entire surface of the HEPA-Type filter.
• Note the filter may still be discolored even after cleaning it. This is acceptable and will not affect performance.
• After vacuuming the filter, place it back into the air purifier housing and snap filter grille into place.
If you have difficulty cleaning the filter, please visit us at www.kaz.com or call us at 1-800-332-1110.
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
The stage 1 particle pre-filter helps pick up large airborne particles that enter
Fig. 8
the rear grille. This pre-filter can be periodically removed and shaken to clean it. Alternatively, it can be rinsed by hand under warm water (Fig. 8). Let the pre-filter air dry completely before inserting back into the unit. If you need to replace this item, please see Consumer Relations section on the next page.
FREQUENTLY ASKED QUESTIONSCLEANING AND STORAGE
We recommend that you clean the air purifier at least once a month and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, WAX POLISH, OR ANY
CHEMICAL SOLUTION.
If your Air Purifier will not be used for more than 30 days, we recommend:
• Remove the HEPA-Type Filters from the unit.
• Wrap the HEPA-Type Filters in an air tight plastic bag.
FREQUENTLY ASKED QUESTIONS
FREQUENTLY ASKED QUESTIONS
My Air Purifier is starting to make noise and the air output is less. What’s wrong?
The filters may be dirty. High amounts of contaminates can block the pores in the filter and stop the air from moving through it. Clean the Filters.
How long should I run my Air Purifier?
For best results, you should operate your Air Purifier 24 hours a day.This unit will be more effective when doors and windows are closed.
Can I wash my HEPA-Type filter?
No. Washing the HEPA-Type filter will destroy it.
ACCESSORIES AND REPLACEMENT FILTERS
To order replacement filters, visit our website at: www.kaz.com or call us at 1-800-332-1110. Washable Pre-Filter (T.3024): $5.25
HEPA Filter (N.0101): $40.00 - Note that two (2) filters are required.
CONSUMER RELATIONS
Mail questions or comments to:
Kaz, Incorporated Consumer Relations Dept. 250 Turnpike Road Southborough, MA 01772
Call us toll-free at: 1-800-332-1110 E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST, RETURN THE AIR PURIFIER TO THE ORIGINAL PLACE OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY.
5 YEAR LIMITED WARRANTY
You should first read all instructions before attempting to use this product.
A. This 5 year limited warranty applies to repair or
replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not
allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in material or workmanship. Defective product should be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.
D. This warranty DOES NOT cover the washable
pre-filter or the HEPA filters, except for material or workmanship defects.
E. Return defective product to Kaz, Incorporated
with a brief description of the problem. Include proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number.You must prepay shipping charges. Send to:
In U.S.A.:
Kaz, Incorporated Attn: Returns Department 4755 Southpoint Drive Memphis, TN 38118 USA
In Canada:
Kaz, Incorporated Attn: Returns Department 510 Bronte Street South Milton, ON L9T 2X6 Canada
C. This warranty does not cover damage resulting
from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
Loading...
+ 14 hidden pages