Küppersbusch EKWI 3740.O W Installation Instructions Manual

MONTAGEANWEISUNGEN
Installation instructions
Manuel d’installation
Montagehandleiding
10
SUMMARY
DESCRIPTION OF THE APPLIANCE ....................................................................................... 11
A
PPLIANCES AND INSTALLATION DIMENSIONS ............................................................................... 11
MULTIZONES INSTALLATION ................................................................................................ 12
INSTALLATION ........................................................................................................................... 12
VENTILATION ............................................................................................................................ 12
INSTALLATION INSTRUCTIONS ..................................................................................................... 13
CONNEXION OF THE DIFFERENT ELEMENTS ...................................................................... 13
CONNECTION OF COOKING ZONES .............................................................................................. 13
CONFIGURATION PROCEDURE ............................................................................................. 15
WHAT TO DO IN CASE OF A PROBLEM ................................................................................ 15
ELECTRICAL CONNECTION ................................................................................................... 16
11
DESCRIPTION OF THE APPLIANCE
Appliances and installation dimensions
Dimension
Heating zone Finger touch
5 7 C
Reference 703879-02 703879-03
703879-01 703880-01
Dimension of
glass
A 320mm 320mm
Diameter of the
throat
B 326mm 326mm
Thickness of
glass
4mm 4mm
Cut-out Dimen-
sion
C 302mm 180 x 113 mm
Height total 57mm 35mm
Diameter of the
inductor
160mm 200mm
Power 1100W 2300W
Booster 2500W 3000W
Dimensions of the technical box 703879-04 : 260x211x48