Kason 11901A00005 Installation Manual

Installation:
1. The ideal location for the sensor is above door
aimed to 8’ in front of the doorway. To limit false tripping keep away from fans and vent ports. See “Sensor Set Up and Testing.”
2. Thread the ½ NPT arm into a threaded 90° elbow,
3. Connect the line voltage, neutral and load wires to
the sensor leads as shown in wiring diagram (pg. 2).
4. Test the sensor for sensitivity and range (pg. 2).
Sensor Assembly
This unit is pre-set based on typical walk-in applications for a 2 minute delay and 80% sensitivity. If your application requires alternate settings, simply remove the front cover (2 screws & seals) and make the necessary changes. Remember to reinstall the two screw seals when finished.
Factory Settings
1 2 PIR Sensitivity 3 4 5 Delay 6 7 8 Sensor
↓ ↓ 100% high ↓ ↓ ↓ 10 seconds ↓ ↓ ↓ (factory) ↓ ↑ 90% ↓ ↓ ↑ 20 seconds ↑ ↓ 80% (factory) ↓ ↑ ↓ 30 seconds ↑ ↑ 70% ↓ ↑ ↑ 1 minute
2 minutes (factory) 5 minutes 10 minutes 20 minutes
1
Specifications:
Voltage: 120 / 277 VAC @ 60 Hz Load: 120 VAC / 0- 800W ballast 277 VAC / 0-1200W ballast Time Delay: 10 seconds – 20 minutes Size: 4”H x 4”W x 2.16”D [102.58cm*102.58cm*55cm] Weight: 0.5 lbs [227 grams] Temperature:
Min: -20 F [-28.9 C] Max: 160 F [60 C] Electrical Connection: ½” conduit connection 18” 18 AWG wire
IP 65 Wire temperature 105 deg C max *
cULus Wet location -Indoor Use Only
NSF Protective Device:
A fast blow fuse or circuit breaker
mounted within 25 feet from sensor (Line
side) is required.
*Some incandescent fixtures may require higher temperature wires. Remote mounting or adding fiberglass sleeves over the wires may be required.
WARNINGS AND CAUTIONS:
Special Note from the field:
Always disable any existing light switches. The motion sensor will not function as intended if the customer can turn the circuit off or has the ability to override the motion sensor.
All installation must comply with local and National Electrical Codes. The manufacturer assumes no responsibility for improper installation or application. Turn off electricity at the breaker or fuse box before installation.
IS-1901 R6 12/15/14
Sensor Set Up and Testing
Fig. 1
Wiring for Single
Replacement Parts List:
11901A00005 Low Bay sensor module (up to 20’)
11901000009 Wall mounting kit with cord grip
To order additional sensors or replacements parts, please contact your local Kason representative www.kasonind.com
2
Location:
Sensor should be placed above the door. Sensor should be angled toward the center of the room without any obstructions. Sensor lens is designed to work in zones. If occupant crosses a zone the sensor will turn the lights on. Zones are represented by the rings on the floor in (Fig. 1).
Testing:
Allow a few minutes for the sensor to warm up then ENTER room. The sensor is equipped with a “Red LED” indicator that will activate when motion is sensed. Make note where the sensor sees motion and turns on the light. Repeat movement after allowing lights to turn off. Adjust sensor head for best room coverage. If the LED indicator is not visible then wait for the lights to go off. Additional sensor may be required for large / long rooms.
IS-1901 R6 12/15/14