JVC UXN-1 Service manual

SERVICE MANUAL
MICRO COMPONENT SYSTEM
MB53920066
UX-N1SA,UX-N1SUS,UX-N1SUB,
UX-N1SUF,UX-N1SUP,UX-N1SUT, UX-N1SUW,UX-N1SUY,UX-N1SUJ, UX-N1WA,UX-N1WUS,UX-N1WUB,
UX-N1WUF,UX-N1WUP,UX-N1WUT,
UX-N1WUW,UX-N1WUJ
IN LINE OUT
for DIGIATL AUDIO PLAYER
CA-UXN1S CA-UXN1W SP-UXN1WSP-UXN1W
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
TABLE OF CONTENTS
1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
3 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
4 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
5 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
COPYRIGHT © 2006 Victor Company of Japan, Limited
SP-UXN1SSP-UXN1S
No.MB539
2006/6
SPECIFICATION
Amplifier section OUTPUT POWER 10 W (5 W + 5 W) at 4 (10% THD)
Speakers/Impedance 4 - 16 Audio Input : LINE IN 500 mV/47 k (at "LINE IN LVL1")
250 mV/47 k (at "LINE IN LVL2") 125 mV/47 k (at "LINE IN LVL3")
Audio output : LINE OUT 1.0 Vrms (47 k) (at "LINE OUT LVL1")
2.0 Vrms (47 k) (at "LINE OUT LVL2")
Tuner section FM Tuning range 87.50 MHz - 108.00 MHz
AM Tuning range 530 kHz - 1 710 kHz (in 10 kHz spacing)
531 kHz - 1 710 kHz (in 9 kHz spacing)
CD player section Dynamic range 88 dB
Signal-to-noise ratio 93 dB
Wow and flutter Immeasurable
Speakers Speaker units 8 cm cone × 1
Impedance 4 Dimensions (approx.) (W/H/D) 130 mm × 171 mm × 136 mm
Mass (approx.) 0.75 kg each
General Power requirements AC 110/220 - 240 V (adjustable with the voltage selector except for Hong Kong
and Australia), 50/60 Hz AC 240 V , 50 Hz (only Australia) AC 220 V , 50 Hz (only Hong Kong)
Power consumption 21.0 W (Power on)
5.0 W (Standby mode)
4.5 W or less (Save mode)
Dimensions (W/H/D) 270 mm × 68.5 mm × 203 mm
Mass 1.8 kg
Design and specifications are subject to change without notice.
1-2 (No.MB539)
SECTION 1
PRECAUTION
1.1 Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purpos­es. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be per­formed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteris­tics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by us­ing replacement components rated for higher voltage, watt­age, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Ser­vice Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety charac­teristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after reassem­bling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isola­tion check on the exposed metal parts of the product (an­tenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock.Do not use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a "Leakage Current Tester", measure the leakage current from each exposed metal parts of the cabinet, particular­ly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage cur­rent must not exceed 0.5mA AC (r.m.s.).
• Alternate check method Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000 per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15µF AC-type capacitor between an ex-
posed metal part and a known good earth ground. Measure the AC voltage across the resistor with the AC
voltmeter. Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and measure the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.).
AC VOLTMETER (Having 1000 ohms/volts, or more sensitivity)
0.15 F AC TYPE
Place this probe on
1500 10W
Good earth ground
1.2 Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3 Caution
Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burrs in the case of pre­forming repair of this system.
1.4 Critical parts for safety
In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the " " mark nearby are critical for safety. When replacing them, be sure to use the parts of the same type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)
each exposed metal part.
(No.MB539)1-3
1.5 Important for laser products
1.CLASS 1 LASER PRODUCT
2.CAUTION :
(For U.S.A.) Visible and/or invisible class II laser radiation when open. Do not stare into beam. (Others) Visible and/or invisible class 1M laser radiation when open. Do not view directly with optical instruments.
3.CAUTION : Visible and/or invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam.
4.CAUTION : This laser product uses visible and/or invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat the safety switches.
5.CAUTION : If safety switches malfunction, the laser is able to function.
6.CAUTION : Use of controls, adjustments or performance of procedures other than those specified here in may result in hazardous radiation exposure.
!
Please use enough caution not to
see the beam directly or touch it
in case of an adjustment or operation
check.
REPRODUCTION AND POSITION OF LABELS and PRINT
WARNING LABEL and PRINT
CLASS 1 LASER PRODUCT
1-4 (No.MB539)
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 3
DISASSEMBLY
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 4
ADJUSTMENT
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 5
TROUBLESHOOTING
Please refer to "UX-N1 (No.MB514)" about this section.
(No.MB539)1-5
Victor Company of Japan, Limited Audio/Video Systems Category 10-1,1chome,Ohwatari-machi,Maebashi-city,371-8543,Japan
(No.MB539)
Printed in Japan
VPT
SCHEMATIC DIAGRAMS
MICRO COMPONENT SYSTEM
UX-N1SA,UX-N1SUS,UX-N1SUB
UX-N1SUF,UX-N1SUP,UX-N1SUT
UX-N1SUW,UX-N1SUY,UX-N1SUJ
UX-N1WA,UX-N1WUS,UX-N1WUB
UX-N1WUF,UX-N1WUP,UX-N1WUT
UX-N1WUW,UX-N1WUJ
CD-ROM No.SML200606
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
Contents
Block diagrams Standard schematic diagrams Printed circuit boards
COPYRIGHT 2006 Victor Company of Japan, Limited.
IN LINE OUT
for DIGIATL AUDIO PLAYER
CA-UXN1S CA-UXN1W SP-UXN1WSP-UXN1W
SP-UXN1SSP-UXN1S
2-1 2-2 2-6 to 8
No.MB539SCH
2006/6
In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the " " mark nearby are critical for safety.
Block diagram
CD traverse mechanism
CD pickup mechanism
TOUCH SENSOR
CD servo control section System control section
SP+/-
CN602
TRV+/-
CDSW
FO+/­TR+/-
CN601
IC601
FOCUS
TRACKING
SPINDLE
FEED
BTL. AMP.
TRVP SPOUT TRP FOP
A+C B+D E, F LD, PD
IC602
DSP
MLD, MDATA, MCLK CDREST
IRQ STAT
IC604
BUFFER
CDL/R
IRQ STAT
OPEN CLOSE
E2CLK E2DATA
IC701
BUP BCTL
Touch sense section
SENSE CD SENSE FM/AM SENSE LINE OSC
IC401,IC402 Q4011,Q4012 Q4101,Q4201
Q4301
CD FM/AM LINE
CN431
CN432
Q4102 Q4202 Q4302
MICON
CD FM/AM LINEIN
SENSE AMP.
Key switch section
S2501 to S2508
KEY MATRIX
Q2501,Q2502
D2501 to D2503
LED
LCD section
DI221
LCD DISPLAY
COM1 to COM4 SG1 to SG38
IC221
KEY0 KEY4
TP.LED POUT
/INH LCDCS LCDCLK LCDDATA
CN702
CN251
CN701
CN221
KEY0 KEY4 TP.LED
/INH LCDCS LCDCLK LCDDATA REM LEDDIM
POUT
FAN1,FAN2, QPLINK, LVOL SMUTE, LMUTE SW10, FTU, FCD, SAFTY1,SAFTY2 VOLDATA, VOLCE, VOLCK, S.BASS TUCE, TUCLK,TUDI, TUDO
Used for Area suffix UP
LCD DRIVER
IC241
REMOCON
Q2411,D2411
STANDBY LED
Q2210,Q2202
D2201,D2202
REM
POUT
LEDDIM POUT
MOTOR1 MOTOR2
IC511
DOOR MOTOR DRIVER
BACK LIGHT
CN511
DOOR DRIVE
M
MOTOR
S7001
DOOR
DETECT
IC702
EEPROM
Q7002 Q7003
X7001
8MHz
Q7001
RESET
RDSCLK, RDSDAT
CD8V US6V
Main section Main section
(Terminal)
CN312
LOPOUT ROPOUT
Q3101,Q3201
Q3303
MUTING
SMUTE POUT
IC301
POWER AMP.
SAFTY1
Q3311
CN311
L+/­R+/-
Q3312
Q3601 Q3602
S.BASS
L5 R5
LSEL0 RSEL0
TUNERL/R
DAB6V
IC452,Q4501
QP LINK
QPLINK
Q4604 to Q4606
LINE VOLUME
IC451
LINE IN AMP.
Q4601 to Q4603
LINE MUTING
TUCE,TUCLK,TUDI,TUDO
RDSCLK, RDSDAT
Used for Area suffix UP
FAN1 FAN2
Q8101 to Q8104
FAN DRIVE
CN707
CN316
CN703
CN313
CDL CDR
FCD SAFTY2
IC303
E.VOLUME
VOLCE VOLCK VOLDATA
CD8V
Q3501,Q3502
CD8V REG.
TU9V
IC911
DAB6V REG.
FTU
Q3801,Q3802
US6V
TU9V REG.
CN704
CN314
SW10
SW9V
Q3401,Q3402
SW9V REG.
D1001
DIODE
BRIDGE
IC711
US6V REG.
CN102
T901 POWER TRANS.
Used for Area suffix A/UB/UF/UP
Used for Area suffix US/UT/UW/UY/UJ
CN105
S1001
VOLTAGE
SELECTOR
LMUTELVOL
CN104
CN103
J3301 J3001
TO HEADPHONE
TO SPEAKER
J4351
LINE IN
J4352
LINE OUT
CN911
TUNER UNIT
CN811
M
CN101
AC IN
FAN MOTOR
2-1
Standard schematic diagrams
Amplifier section
K4351
J4351
QNS0271-001
C4509
NI
J4352
QNS0271-001
R4508
R4509
C4508
NI
100K
IC451
NJM4565M-WE
100K
C4507
R4511
D4602
1SS133-T2
D4353
100P
1K
C4505
2.2/50
NI
Q8101
1SS133-T2
D4352
C4503
C4502
R4507
NI
100P
0
C4504
2.2/50
R4510 1K
D4601
C4506
R4601
C4601
C4602
NI
R8101
R8103 NI
R4602
47/16
47/16
0
47K
K4602
C3151
CN911 QGF1208C1-15
VCC9V
TUNERR
TUNERL
13K 13K
220P
220P
C4152
C4252
R4502
4.7K
4.7K
R4501
C4606
C4608C4609
10K
R8102
Q8102 2SA1530A/QR/-X
CN811 QGA2001C1-02
C4510
0.22
C4607
100PNI
R4603
R4604
R4605
2.2K
R4606
300
51K
R4152
300
NI
2.2K
100P
R8105
3.3V RDSCLK
51K
R4252
IC452
NJM4565M-WE
1K
Q8104
NI
RDSDAT
R4503
R4512
Q4501 RT1N44HC-X
15K
Q4603 RT1P441C-X
TUDO
TUCE
TUDI
TUCLK
C9004
1000p
R4251
R4151
NI
NI
C4151
C4251
R4506
47K
1K
2SC3661-X
Q4601
NINI
C4604C4605
470P
470P
1K
Q4602
2SC3661-X
NI
R8106
NI
R8104
51
K901 0
220K
1SS133-T2
R4505
2.2K
C4603 10/25
1K
Q8103
RT1N431C-X
R4607
D4501
10/25
C4501
B1104
C9002 1000P
B1106
R4614
R4615
4.7K
R3154
1K
C3149
10/25
C3342
4.7K
RT1P141C-X
Q4606
CDL
CDR
100K
R4504
R4608
47K
3.6K
R4612
R4610
3.3K
Q4604
2SC3661-X
R4609
47K
R4613
3.6K
Q4605
2SC3661-X
3.3K
R4611
R8107
R8108
220/10
C3249
R3254
10/25
1K
R3152
R3155
R3149
3.3K
4.7/50
R3141
15k
7.5K
1K
R3150 C3156
R3151
1K
C3148
0.1/50
C3248
R3252
0.1/50
1K
C3145
R3255
C3251
4.7/50 C3157
390P
C3245
R3251
4.7/50
1K
C3155
C3256
4.7/50
C3257
R3250
4.7/50
C3144
C3143
0.1
0.0027
0.0027
C3244
4.7/50
390P
C3255
15k
3.3K
R3249
1SS133-T2
D3502
0.1
C3243
R3503
C3142
39K
R3504
18K
R3140 NI
0.1
R3241
NI
C3141
IC303
LC75345M-X
0.1
C3242
C3241
7.5k
C3503 100/16
NI
C3140
R3146
C3240
NI
NI
R3240
D3501 MTZJ5.6A-T2
R3147
6.2K
C3154
0.47
C3153
1.8K
R3246
NI
0.068
C3152
1.8k
R3148
C3502
0.01
R3502
220K
R3247
6.2k
270
R3248
C3253
C3254
0.47
0.068
220K
0.068
R3143
22K
2.2K
1.5K
R3145
R3144
C3150
22/16
0.068
C3252
C3250
1.5k
R3245
R3243
Q3501
KTB772/Y/
1SS133-T2
Q3502 2SC3928A/QR/-X
C3501
10/25
R3142
47K
Q3602 2SC3661-X
R3342
4.7K VOLCE
VOLDATA
4.7K
R3343
4.7K
R3344
VOLCK
D3306
100
22/16
C3341
R3341
220/10
2.2k
R3244
Q3601 R3242
22K
2SC3661-X
R3510
R3508 R3506
R3507
10
D3503
R3501
6.8K
R3505
S.BASS
R3310
22K
47K
R3509
10
FTU
SAFTY1
SW10
1SS133-T2
C3312 10/25
C3802 100/16
C9103
0.1
D3305 1SS133-T2
C3801
Q3803
RT1P430C-X
D3802
IC911
C9102
100/16
R3803
R3309 120K
R3308
220K
D3801
Q3804
RT1N141C-X
C9101
0.1
C3311
1/50
R3305
Q3801 KTB772/Y/
C3803
MTZJ5.6B-T2
R3801 20K
R3802 470
10K
POUT
0.01
D7102
2SA1530A/QR/-X
R3411R3412
Q3802
2SC3928A/QR/-X
D3403
3.6K
1SS133-T2
1SS133-T2
MTZJ8.2B-T2
9.1K
D7101
C3404
D1001
R3206
R3106
Q3303
100/16
R3306
5.6K
C3310 22/16
FL402
6.8K
6.8K
SMUTE
D3402
MTZJ6.2B-T2
C7103
NI
C3209
Q3201
2SC3661-X
2.2K
R3205
470P
C3211
RT1N141C-X
Q3401
C3402
0.01
Q3402
2SC3928A/QR/-X
R3401
470
IC711
C7102
100/16
0.1
NI
C3210
C3401 10/25
NI
C3109
2.2K
C3111
R3105
D3302
1SS133-T2
Q3312
Q3101
2SC3661-X
470P
C3309
0.1/50
C7101
0.1
C3208 10/35
C3108 10/35
NI
C3110
47K
R3204
D3401
1SS133-T2
R3402
6.8K
R3209
1K
R3109
1K
18K
18K
R3203
47K
R3103
1/50
C3305
R3104
R3301
4.7K
C3313 22u/25V
R3403
R3405 R3406
R3202
100/16
C3206
KTA1267/YG/-T
R3312 68k
R3805 R3804
R3806
820
330P
Q3311
C3207
330P
C3107
R3102
100/16
C3106
C9003
0.0033
R3404
NI
IC301 BA5417
820
220/16
C3304
R3807
47/16
C3303
C3105
R1003
C3104
R3101
2.2
0.022
C3204
100/16
C3101
22/16
0.1
C3302
R3311
0.22
TH101 QAD0159-001
100/16
C3102
2200/16
C3205
6800/25
R3307
C3301
C3202
22/16
C3201
0.022
2.2
R3201
CN311
QGB2510J1-04
D1003
2200/16
C3213
CN312
QGB2510K2-04
C9001
220P
QQR0797-002
0.001
C3113 220P
L3202
C3112
R3108
R3208
J3301
QNS0272-001
4.7u
L3101
120 120
L3201
4.7u
NI
NI
C3212
K3301
NQR0502-002X
L3102
QQR0797-002
C3214
J3001
3300P
R+ R-
L+ L-
C3114 3300P
FAN1
POUT
FAN2
CN313
QGF1040C1-23
VOLCK
S.BASS
TUCE
SMUTE
TUDO
SAFTY2
R1001
LF101
QQR1645-001
C1003
!
F1001
QMF51W2-R20-J8
CN101 QGA7901F1-02
C1001
CDR
T901
CDL
CN316
QJP007-031700-E
QQT0512-002
QPLINK
LVOL
VOLCE
SW10
RDSDAT
SAFTY1
VOLDATA
FTU
RDSCLK
FCD
TUDI
TUCLK
T901
QQT0513-001
LMUTE
US6V
CD8V
CN314
QGA2001C1-05
!!!
T901T901
QQQT0511-001QQT0512-001
T901
QQT0511-002
0.01
CN105
QGA7901C1-03
C1004
0.01
C1005
0.01
CN102
S1001
QSW1190-001
QGA3901C1-02
QGA7901C1-02
C1008
0.01
CN103
CN104
Q1001
D1002
C1006
RY101
C1007
Parts are safety assurance parts. When replacing those parts make sure to use the specified one.
2-2
Loading...
+ 21 hidden pages