Küppersbusch EM6-EM10, EMD1000, EMA1000, EMA800 Instructions For Use And Installation Instructions

EM6-EM10 EMD1000 EMA800-EMA1000
04301784/5
BEDIENUNGSANWEISUNG
mit Montageanweisungen
GB
Instructions for use and installation instructions Instructions d'utilisation e avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de Uso e Instrucciones de Montaje Bruksanvisning i monteringanvisningar Instruções de uso com indicações para montagem
F
NL
I E S P
Küppersbusch Hausgeräte AG
Postfach 10 01 32, D-45801 Gelsenkirchen, Küppersbuschstr. 16, D-45883 Gelsenkirchen
Telefon: (02 09) 4 01-0, Telefax: (02 09) 4 01-3 03
www.kueppersbusch.de
Küppersbusch Ges.m.b.H.
Eitnergasse 13, 1231 Wien, Telefon: 01 / 8 66 80-0, Telefax: 01 / 8 66 80 72
WARNING
--------------------------------------------------
The air collected must not be conveyed into a duct used to blow off smokes from ap­pliances fed with an energy other than electricity (central heating systems, ther­mosiphons, water-heaters, etc.).
Comply with the official instructions provided by the competent authorities in merit when installing the disposal duct. In addition, exhaust air should not be discharged into a wall cavity, unless the cavity is designed for that purpose.
The room must be well aerated in case a hood and some other heat equipment fed with an energy other than electricity (gas, oil, coal heaters, etc) operate at the same time. In fact the intake hood, disposing of air, could create a vacuum in the room. The vacuum should not exceed 0,04mbar. This prevents the gas exhausted by the heat source from being intaken again. It is therefore advisable to ensure the room contains air taps able to ensure a steady flow of fresh air.
ATTENTION: This appliance must be grounded.
The following warning is valid in the United Kingdom only: As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: – the wire which is coloured green and
yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol [ ], or co­loured green or green and yellow;
– the wire which is coloured blue must be
connected to the terminal which is marked with the letter N or coloured black;
– the wire which is coloured brown must be
connected to the terminal which is marked with the letter L or coloured red.
When making the electrical connections, check that the current socket has a ground connection and that the voltage values
English
correspond to those indicated on the data plate inside the appliance itself. In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensu­ring omnipolar disconnection from the elec­tricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation.
Always switch off the electricity supply be­fore carrying out any cleaning or servicing operations on the appliance.
Thorough servicing guarantees correct and long-lasting operation.
To get optimal conditions the air venting pipe should: – be as short as possible. – have the lowest number of bends (max bende angle: 90°). – be made of material approved by local authorities (according to the State). – have its inner side as regular and smooth as possible. It is moreover recommended to avoid drastic changes of pipe cross section (recommended diameter: 150 mm).
MODEL EM6 - EM10 (Fig. 1)
--------------------------------------------------
This apparatus has been specially studied to most efficiently and silently intake the kitchen vapors and odors. The apparatus must be installed inside the building and can be connected to a hood situated in the kitchen (Fig. 2).
Wall or ceiling fixing: unscrew the 7 screws A (Fig. 3) and take out the motor element. Fix the motor element onto the wall (or the ceiling, or onto any bearing), by means of the supplied 4 screws B and screw anchors (Fig. 4). Make the connection to the mains as indicated in the paragraph “electrical connection”. When it is connected close the apparatus.
Floor fixing: unscrew the 7 screws A (Fig. 3) and take out the motor element. Before fixing connect to the mains as indicated in the paragraph “electrical connection”. When it is connected, fix bracket S onto the apparatus (Fig.5). The bracket is supplied and can be fixed onto the apparatus in two any points P, minding that the cable is positioned on the right side. Close the apparatus and fix it onto the floor by
means of the bracket you assembled before
(Fig.6).
Air venting pipe connection (Fig. 7): fix 2 air
venting pipes at the two air outlets of the
apparatus by means of the metal clamps. The
elements (pipe and clamp) are at installer’s
charge. A pipe must be connected to the hood
set in the kitcken, the other one must be directed
toward the outside of the building.
Electrical connection: Direct electrical con-
nection: the input cable must be connected
directly to the electrical voltage, (therefore the
apparatus will always work at the maximum
speed) fixing the electrical cable of the apparatus
directly to the current tap (socket) connected to
a normal ON/OFF switch. Electrical connection
to a hood: (Fig. 7). The input cable must be
connected to the hood. Find out the box F (placed
on the hood) for connecting the hood to the
mains. Take off the cable clamp A and the cover
B of the connection box. Fix the cable to the
terminal board C. Reassemble the cable clamp
A and the cover B of the connection box.
MODEL EMA800 - EMA1000 (Fig. 8)
--------------------------------------------------
This apparatus has been specially studied to
most efficiently and silently intake the kitchen
vapors and odors. This apparatus can be set
outside and connected to a hood in a kitchen
(Fig. 9).
Outside wall fixing: take the boring template
and put it against the outside wall, positioning it
exactly where you are going to install the
apparatus. Mark onto the wall all the holes that
are indicated on the sheet. Make all the holes
into the wall. Fix the apparatus onto the wall by
means of the supplied 4 screws A and screw
anchors (Fig. 10).
Air venting pipe connection (Fig. 11): Fix a
pipe at the air outlet of the apparatus by means
of a metal clamp. The elements (pipe and clamp)
are at installer’s charge.
The pipe must pass inside the two metal
telescopic pipes T (that are supplied). Connect
the pipe to the hood that is in the kitchen.
Electrical connection: insert the input cable into
the plastic rigid pipe W (supplied), so that the
cable is protected while it goes into the wall
(Fig.11). Direct electrical connection: the input
cable must be connected directly to the electrical
voltage (therefore the apparatus will always work
at the maximum speed) fixing the electrical cable of the apparatus directly to the current tap (socket) connected to a normal ON/OFF switch. Electrical connection to a hood: (Fig. 12). The input cable must be connected to a hood. Find out the box F (placed on the hood) for connecting the hood to the mains. Take off the cable clamp A and the cover B from the connection box. Fix the cable to the terminal board C. Reassemble the cable clamp A and the cover B of the connection box.
MODEL EMD1000 (Fig. 13)
--------------------------------------------------
This apparatus has been specially studied to most efficiently and silently intake the kitchen vapors and odors. It must be installed onto the roof only and connected to a hood that is in the kitchen (Fig. 14).
Roof fixing: make a square opening into the roof that measures 22 x 22 cm. Insert a pipe into the opening your have just made (Fig. 15). Place also the 2 squares Q as indicated in Fig.16 and mark the holes you have to make into the pipe and onto the inside of the roof. Make all the holes and tightly fix the pipe. Now take the apparatus, insert it into the pipe and fix it by means of the 8 supplied screws (Fig. 17).
Air venting pipe connection (Fig. 14): fix a pipe at the air outlet of the apparatus by means of a metal clamp. The elements (pipe and clamp) are at installer’s charge. Connect the pipe to the hood that is in the kitchen.
Electrical connection: Direct electrical con­nection: the input cable must be connected directly to the electrical voltage (therefore the apparatus will always work at the maximum speed) fixing the electrical cable of the apparatus directly to the current tap (socket) connected to a normal ON/OFF switch. Electrical connection to a hood: (Fig.18). The input cable must be connected to a hood. Find out the box F (placed on the hood) for connecting the hood to the mains. Take off the cable clamp A and the cover B from the connection box. Fix the cable to the terminal board C. Reassemble the cable clamp A and the cover B of the connection box.
For the maintenance of the apparatus remove the metal cover unscrewing the 2 screws B (Fig.10).
Loading...
+ 2 hidden pages