JVC TK-C700U - Color Cctv Camera, TK-C675B Instructions Manual

Page 1
TK-C675B
COMBINATION CAMERA
INSTRUCTIONS
For Customer Use :
Enter below the Serial No. which is located on the body. Retain this information for future reference.
Model No. TK-C675B Serial No.
This instruction book is made from 100% recycled paper.
LOCK
RELEASE
Page 2
2
For USA and CANADA
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor­tant operating and maintenance (servicing) instruc­tions in the literature accompanying the appliance.
The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magni­tude to constitute a risk of electric shock to persons.
Information for USA
This device complies with Part 15 of the FCC Rules. Changes or modifications not approved by JVC could v oid the user's authority to operate the equipment.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
AVERTISSEMENT: POUR EVITER LES RISQUES D'INCENDIE OU D'ELECTROCUTION, NE PAS EXPOSER L'APPAREIL A L'HUMIDITE OU A LA PLUIE.
FEATURES ......................................................................... 2
OPERATING PRECAUTIONS............................................. 3
SAFETY PRECAUTIONS ................................................... 3
CONTROLS, CONNECTORS AND INDICATORS.............. 4
INSTALLATION ................................................................... 5
CONNECTIONS.................................................................. 8
HOW TO USE THE FERRITE CORE.................................. 9
MENU SETTINGS............................................................. 10
Menu operations ............................................................... 10
Menu screen flow .............................................................. 11
CAMERA MODE SELECT screen .................................... 12
CAMERA VIDEO ADJUST screen.................................... 13
VIDEO ADJUST FOR POSITION screen ......................... 14
POSITION TEXT screen ................................................... 15
CAMERA TEXT screen ..................................................... 16
AREA TEXT screen .......................................................... 17
ALARM TEXT screen ........................................................ 18
AUTO PAN SET screen..................................................... 19
AUTO PATROL SETUP screen ......................................... 20
F ACTORY SETTINGS screen........................................... 21
TROUBLESHOOTING ...................................................... 22
SPECIFICATIONS............................................................. 23
Due to design modifications, data given in this instruction book are subject to possible change without prior notice.
CAUTION
INFORMATION (FOR CANADA) RENSEIGNEMENT (POUR CANADA)
Cet appareil numénque de la classe [B] respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.
This Class [B] digital apparatus meets all requirements of the canadian Interference-Causing Equipment Regulations.
FEATURES
m Features large aper ture lens with 16x zoom ratio (f=4.5 to
72mm, F1.2, at wide angle).
m Wide co verage angle (Horizontal 3.8° to 56°, Vertical 2.9° to
44°).
m 64 preset positions . m 360 degree endless panning. m Maxim um 240 degree/sec. panning speed. m Maxim um 2-second z oom speed. m One-push auto focus capability. m RS-485 (Maximum Number of Connections: 32) or RS-422A
control signal.
m High-quality pictures by adopting dome cover with optical
distortion compensation and CCD with 380,000 (U: type) or 440,000 (E: type) effective pixels.
m Adopts large aperture lens, highly sensitive CCD.
(Minimum illumination : 2.8 lx, at wide angle)
m Auto panning function. m Variable panning speed.
The panning speed is varied automatically according to the zoom ratio of the lens. (The panning speed decreases when the zoom lens is set near TELE and increases when it is set near WIDE.)
m Auto flip
When the camera reaches its tilting limit, it automatically flips itself over by 180 degrees by panning around.
(This makes it possible for the camera to continue tilting even after it has been tilted straight downward.)
mAuto patrol
Preset positions are activated in sequence. m Menu screen display A built-in character generator provides an on-screen menu
display for easy selection and setting of various functions. m 5-language on-screen display
Names or designations for camera, preset, area and alarm
can be displayed in English, German, F rench, Italian and
Spanish. (E type only) m Area title indication The 360˚ panning angle (horizontal rotation) is divided into
16 sectors, allowing you to check the title in each area.
When the camera is manually panned, the preset area
designation is shown on the screen.
CONTENTS
Thank you for purchasing this product.
m Before starting an important recording, be sure to per-
form a test recording in order to confirm that a normal recording is possible.
m We do not accept liability for the loss of a recording in
the case of it becoming impossible to record due to a problem in the video camera, VCR or video tape.
m We do not accept liability for any damage to the cam-
era in cases when it is dropped because of incomplete installation due to not observing the installation instruc­tions correctly. Please be careful when installing the camera.
Page 3
3
Operating precautions
To save energy, when it is not being used turn the system's power off.
This camera has been designed for indoor use. It cannot be used outdoors.
This camera has been designed exclusively to be hung from the ceiling.It may malfunction if it is placed on a surface or if it is tilted.
Do not install or use the camera in the following places.
• In a place exposed to rain or moisture.
• In a place with vapor or oil soot, for example in a kitchen.
• In a temperature outside the operating temperature range
(–10°C to 50°C).
• Near a source of radiation, X-rays, strong radio waves or
magnetism.
• In a place subject to vibration.
• In a place with excessive dirt.
Insufficient head ventilation of the camera ma y cause a mal­function. Be careful not to block the ventilation to the camera.
If this camera and the cables connected to this camera are used where there are strong electromagnetic waves or where there is magnetism present, for example near a r adio or TV transmitter, pow er tr ansformer or an electric motor, the pic­ture may produce noise and the colors may be affected.
This camera incorporates an AGC circuit. As a result, when it is used under low light conditions, the camera sensitivity is automatically boosted and the picture may look uneven. This is not a malfunction however.
When the AGC is ON in the auto iris mode, varying the iris with the IRIS control button may not change the picture brightness due to the gain boost function. In this case, s witch the AGC OFF or set the iris mode to manual.
In auto iris mode, the IRIS control buttons may not function under certain brightness conditions (i.e. when a sufficient amount of light cannot be obtained). In this case , set the iris mode to manual.
The white balance setting when used under a fluorescent lamp should be A TW (A uto White). If it is set to MANU (Man­ual), the white balance may not be adjustable.
When presetting this unit’ s position, turn it on and wait until it has warmed up sufficiently inside (about 30 minutes). This is to avoid a change in the lens focus due to a rise in tem­perature after installation.
When this camera is used in the AUT O white balance mode, the recorded colors may be slightly different from the actual colors due to the operational principles of the auto-tracking white balance circuit. This is however not a malfunction.
If a high-intensity object (such as a lamp) is shot, the image on the screen may have v ertical lines (smear) or blur (bloom­ing) at its periphery. This is a characteristic of the CCD, and is not a defect.
The electronic shutter of this camera has been set to 1/60(1/
50) sec. at the factory. When the camera is used under a fluorescent lamp or in an area with a local power frequency of 50/60 Hz, change the shutter speed to 1/100(1/60) on the remote control unit. (The sensitivity deteriorates slightly with a shutter speed of less than 1/100(1/60) sec.) Utype (Etype)
When the camera is used to monitor the same position con­tinuously for 24 hours or more, the contact resistance of the horizontal rotary parts may increase after long hours of use, and the picture may be affected b y noise interference or the remote control operation may become unstable. To prevent this, turn the system power off and on at least once a week (to initialize) and also clean the contacts.
Do not touch the dome cover of the lens directly with your hand, contamination of this cover will lead to a deterioration of the picture quality.
Observe the following when carrying out camera mainte­nance.
• Turn the power OFF before proceeding to carry out main-
tenance.
• Clean the dome cover lens using a lens wiper cloth (or a
tissue). If it is contaminated seriously , clean the contaminated part with a cloth (or a tissue) which has been soaked in a solu­tion of water and a neutral detergent.
In order to reduce the generation of unnecessary signals, be sure to install the provided ferrite cores when connect­ing the cables. (See “How to use the f errite core” on page 9)
Some subjects may not be brought into focus with the auto­focus facility of this unit. Focusing will be made easier by locating a subject with highly contrasted vertical stripes near the center of the image.
Optional controller is required to use the TK-C675B cam­era. Please contact your local dealer or installer for more information about this controller.
Safety precautions
• As this unit contains parts which rotate at high speeds, it should be installed in a place suitable to withstand the pos­sible vibrations and to support the unit weight of 2 kg. If the ceiling is made of dressed-face plywood, plaster board or another material which is not strong enough to support the unit, reinforce the installed surface by using a reinforcing material (including plywood). If the reinforcement is insuffi­cient, the monitor picture may be blurred due to vibrations or in the worst case the unit may fall.
• Installation of this unit requires expertise. Please contact your dealer for details.
Caution during continuous use
Continuous use of the preset sequence or auto panning op­eration may make the service life much shorter than expect­ed. The guaranteed operation count for the zoom lens of this camera is around 400,000 times.
(Example)
24 hours of operation per day with single zoom operation per minute: 400,000 (times)/60 (minutes)/24 (hours) = 278 (da ys)
• The ceiling to mount the TK-C675B has to be strong enough to support ten times the weight of this product. If the ceiling is not strong enough, make sure to apply rein­forcement to the ceiling before installation.
• Be sure to tighten the screws and nuts securely, Insufficient tightening may cause the unit to fall from its mount.
• The unit is to be powered by an AC24V. Isolated power supply only. (E type) Class 2 only (U type)
Page 4
4
Controls, connectors and indicators
Ceiling mount Camera body
View when the camera body cover is removed
11
15
14
16
15
13
12
Camera position alignment mark
Dome cover lens
Dome cover
17
Ventilation
18
1
VIDEO OUTPUT terminal
Outputs composite video signals and is to be connected to a monitor, etc. (Output impedance 75ohm)
2
Control signal terminals
The camera can be controlled by RS-422A or RS-485 sig­nals.
3
AC 24V input terminals
Input the 24 V AC power. Isolated power only (E type) Class 2 only (U type)
4
Drop prevention wire
Engage this wire in the drop prevention wire hook
12
on
the camera.
5
Mounting holes (× 4)
Use these holes to attach the ceiling mount to the ceiling.
6
Camera connector (male)
Connects with the camera connector 13 on the camera.
7
Lock screw
Use this screw to fasten the camera clamp 14 to fix the camera.
8
Camera position alignment mark
Align with the mark 17 when mounting the camera onto the ceiling mount.
9
Safety wire hole
To prevent the camera from dropping accidentally, pass a
safety wire from the ceiling through these holes.
10
Terminal board cover
Protects the cable connection terminals against dirt, etc.
11
Control signal termination switch (TERM)
This is a termination ON/OFF switch for the input signals to the control signal terminal
2
. When it is set to ON, the
“RX+” to “RX–” route is terminated via 110 resistor.
12
Hook for attaching the drop prevention wire
Attach the drop prevention wire
4
to this hook.
13
Camera connector (female)
Connects with the camera connector
6
on the ceiling
mount.
14
Camera clamp
Fix the camera body to the ceiling mount by fastening the lock screw
7
to this clamp.
15
Camera body cover
Remove this cover when using the setting switches 16.
16
Setting switches
Set the PROTOCOL, etc. Ref. “Switch settings” on page 6.
17
Camera positioning alignment mark
When mounting the camera onto the ceiling mount ,align it with the mark
8
.
18
Ventilation
This is the ventilator for the internal cooling fan.
23 1
9
(Front)
(Back: Camera side)
4
5
6
5
7
8
10
Make sure that nothing interferes with the v entilator when installing the camera.
CAUTION
Page 5
5
1.
Make a hole (90 mm dia.) in the ceiling for passing through the connection cables.
2.
Connect the cables to the terminal board. Turn the power of all the connected equipment to OFF before connecting the cables. Remove the terminal board cover and connect the video signal cable (coaxial cable),the control signal cables (× 4) and the AC 24 V power cables (× 2).
AC 24 V power cables
Connect the AC 24 V power supply to the AC 24V terminals on the terminal board. To prevent connection errors or a cable dis­connection, we recommend the use of lug plates for the connec­tions. The following table sho ws the connection distances and connec­tion cables provided that 2-conductor VVF cables (vin yl-insulated vinyl sheath cables) are used.
Installation
Control signal cables
These cables should be connected only when it is required to control the camera using the RS-422A or RS-485 signals. The use of 0.65 4-conductor twisted pair cables is recommended. With these cables, the maximum extension distance is 1,200 m.
Video signal cables
Connect the coaxial cables to the video signal output terminals. Treat the tips of the coaxial cables as shown on the left before connection.
After having connected all of the required cables, again attach the terminal board cover.
3.
Attach the ceiling mount to the ceiling. Attach the ceiling mount to the ceiling using 4 screws, while pay­ing attention not to foul the connection cables. Use M4 or No. 8-32 UNC screws and bolts f or attaching the mount. If using wood screws, use those with a diameter of 4.1 mm. The screw head height should be no more than 4 mm.
• If thin cables are used(i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption (pan, tilt, zoom operated simultaneously). Either use a thick cable to restrict the voltage drop at the camera side to below 10%, or place the AC 24V power supply near to the camer a. If voltage drop occurs during operation, the performance will be unstable.
• Attach the cable conductors so that they do not come into con­tact with the drop prevention wire.
• Be sure to connect the AC 24 V cables correctly. Otherwise the camera will be damaged.
CAUTION
The ceiling to mount the TK-C675B has to be strong enough to support ten times the weight of this product. If the ceiling is not strong enough, make sure to apply reinforce­ment to the ceiling before installation.
To prevent accidental dropping of the camera, connect the ceiling plate or channel with the ceiling mount using a safety wire. Thread the safety wire through the safety wire hole on the ceiling mount.
CAUTION
ø90mm
1.
VIDEO OUT
TX– RX–
TX+ RX+
Drop prevention wire rail
2.
Remove the terminal board cover by flipping it up while pushing its top to the left.
(TX–)(TX+)
(RX–)
(RX+)
6mm
12mm
To AC24V
RX+ RX–
To monitor, etc.
TX+
To controller
To controller
Meshed wire
TX–
Polyethylene
Fold the meshed wire back.
Lug plates
Core conductor
3.
Screws
Ceiling mount
max. 4 mm
In order to reduce the generation of unnecessary sig­nals, be sure to install the provided ferrite cores when connecting the cables.
CAUTION
Maximum extension
100 m 260 m 410 m 500 m
Conductor diameter
1.0ømm
and more than
1.6ømm
and more than
2.0ømm
and more than
2.6ømm
and more than
(reference)
Page 6
6
Installation (continued)
4.
Turn the camera body cover to anti clockwise to set the word “RELEASE” on the camera body cov er ov er the mark, then pull the camera body cover upward. Transportation bracket is mounted when it is shipped from the factory. Make sure to remove it bef ore installation.
<How to remove the transportation bracket>
1
Remove the screw to remo v e the tr ansportation brack et.
2
Then fasten the dome cover with the scre w which was removed.
MANUAL SW3
Displayed OFF
Not displayed ON
(Initial set: OFF)
SW4PROTOCOL (1)
Point to point OFF Multi drop (when using the RM-P2580)
ON
(Initial set: OFF)
PROTOCOL (2)
SW5
Duplex (when using the RM-P2580)
OFF
Simplex ON
(Initial set: OFF)
SYNC SW6
INT OFF
LL ON
(Initial set: OFF)
LL mode U type: 60 Hz area only E type: 50 Hz area only
LOCK
RELEASE
LOCK
RELEASE
LOCK
RELEASE
Camera body cover
Camera body cover
Mark
Setting switches
Board
4.
ON
123456
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
SW1
Reserved
This switch must be set OFF.
DOUBLE
FIGURES
SINGLE
FIGURES
DISP
Machine ID
SW2
SW3
SW4
SW5
SW6
PROTOCOL (1)
PROTOCOL (2)
SYNC
5.
Transportation bracket
TERM switch
5.
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
(Initial set: 00)
ON OFF
RX TERM
(110 Ω)
SC46125-002
(Initial set: ON)
Ref. “Control signal connection” is on page 9.
TERM switch
• When SW4 is set to ON in order to connect more than one camera in series, set the TERM switch of only the terminal camera to ON. The TERM switch­es of the other cameras should be set to OFF. See “Connections” on page 8.
• When SW4 is set to OFF, this switch should be set to ON.
Machine ID
The machine ID should be set when us­ing the camera in Multi drop. Choose an ID in the 1 to 32 range.
SYNC (SW6)
When this switch is set to ON, the vertical sync of the camera is locked to the AC power line frequency.
• SW1 and SW2 are not in use for the present. Make sure that they are set to OFF.
PROTOCOL (2) (SW5)
Set according to the communication protocol used for control­ling the cameras.
When set to Multi drop, be sure to set the Machine ID of each camera.
PROTOCOL (1) (SW4)
Selects whether a single or multiple cameras are controlled in the system. Set PROT OCOL(1) to Multi drop when connecting multiple cam­eras in series.
If the power is supplied without removing the transportation bracket, initialization won’t be carried out properly , so that the camera cannot be controlled with a remote control unit. Make sure that it is removed.
CAUTION
5.
Check the switch settings and the communication protocol. Read the controller specifications carefully before proceeding to the switch settings.
Switch settings
DISP, PROT OCOL (1), (2), SYNC, Machine ID . Set these switch­es as required.
DISP (SW3)
Selects whether “MANUAL” is displayed or not when the cam­era's preset position is changed by the manual operation of the remote control unit.
The setting of these switches will be read only once at the time when the power is turned on. Even if the setting is changed in a state where the power is on, such a change will not be reflected.
CAUTION
Page 7
7
6.
Attach the camera body cover.
Align "RELEASE on the camera body cover with the indi­cation mark on the camera body , fit the cover onto the cam­era body, then rotate the cover clockwise until “LOCK” is indicated.
• Check that the three claws on the cover are locked onto the camera body and that there is no clearance between the cover and the camera body.
7.
Attaching the drop prevention wire.
As shown in the illustration, pull out the drop prevention wire from the ceiling mount and engage it with the drop prevention wire hook on the back of the camera.
Installation (continued)
Be sure to connect the drop prevention wire . Otherwise the camera body may drop from the ceiling.
CAUTION
8.
Mount the camera body.
1) Ensure that the lock screw on the ceiling mount is loose.
2) Align the camera position alignment mark (^) on the ceil­ing mount with the camera position alignment mark (
5
) on
the camera body and fit the camera body into the mount.
3) Rotate the camera body clockwise until it is checked. Then, check that the camera body clamp is located on the lock screw on the ceiling mount.
4) Tighten the lock screw.
Be sure to tighten the lock screw fully. Otherwise the cam­era body may vibrate or drop from the ceiling.
CAUTION
For dismounting the camera from the ceiling, perf orm steps
1.
to 8. in the reverse order.
LOCK
RELEASE
LOCK
RELEASE
Cover
Camera body cover
Setting switches
Claw
Claw
6.
Indication mark
LOCK
RELEASE
LOCK
RELEASE
7.
Ceiling mount on the ceiling
Drop prevention wire
Pull out.
Hook for attaching the Drop prevention wire
8.
Ceiling mount on the ceiling
Camera position alignment mark
Camera position alignment mark
Lock screw
Camera body Rotate the camera
body clockwise.
Tighten the lock screw.
Lock screw
Camera clamp
Page 8
8
Connections
When the system is composed of a single camera
When the system is composed of more than one camera
Controller*
Monitor
VIDEO OUT
CONTROL
PROTOCOL(1) SW4 :OFF TERM : ON
24V AC
VIDEO SWITCHER, etc.
CONTROLLER*
length of stub
length of stub
CONTROL Cable
CAM1 CAM2 CAM31 CAM32
PROTOCOL(1) : ON MACHINE ID : 01 TERM : ON
PROTOCOL(1) : ON MACHINE ID : 02 TERM : OFF
PROTOCOL(1) : ON MACHINE ID : 31 TERM : OFF
PROTOCOL(1) : ON MACHINE ID : 32 TERM : ON
length of stub
VIDEO SWITCHER, etc.
CONTROLLER*
length of stub
CONTROL Cable
PROTOCOL(1) : ON MACHINE ID : 01 TERM : ON
PROTOCOL(1) : ON MACHINE ID : 02 TERM : OFF
PROTOCOL(1) : ON MACHINE ID : 32 TERM : OFF
length of stub
CAM1 CAM2 CAM32
Terminate it with 110ohm.
If this camera and the cables connected to this camera is used where there are strong electromagnetic wa ves or where there is magnetism present, for example near a radio or TV transmitter, power transformer or an electric motor, the picture may produce noise and the colors may be affected. Optional controller is required to use the TK-C675B camera. Please contact your local dealer or installer for more information about this controller.
CAUTION
Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting to non-terminated equipment (camera or controller) must be as short as possible. If the length of stub is long, control may not be made correctly.
CAUTION
• Set the TERM switches of the cameras at both ends (CAM1 and CAM32) to ON, and TERM switches of the other cameras to OFF.
• Do not terminate at the controller.
• Set the TERM switch of CAM1 to ON, and also, terminate at the controller with 110 ohm. Set the TERM switches of the other cameras to OFF.
When the controller is located at the end.
When the controller is not located at the end.
Page 9
9
Connections (continued)
control signal connection
Use a twisted-pair cable for the connection.
Duplex
When the camera is controlled with the full duplex proto­col, set SW5 to OFF.
Simplex
When the camera is controlled with the simplex transmis­sion protocol, set SW5 to ON.
Camera Controller
RX+
RX–
TX+
TX–
TX+
TX–
RX+
RX–
Camera Controller
RX+
RX–
TX+
TX–
Two wires must be connected.
AC 24V
AC 24V INPUT terminals
Large ferrite core
Small ferrite core
Large ferrite core
TERMINAL BOARD
Control signal terminals
VIDEO OUTPUT terminals
Controller
Monitor, etc.
How to use the ferrite core
In order to reduce the generation of unnecessary signals, be sure to install the provided ferrite cores when connecting the cables.
Install the ferrite cores within 100 mm of the camera-side connectors. (Fasten the ferrite core with the provided wire clamp as the drawing on the right.)
• For AC 24V INPUT terminals Pass the AC 24V cable through the ferrite core twice and cconnect it to the camera.
• For Control signal terminals Pass the Control signal cable through the ferrite core three times and cconnect it to the camera.
• For VIDEO OUTPUT terminals Pass the VIDEO SIGNAL cable through the ferrite core and cconnect it to the camera.
Notes
Wire clamp
Four wires must be connected.
For example (connection with the RM-P2580)
Camera RM-P2580
RX+ C
RX– D
C TX+
D TX–
TX+ A
TX– B
A RX+
B RX–
Page 10
10
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENUMENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPENOPEN
FAR
TELE CLEAR
/HOME/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTO
PAN
OPTIONOPTION
1
OPTIONOPTION
2
CAMERACAMERA
POSI-POSI- TIONTION
AUTO
PATROLPATROL
CLOSECLOSE
NEAR
WIDEWIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERACAMERA POSITIONPOSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWERPOWER
KEY LOCKKEY LOCK
Menu settings
Menu operations
It is possible to set the menu screen of the remote control unit (RM-P2580).
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV
VIDEO A JD
.TEXT ED .TI ET. .AUTO PA SN LSET..AUTO PA ORT TTINGS. .FACT ROY ES
127 UP—L OFF OFF OFF
V.PH SAE
DE SELECTCAME ARMO
LOC.
POS. ETXT AUTO FL PI
EEDVAR. APN PS
AREA T I ELT
SIZE NORMALALM. TE TX
130 UP L OFF OFF OFF
V .PH SAE
DE SELECTCAME ARMO
LOC.
POS. ETXT AUTO FL PI
EEDVAR. APN PS
AREA T I ELT
SIZE NORMALALM. TE TX
Item Cursor
Submenu to be followed
SETUP screen (main menu)
SETUP screen of the camera
Sample screen display
Change
mark
Sample screen after change
1.
Turn the rear power switch of the RM-P2580 to ON.
2.
Pressing the MENU button for approximately 3 seconds will light the LED and the SETUP screen will be outputted from the rear MONITOR OUTPUT-1.
3.
Use the pan/tilt control lever to move the cursor (>) and select CAMERA.
• The cursor will move up when the lever is pressed up (6).
• The cursor will move down when the lever is pressed down (7).
4.
Press the SET button to display the SETUP screen of the camera.
MEMO
Submenu is to follow for items with · · .
5.
Select the item in the same manner as step 3.
6.
Change the value of the selected item by moving the pan/ tilt control elver right and left.
• The value will become smaller when the lever is pressed to the left (8).
• The value will become larger when the lever is pressed to the right (t).
The change mark ( ) shown in the diagram on the left will appear when changes have been made.
MEMO
For details concerning submenu settings, see the next page.
7.
When changes have been made, press the MENU b utton to return to the normal screen.
This chapter shows an example of connection to the JVC’s remote control unit RM-P2580. Read it and refer also to the instruction manual of the RM-P2580.
Page 11
11
The menu screen flow is as follows. For details, see the reference pages.
Menu screen flow
Menu settings (continued)
Z Page 12
Normal screen
127 UP—L OFF OFF OFF
V.PH SAE
DE SELECTCAME ARMO
LOC.
POS. ETXT AUTO FL PI
EEDVAR. APN PS
AREA T I ELT
SIZE NORMALALM. TE TX
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV VIDEO A JD
.TEXT ED .TI
ET. .AUTO PA SN
LSET..AUTO PA ORT TTINGS. .FACT ROY ES
12dB 1/60 HHIG 8/2 5
AGC OMDE
DEO AD JUSTCAME ARVI PEEDS
SHUT ETR ENHA CNE AV/ P AEK COLOR LLEVE
TEXT . .
AUTO OFF ATW 127
POSI ITON
ST FOR PO ISIDEO ADJVU
E
IRIS MOD BLC OMDE W.BA ALNEC RB G IAN
XT . .
.
CAME ARTE
TEDITTEX T..X
ALARM TE AREA TE .TX
MODE
ITION
RETURN
NSET..
SET . .
AUTO PAN
PAN SETUATO
ITIOS
STAR T PO RETU NRSOP
HOME 3 0 SECPAT ORL1 POS1 3 0 SECPAT ORL2 POS2 3 0 SECPAT ORL3 POS3 3 0 SECPAT ORL4 POS4 3 0 SECPAT ORL5 POS5 3 0 SECPAT ORL6 POS6 3 0 SECPAT ORL7 POS7 3 0 SECPAT ORL8
M MODE FOCUS/BWFWD D Z O O
TROL MO E1DAU OTPA
ETT INGS YESFACT ROYS
SETTINGSFA TCORY
Z Page 13
Z Page 14
Z Page 15
Z Page 19
Z Page 20
Z Page 21
Camera SETUP screen
CAMERA MODE SELECT screen
CAMERA VIDEO ADJUST screen
VIDEO ADJUST FOR POSITION screen
TEXT EDIT screen
AUTO PAN SET screen
AUTO PATROL SETUP screen
FACTORY SETTINGS screen
Page 12
12
Menu settings (continued)
CAMERA MODE SELECT screen
Item
V.PHASE
POSITION TEXT LOCA TION
AUTO FLIP
VAR.PAN SPEED
AREA TITLE
ALM.TEXT SIZE
Factory
setting
127
UP–L
OFF
OFF
OFF
DOUBLE
Variable
range
0 ~ 255
UP–L, DOWN–L UP–C, DOWN–C UP–R, COWN–R
OFF ON
OFF ON
OFF ON
NORMAL DOUBLE
Function
Set when adjusting the vertical of other cameras operating in the line lock (LL) mode. Adjust while viewing the screen. The value will become smaller when the pan/tilt lev er is pressed to the left (8). The value will become larger when the pan/tilt lever is pressed to the right (t).
Used to set the display position of position titles. UP: positions the title at the top of the screen. DOWN: positions the title at the bottom of the screen. L: positions the title towards the left of the screen. C: positions the title in the center of the screen. R: positions the title towards the rigt of the screen.
The camera is flipped over automatically by 180 degree at the tilting limit. (This makes it possible for the camer a to continue tilted straight down ward.) ON: Auto flip will funtion OFF: Auto flip will not funtion
The panning speed is varied automatically according to the zoom ratio of the lens. (The panning speed decreases when the zoom lens is set near TELE and increases when it is set near WIDE). ON: Var. pan speed will function OFF: Var. pan speed will not function
The Area Title function divides the space covered by a camera into sixteen units, with a 16-character ID allocated to each unit. (AREA 1 ~ AREA16) The set AREA TITLE is displayed when manually panning the camera. ON: Area title is displayed OFF: Area title is not displayed
The character size to display during ALARM is set.
AREA
16
AREA
1
AREA
2
AREA
3
ALARM
ALARM
NORMAL SIZE DOUBLE SIZE
Page 13
13
CAMERA VIDEO ADJUST screen
Menu settings (continued)
Item
AGC MODE
SHUTTER SPEED
ENHANCE
AV/PEAK
COLOR LEVEL
Factory
setting
12 dB
1/60 (1/50)
HIGH
8/2
5
Variable
range
OFF 12 dB 20 dB
1/60 (1/50), 1/100 (1/60), 1/1000, 1/2000, 1/4000, 1/10000 ( ) is version E.
LOW HIGH
10/0 9/1 8/2 7/3 6/4 5/5
0 ~ 10 (increments of 1)
Function
The maximum gain of the AGC (Automatic gain control) is set. This setting value becomes a maximum limit when the gain is automatically changed according to brightness. Set this to 20dB when there is little light on the subject.
MEMO
The gain is automatically raised in dark areas when the AGC is in operation. At this time, the screen may appear rough; however, this is not a malfunction.
Set the electronic shutter speed for each camera. To reduce flickering of fluorescent lighting, set the electronic shutter is speed to 1/100 (1/50) when in areas with commercial power supply frequency of 50Hz, and 1/60 when in areas of 60Hz, set to 1/60.
MEMO
More of the smearing effect, which is characteristic of CCD , will be noticed when the shutter speed is increased.
This function compensates the edge to enhance the sharpness of the monitor screen and can be set per camera. LOW: low edge enhancement HIGH: high edge enhancement
This setting is effective only during auto iris. For the exposure detection, the ratio of the average value (AV) and the peak value (PK) is set for each camera. Increase the AV (ex. 10/0):
Increase the AV when portions other than the highlighted ar­eas of the screen is dark. Conv enient when there is lighting in a dark room.
Increase the PK (ex. 5/5):
Increased when there is halation on the highlighted areas of the screen.
Used when setting the color level of the image signal. The screen colors will become lighter when small value is set. The colors will become darker when large value is set.
Page 14
14
OFF AREA 1 AREA 2 AREA 3 AREA 4
Menu settings (continued)
VIDEO ADJUST FOR POSITION screen
Item
POSITION TEXT
IRIS MODE
BLC MODE
W. BALANCE
RB GAIN
Factory
setting
AUTO
OFF
ATW
127
Variable
range
AUTO AUTO+ AUTO– MANUAL
OFF AREA1 AREA2 AREA3 AREA4
ATW MANUAL
0 ~ 255 (increments of 1)
Function
It is possible to set up to 16 characters to use as titles for set positions (max. 63) and home positions (max. 1). See the next page for details on settings
MEMO
Always register positions before setting titles. Positions cannot be selected unless they have been registered. For details on registering positions, see the instruction manu­al of the used remote control.
Set the iris depending on the brightness. AUTO: the iris is automatically adjusted to the normal value. AUT O+: the iris is automatically adjusted brighter than the nor-
mal value
AUTO–: the ir is is automatically adjusted darker than the nor-
mal value.
MANU: used when settings the iris manually
With this setting, light measurement areas are selected during auto iris control. Set when there is light in the background of the subject. There are 4 types of settings. Choose depending on the loca­tion of the light source.
The white balance is adjusted manually or automatically for light within the range of 2000°k and 7000°k. ATW: automatic light temperature adjustment mode MANU: manual adjustment mode (Adjustment is made in the next item, RB GAIN)
Used when adjusting the white balance manually. Small value: blue is enhanced Large value: red is enhanced
MEMO
Value cannot be changed when W. BALANCE is set to ATW.
Light
measurement
area
Light measurement
area
Light measurement
area
Light measurement
area
Light measurement
area
Page 15
15
1.
Select the camera using the remote control (See the in­struction manual of the used remote control) The image signal of the home position of the selected cam­era will be outputted. Press the MENU button to display the SETUP screen of the remote control, select CAMERA, then press the SET button to display the CAMERA SETUP screen.
2.
Select POSITION TEXT item in the VIDEO ADJUST FOR POSI screens, then press the SET button to display the POSITION TEXT screen (see left).
3.
To set a home position title, skip to 4. To set a position title, select the position to title from the remote control unit. The camera will move to the selected position.
4.
In the POSITION TEXT screen, the first characters of the character area and the title input area will flash, allowing input.
5.
Use the 6, 7, 8 and t of the pan/tilt control lever to select the character.
6.
When the first character of the title as been selected, press the ZOOM (TELE) button to move on to the next charac­ter. At this time, the first character will be confirmed. Pressing the ZOOM (WIDE) button will move the flashing position in the title input area to the left. Use when correct­ing errors to the set title.
7.
To set the next position title, repeat steps 3 through 6. DAT A SA VED will appear for appro ximately 3 seconds when selecting the next position.
8.
To set other position title of a camera, repeat steps
1
through 7.
9.
When all positions have been set, press the MENU button to return to the normal screen.
POSITION TEXT screen
Menu settings (continued)
It is possible to set titles to positions (max. 63) and home positions (max. 1) using text of 16 characters or less.
MEMO
Always register positions before setting titles. Positions cannot be selected when they are not registered. To register positions, see the instruction manual of the used remote control unit.
POSITION TEXT screen
(U version)
POSITION TEXT screen
(E version)
When selecting the next position
9ABCDEFGHIJK0123 54678
VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq
/–:
TEXT ZOOMSE ELCT
NTEXTPO ISTIO
SPACE Character section (blink)
Title input section (blink)
9ABCDEFGHIJK0123 54678 VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq ЫЗСдлпцьвкоф/–: ÄÖ ÂÜÊÎÔ ùçñß¡¿éíыб у аъимт
TEXT ZOOMSE ELCT
NTEXTPO ISTIO
9ABCDEFGHIJK0123 54678 VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq ЫЗСдлпцьвкоф/–: ÄÖ ÂÜÊÎÔ ùçñß¡¿éíыб у аъимт
VEDDA ATSA
NTEXTPO ISTIO
Page 16
16
1.
Select the camera to set the camera title (See the instruc­tion manual of the used remote control). The image signal of the selected camera will be outputted when pressing CAMERA Numeric Key → ENTER button.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select CAMERA, then press the SET button to display the SETUP screen of the camera. At this time, the camera will move to the home position.
3.
Use the pan/tilt control lever to select TEXT EDT , then press the SET button to display the TEXT EDUT screen.
4.
Select CAMERA TEXT, then press the SET button to dis­play the CAMERA TEXT screen.
5.
In the CAMERA TEXT screen, the first characters of the character area and the title area will flash, allowing input.
6.
Use the 6, 7, 8 and t of the pan/tilt control lever to select the character.
7.
When the first character of the title as been selected, press the ZOOM (TELE) button to confirm the first character and to move on to the next character of the title. Pressing the ZOOM (WIDE) button will move the flashing position in the title input area to the left. Use when correct­ing errors to the set title.
To set the next camera title, repeat steps
1
through 7.
8.
When all camera title have been set, press the MENU b ut­ton to return to the normal screen.
Menu settings (continued)
CAMERA TEXT screen
It is possible to set up to 16 characters to use as a title during camera selection.
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI- TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWERPOWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
button
ZOOM(WIDE)
button
ZOOM(TELE)
buttons
Numeric Key
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV VIDEO A JD
.TEXT ED .TI ET. .AUTO PA SN LSET..AUTO PA ORT TTINGS. .FACT ROY ES
XT . .
.
CAME ARTE
TEDITTEX T..X
ALARM TE AREA TE .TX
9ABCDEFGHIJK0123 54678 VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq ЫЗСдлпцьвкоф/–: ÄÖ ÂÜÊÎÔ ùçñß¡¿éíыб у аъимт
TEXT ZOOMSE ELCT
ATEXTACMER
Displayed only for E version.
CAMERA TEXT screen
TEXT EDIT screen
Camera SETUP screen
Remote control SETUP screen
Page 17
17
1.
Select the camera to set the area title (See the instruction manual of the used remote control). The image signal of the selected camera will be outputted when pressing CAMERA Numeric Key → ENTER button.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select CAMERA, then press the SET button to display the SETUP screen of the camera. At this time, the camera will move to the home position.
3.
Use the pan/tilt control lever to select TEXT EDIT, then press the SET button to display the TEXT EDIT screen.
4.
Select AREA TEXT, then press the SET button to display the AREA TEXT 1 screen. This corresponds to home position area 1.
5.
In the AREA TITLE 1 screen, the first characters of the character area and the title area will flash, allowing input.
6.
Use the 6, 7, 8 and t of the pan/tilt control lever to select the character.
7.
When the first character of the title as been selected, press the ZOOM (TELE) button to confirm the first character and to move on to the next character of the title. Pressing the ZOOM (WIDE) button will move the flashing position in the title input area to the left. Use when correct­ing errors to the set title.
8.
To set the next area title, press the FOCUS (FAR) button. The camera will move to the ne xt area and the AREA TEXT 2 screen will appear. In the same manner as AREA TEXT 1, repeat steps
5
through 7 to set the title.
9.
When all area title have been set, press the MENU button to return to the normal screen.
AREA TEXT screen
Menu settings (continued)
FOCUS(NEAR)
FOCUS(FAR) button
button
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENUMENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO
PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI-
TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDEWIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERACAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARMALARM
POWERPOWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
button
ZOOM(WIDE)
button
ZOOM(TELE)
buttons
Numeric Key
The 360° panning angle (horizontal rotation) is divided into 16 sectors, allowing you to check the title in each area. When the camera is manually panned, the preset area designation is shown on the screen. It is possible to set titles of 16 characters or less to each area. To select whether to display the title or not is made in AREA TITLE.
AREA
16
AREA
1
AREA
2
AREA
3
XT . .
.
CAME ARTE
TEDITTEX T..X
ALARM TE AREA TE .TX
9ABCDEFGHIJK0123 54678 VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq ЫЗСдлпцьвкоф/–: ÄÖ ÂÜÊÎÔ ùçñß¡¿éíыб у аъимт
AREA FOCUSEXTTZOOM
TEXT 10RAEA
Displayed only for E version.
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV
VIDEO A JD
.TEXT ED .TI
ET. .AUTO PA SN
LSET..AUTO PA ORT
TTINGS. .FACT ROY ES
Camera SETUP screen
Remote control SETUP screen
AREA TEXT screen
TEXT EDIT screen
Page 18
18
1.
Select the camera to set the alarm title (See the instruc­tion manual of the used remote control). The image signal of the selected camera will be outputted when pressing CAMERA Numeric Key → ENTER button.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select CAMERA, then press the SET button to display the SETUP screen of the camera. At this time, the camera will move to the home position.
3.
Use the pan/tilt control lever to select TEXT EDIT, then press the SET button to display the TEXT EDIT screen.
4.
Select ALARM TEXT, then press the SET button to display the ALARM TEXT 1 screen.
5.
In the ALARM TITLE 1 screen, the first characters of the character area and the title area will flash, allowing input.
6.
Use the 6, 7, 8 and t of the pan/tilt control lever to select the character.
7.
When the first character of the title as been selected, press the ZOOM (TELE) button to confirm the first character and to move on to the next character of the title. Pressing the ZOOM (WIDE) button will move the flashing position in the title input area to the left. Use when correct­ing errors to the set title.
8.
T o set the ne xt alarm title, press the FOCUS (F AR) b utton. The ALARM TEXT 2 screen will appear . In the same man­ner as ALARM TEXT 1, repeat steps
5
through 7 to set
the title.
9.
When all alarm title have been set, press the MENU but­ton to return to the normal screen.
Menu settings (continued)
ALARM TEXT screen
It is possible to set up to 12 characters to use as a title during alarm.
FOCUS(NEAR)
FOCUS(FAR) button
button
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO
PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI- TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
button
ZOOM(WIDE)
button
ZOOM(TELE)
buttons
Numeric Key
XT . .
.
CAME ARTE
TEDITTEX T..X
ALARM TE AREA TE .TX
9ABCDEFGHIJK0123 54678 VWXYZabcdefgNMLOPRQSTU
rs tuvwxyz. ,'jkhi l nmopq ЫЗСдлпцьвкоф/–: ÄÖ ÂÜÊÎÔ ùçñß¡¿éíыб у аъимт
A L ARM F OCUSETXTZOOM
TEXT 1AALRM
Displayed only for E version.
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV
VIDEO A JD
.TEXT ED .TI
ET. .AUTO PA SN
LSET..AUTO PA ORT
TTINGS. .FACT ROY ES
Camera SETUP screen
Remote control SETUP screen
TEXT EDIT screen
ALARM TEXT screen
Page 19
19
AUTO PAN SET screen
Menu settings (continued)
FOCUS button
ZOOM button
IRIS button
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO
PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI- TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWERPOWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
buttons
Numeric Key
Auto pan is a feature which allows the camera to slowly move sideways automatically and is set per each camera. There are 3 AUTO PAN modes: RETURN that goes back and forth between two points, RIGHT that makes a right rotation and LEFT that makes a left rotation.
Picture at the
start position
Picture at the stop position
Slow speed
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV
VIDEO A JD
.TEXT ED .TI
ET. .AUTO PA SN
LSET..AUTO PA ORT
TTINGS. .FACT ROY ES
MODE
ITION
RETURN
NSET..
SET . .
AUTO PAN
PAN SETUATO
ITIOS
STAR T PO
RETU NRSOP
SITION SETSTA TRPO
SITION SETRETU NRPO
1.
Select the camera to set (See the instruction manual of the used remote control). Press CAMERA Numeric Key ENTER button to output the im­age signal to the selected camera.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select CAMERA, then press the SET button to display the SETUP screen of the camera. At this time, the camera will move to the home position.
3.
Use the pan/tilt control lever to AUTO PAN SET, then press the SET button to display the AUTO PAN SET screen.
4.
In the AUTO PAN SET screen, select AUTO PAN MODE. Select the auto pan mode from RETURN, RIGHT and LEFT using the pan/tilt control lever.
5.
Next, select START POSITION SET, then press the SET button to display the START POSITION SET screen. Adjust the angle of view at the start position using the pan/tilt control lever, IRIS, focus and zoom button.
6.
Pressing the MENU button will display the AUTO PAN SET screen and the set angle of view at the start position will be registered. At this time, DATA SAVED will appear on the screen.
When selecting the mode to RETURN, set RETURN POSITION SET .
7.
Select RETURN POSITION SET, then press the SET button to dis­play the RETURN POSITION SET screen. Adjust the angle of view at the stop position, then press the MENU but­ton. DATA SAVED will appear and the stop position will be registered.
MEMO
• Shifting in the direction of the tilt and lens operations cannot be made at the stop position. To mak e field of view changes and lens operations, press the SET button and set the stop position after setting the field of view and making lens operations in the START POSITION SETUP screen.
• Correct data will not be written when pressing the MENU button or SET button while the camera is in motion. Always check to make sure that the camera is still before pressing the MENU or SET button.
8.
When the start and stop positions have been set, press the MENU button to return to the normal screen.
Remote control SETUP screen
Camera SETUP screen
START POSITION SET screen
RETURN POSITION SET screen
Example:
Action of Retun mode
Page 20
20
1.
Select the camera to set for auto patrol (See the instruc­tion manual of the used remote control) Press CAMERA Numeric Key ENTER button to out­put the image of the selected camera.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select the camera, then press the SET button to display the SETUP screen of the camera. At this time, the camera will move to the home position.
3.
Select AUTO PATROL SET using the the pan/tilt control lever, then press te SET button to display the AUTO PA­TROL MODE 1 screen.
4.
Use the pan/tilt control lever to set the auto patrol posi­tions and time. The time can be selected from 30 sec., 45 sec., 1 min., 2 min., 3 min., 6 min. and SKIP.
If the selection of auto patrol position is not necessary , set to SKIP. The factory setting for auto patrol will move the cam­era from HOME to POS63 at 30 seconds.
5.
The setting of the next mode is made using the FOCUS (FAR) and FOCUS (NEAR) button.
6.
When all settings have been made, press the MENU but­ton. At this time, DATA SAVED will appear on the screen.
Menu settings (continued)
AUTO PATROL SETUP screen
The auto patrol is a feature to move the camer a to m ultiple positions at high speed in a set sequence and time and is set per each camera.
FOCUS button
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO
PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI-
TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
buttons
Numeric Key
High speed
High speed
High speedHigh speed
POSITION
POSITION
POSITION
POSITION
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
Remote control SETUP screen
Camera SETUP screen
AUTO PATROL MODE 1 screen
HOME 3 0 SECPAT ORL1 POS1 3 0 SECPAT ORL2 POS2 3 0 SECPAT ORL3 POS3 3 0 SECPAT ORL4 POS4 3 0 SECPAT ORL5 POS5 3 0 SECPAT ORL6 POS6 3 0 SECPAT ORL7 POS7 3 0 SECPAT ORL8
M MODE FOCUS/BWFWD D Z O O
TROL MO E1DAU OTPA
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV VIDEO A JD
.TEXT ED .TI ET. .AUTO PA SN LSET..AUTO PA ORT TTINGS. .FACT ROY ES
Page 21
21
FACTORY SETTINGS screen
Menu settings (continued)
It is possible to return all camera settings to the factory settings.
buttonbutton
PAN/TILT
SETMENU
control lever
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8 0
5
2
9
6
3
ENTER
AUTOAUTO
PANPAN
OPTION
1
OPTION
2
CAMERACAMERA
POSI- TION
AUTOAUTO
PATROLPATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTE CONTROL UNIT REMOTE CONTROL UNIT
RM-P2580
ALARM
POWERPOWER
KEY LOCKKEY LOCK
button
CAMERA
button
ENTER
buttons
Numeric Key
SETUP
DE S
FOR
ELECT. . ADJUST . .
POS I . .
CAME ARMO
DEOI
CAME ARV VIDEO A JD
.TEXT ED .TI ET. .AUTO PA SN LSET..AUTO PA ORT TTINGS. .FACT ROY ES
ETT INGS YESFACT ROYS
SETTINGSFA TCORY
SETUP
SETU
NIT..
P..POSI ITON CAME AR.. CONT ORL U
Remote control SETUP screen
Camera SETUP screen
FACTORY SETTINGS screen
1.
Select the camera to initialize settings (See the instruction manual of the used remote control). Press CAMERA Numeric Key ENTER button to out­put the image signal of the selected camera.
2.
Press the MENU button to display the SETUP screen of the remote control. Use the pan/tilt control lever to select CAMERA, then press the SET button to display the SET­UP screen of the camera. At this time, the camera will move to the home position.
3.
Use the pan/tilt control lever to select FACTORY SET­TINGS, then press the SET button to display the FACTO­RY SETTINGS screen.
4.
Use 8 and t of the pan/tilt control lever to select the FACTORY SETTINGS item to YES.
5.
Pressing the SET button will initialize settings in approxi­mately 3 seconds and DATA SAVED will appear.
6.
Press the MENU button to return to the normal screen.
CAUTION
If this setting operation is performed, various settings memorized in the camera will all return to the state of fac­tory shipment.
Especially , all the preset positions will be cleared. There­fore, exercise utmost caution!
Page 22
22
Troubleshooting
Symptom
Video is not output.
Power cannot be turned on.
The camera moves from the preset position.
Power can be turned on, but it later turns off when the pan/tilt unit is operated.
The remote control unit does not function.
Operation is abnormally slow when controlling the unit with the RM-P2580.
Cause (Information)
• Is there a problem in the power cables con-nect­ing the camera to the power supply unit. (If the power cables are too long or are of the wrong size, the correct voltage ma y not be supplied due to an increase in resistance.)
• Are cables connected properly to the terminal board on the ceiling mount?
• Was the AC 24 V power supply switched ON and OFF repeatedly? (The protection circuit may be activated when the power is switched ON OFF ON within 5 sec.)
• Has the panning been rotated manually for clean­ing, etc., while the power was on? (The camera controls the panning position based on the initial operation at the time the power is turned on. If the camera position is changed man­ually after the initial operation. the preset camer a position is displaced.)
• Is there a problem with the power cables con-nect­ing the camera to the power supply unit. (If the power cables are too long or are of the wrong size, the voltage may drop due to an increase in resistance during the panning operation.)
• Is the cable connected correctly?
• Are the dip switches set correctly?
• Is the cable (particularly the line connecting to TX+ and TX– of the camera) correctly connected to the RM-P2580?
• The PROTOCOL (2) switch is set on the “Sim­plex” side b y mistake . Is it not? (Ref er to P age 6)
Remedy
• Connect low resistance cables.
• Place the AC 24V power supply near to the camera. (Check that the voltage supplied to the terminal board is as rated when the camera is operating, that is, when the rated current flows through it.)
• Connect cables properly.
• Once the AC 24 V po wer is switched OFF, it should be switched ON again only after a lapse of more than 5 seconds.
• Switch the camera power supply OFF then ON again.
• Change the power cables to ones of a lower re­sistance (i.e. thicker or shorter) cables.
• Place the AC 24V power supply near to the camera.
• Connect the cable correctly according to the in­structions given in Page 9.
• Set the dip switches correctly according to the in­structions given in Page 6, and turn the power on again.
• Connect the cable correctly according to the in­structions given in Page 9.
• Set the PROT OCOL (2) switch to the “Duple x” side.
Page 23
23
Specifications
External dimensions [Unit : mm]
CAMERA
Signal system : U type Based on NTSC standard
E type Based on PAL standard Image device : 1/3"IT CCD Effective picture:U type 380,000 pixels, 771 (H) × 492 (V)
element
E type
440,000 pixels, 753 (H) × 582 (V) Sync system : Line lock/Internal Video S/N : 48dB (Typ.) Horizontal : 470 TV lines (Typ.)
resolution Minimum : 3 lx (Typ . at F1.2)
illumination Camera ID : 16 letters White balance : ATW/Manual
LENS
Zoom ratio : ×16, f4.5 to f72mm Iris range : F1.2 to F170 (suitable) Zooming speed : Approx. 2 sec. (MAX) Focus speed : Approx. 1 sec. (MAX)
9
0
˚
(
T
I
L
T
)
ø154
87
ø152
1
ø152
ø143
ø143
29
85
116
185
ø88
Ceiling
113
113
Screw
positions
Screw positions
Mounting hole ø90
Ceiling mount hole
MOVING MECHANISM
Panning : 360 degree endless Tilting :0 to 90 degrees Panning speed : 240 degree/sec, 80 degree/sec,
60 degree/sec, 40 degree/sec, 20 degree/sec, 12 degree/sec, 6 degree/sec, 4 degree/sec, 2 degree/sec
Tilting speed :
120 degree/sec, 60 degree/sec, 40 degree/sec, 30 degree/sec, 20 degree/sec, 10 degree/sec, 6 degree/sec, 2 degree/sec, 1 degree/sec,
GENERAL
Remote control input :RS-422A or RS-485 (non-isolated)
terminal Power requirement : AC24V`, 50/60Hz Power consumption :U type Approx. 23W
E type Approx. 1.4A Operation temperature
:–10°C to 50°C
range
(recommendation : 0°C to 40°C) Dimensions :Approx. 154mm diameter × 185mm Mass :Approx. 2.0kg (with Ceiling mount) Accessories :INSTRUCTIONS × 1
Ferrite core × 3
Ceiling mount × 1
Page 24
TK-C675B COMBINATION CAMERA
VICTOR COMPANY OF JAPAN, LIMITED
Printed in Japan SC96898-001
© 1999 VICTOR COMPANY OF JAPAN, LIMITED
is a registered Trademark owned by VICTOR COMPANY OF JAPAN, LTD. is a registered Trademark in JAPAN, the U.S.A., the U.K. and many other countries.
Loading...