AM Tuning range530 kHz - 1 710 kHz (in 10 kHz spacing)
531 kHz - 1 710 kHz (in 9 kHz spacing)
CD player section Dynamic range88 dB
Signal-to-noise ratio93 dB
Wow and flutterImmeasurable
SpeakersSpeaker units8 cm cone × 1
Impedance4 Ω
Dimensions (approx.) (W/H/D) 130 mm × 171 mm × 136 mm
Mass (approx.)0.75 kg each
GeneralPower requirementsAC 110/220 - 240 V (adjustable with the voltage selector except for Hong Kong
and Australia), 50/60 Hz
AC 240 V , 50 Hz (only Australia)
AC 220 V , 50 Hz (only Hong Kong)
Power consumption21.0 W (Power on)
5.0 W (Standby mode)
4.5 W or less (Save mode)
Dimensions (W/H/D)270 mm × 68.5 mm × 203 mm
Mass1.8 kg
Design and specifications are subject to change without notice.
1-2 (No.MB539)
SECTION 1
PRECAUTION
1.1Safety Precautions
(1) This design of this product contains special hardware and
many circuits and components specially for safety purposes. For continued protection, no changes should be made
to the original design unless authorized in writing by the
manufacturer. Replacement parts must be identical to
those used in the original circuits. Services should be performed by qualified personnel only.
(2) Alterations of the design or circuitry of the product should
not be made. Any design alterations of the product should
not be made. Any design alterations or additions will void
the manufacturers warranty and will further relieve the
manufacture of responsibility for personal injury or property
damage resulting therefrom.
(3) Many electrical and mechanical parts in the products have
special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the
protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special
safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features
are identified by shading on the schematics and by ( ) on
the Parts List in the Service Manual. The use of a substitute
replacement which does not have the same safety characteristics as the recommended replacement parts shown in
the Parts List of Service Manual may create shock, fire, or
other hazards.
(4) The leads in the products are routed and dressed with ties,
clamps, tubings, barriers and the like to be separated from
live parts, high temperature parts, moving parts and/or
sharp edges for the prevention of electric shock and fire
hazard. When service is required, the original lead routing
and dress should be observed, and it should be confirmed
that they have been returned to normal, after reassembling.
(5) Leakage shock hazard testing
After reassembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads,
headphone jack, control shafts, etc.) to be sure the product
is safe to operate without danger of electrical shock.Do not
use a line isolation transformer during this check.
• Plug the AC line cord directly into the AC outlet. Using a
"Leakage Current Tester", measure the leakage current
from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the
chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.).
• Alternate check method
Plug the AC line cord directly into the AC outlet. Use an
AC voltmeter having, 1,000Ω per volt or more sensitivity
in the following manner. Connect a 1,500Ω 10W resistor
paralleled by a 0.15µF AC-type capacitor between an ex-
posed metal part and a known good earth ground.
Measure the AC voltage across the resistor with the AC
voltmeter.
Move the resistor connection to each exposed metal
part, particularly any exposed metal part having a return
path to the chassis, and measure the AC voltage across
the resistor. Now, reverse the plug in the AC outlet and
repeat each measurement. Voltage measured any must
not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5
mA AC (r.m.s.).
AC VOLTMETER
(Having 1000
ohms/volts,
or more sensitivity)
0.15 F AC TYPE
Place this
probe on
1500 10W
Good earth ground
1.2Warning
(1) This equipment has been designed and manufactured to
meet international safety standards.
(2) It is the legal responsibility of the repairer to ensure that
these safety standards are maintained.
(3) Repairs must be made in accordance with the relevant
safety standards.
(4) It is essential that safety critical components are replaced
by approved parts.
(5) If mains voltage selector is provided, check setting for local
voltage.
1.3Caution
Burrs formed during molding may be left over on some parts
of the chassis.
Therefore, pay attention to such burrs in the case of preforming repair of this system.
1.4Critical parts for safety
In regard with component parts appearing on the silk-screen
printed side (parts side) of the PWB diagrams, the parts that are
printed over with black such as the resistor ( ), diode ( )
and ICP ( ) or identified by the " " mark nearby are critical
for safety. When replacing them, be sure to use the parts of the
same type and rating as specified by the manufacturer.
(This regulation dose not Except the J and C version)
each exposed
metal part.
(No.MB539)1-3
1.5Important for laser products
1.CLASS 1 LASER PRODUCT
2.CAUTION :
(For U.S.A.) Visible and/or invisible class II laser radiation
when open. Do not stare into beam.
(Others) Visible and/or invisible class 1M laser radiation
when open. Do not view directly with optical instruments.
3.CAUTION : Visible and/or invisible laser radiation when
open and inter lock failed or defeated. Avoid direct
exposure to beam.
4.CAUTION : This laser product uses visible and/or invisible
laser radiation and is equipped with safety switches which
prevent emission of radiation when the drawer is open and
the safety interlocks have failed or are defeated. It is
dangerous to defeat the safety switches.
5.CAUTION : If safety switches malfunction, the laser is able
to function.
6.CAUTION : Use of controls, adjustments or performance of
procedures other than those specified here in may result in
hazardous radiation exposure.
!
Please use enough caution not to
see the beam directly or touch it
in case of an adjustment or operation
check.
REPRODUCTION AND POSITION OF LABELS and PRINT
WARNING LABEL and PRINT
CLASS 1
LASER PRODUCT
1-4 (No.MB539)
SECTION 2
SPECIFIC SERVICE INSTRUCTIONS
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 3
DISASSEMBLY
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 4
ADJUSTMENT
Please refer to "UX-N1 (No.MB514)" about this section.
SECTION 5
TROUBLESHOOTING
Please refer to "UX-N1 (No.MB514)" about this section.
(No.MB539)1-5
Victor Company of Japan, Limited
Audio/Video Systems Category 10-1,1chome,Ohwatari-machi,Maebashi-city,371-8543,Japan
(No.MB539)
Printed in Japan
VPT
SCHEMATIC DIAGRAMS
MICRO COMPONENT SYSTEM
UX-N1SA,UX-N1SUS,UX-N1SUB
UX-N1SUF,UX-N1SUP,UX-N1SUT
UX-N1SUW,UX-N1SUY,UX-N1SUJ
UX-N1WA,UX-N1WUS,UX-N1WUB
UX-N1WUF,UX-N1WUP,UX-N1WUT
UX-N1WUW,UX-N1WUJ
CD-ROM No.SML200606
Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)
Contents
Block diagrams
Standard schematic diagrams
Printed circuit boards
COPYRIGHT 2006 Victor Company of Japan, Limited.
IN LINE OUT
for DIGIATL AUDIO PLAYER
CA-UXN1S
CA-UXN1WSP-UXN1WSP-UXN1W
SP-UXN1SSP-UXN1S
2-1
2-2
2-6 to 8
No.MB539SCH
2006/6
In regard with component parts appearing on the silk-screen printed side (parts side) of the PWB diagrams, the
parts that are printed over with black such as the resistor ( ), diode ( ) and ICP ( ) or identified by the " "
mark nearby are critical for safety.