JVC DLA-HD2KE, DLA-HD2KU, SPX 7800BT Service Manual

Page 1
PA019200410
SERVICE MANUAL
HOME THEATER PROJECTOR
DLA-HD2KU, DLA-HD2KE
¨
ON
OFF
OPERATE
FOCUS
TEST
LIGHT
MENU EXIT
ENTER
PRESET
HIDE
2 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
3 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13
4 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18
5 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31
COPYRIGHT © 2004 Victor Company of Japan, Limited
TABLE OF CONTENTS
No.PA019
2004/10
Page 2
SPECIFICATION
GENERAL
Type Dimensions (W × H ×D)
Mass Power requirements
Power Consumption Operating temperature
Operating humidity Storage temperature
Projection angle (Adjustable Foot)
Remote control unit RM-MH2KG
operation
Accessories Remote control unit (RM-MH2K) × 1
OPTIC
Projection system D-ILA device
Projection lens 1.3times (1.8 : 1-2.35 : 1) manual ZOOM
Screen size 40" (101.6cm) [tele : min]-200" (508cm)
Projection distance approx 1.5m (4.92ft)-12m(39.36ft) Light lamp BHL5006-S
D-ILA HOME THEATER PROJECTOR Approx. 298 mm × 134 mm × 360 mm (Approx. 11-7/8" × 5-3/10" × 14-1/5")
(Excluding handle, lens and protrusions)
Approx. 6.2kg (Approx.13.7lbs) AC 100-240V 50Hz/60Hz
3.5A (100VAC)~1.4A (240VAC)
+5°~+35°[41°F~95°F] 20%~80% (no-condensation)
-10°C~+60°C[14°F~140°F] Vertical : max. +6° upper
Horizontal : max. 3° (±1.5°)
Distance : 7m Angle: Horizontal =±30° Vertical =±20°
Mass
100g (includes dry cell battery)
Dry cell battery (size : UM-4/AAA/R02) × 2 DVI Cable (5m) × 1 Power code (2.5m) × 1
D-ILA(reflective activematrix principle)system
0.82-inch(2.1cm) measured diagonally [H:1920 pixels × V:1080 pixels] × 3 < Total : 6,220,000 pixels >
lens [50% fix shift]
< recommended > *measured diagonally with aspect 16:9
UHP(Ultra High-Pressue mercury) lamp
ELECTRIC
Input signal 1080 / 60p signal, 1080 / 50p signal Resolution 1920 × 1080 dots Scanning frequency Horizontal : 56.25kHz,67.43kHz,67.5kHz
Vertical : 50Hz,59.94Hz,60Hz
Keystone distortion correction
Fuse QMF51D2-6R3-J1(6.3A)
OUTPUT TERMINAL
CONTROL SYNC OUT × 1
INPUT CONNECTORS
VIDEO IN
CONTROL Using external computer control
RS-232C RS-232C protocol
SERVICE stereo mini-jack × 1 (For Service)
Top-bottom tilt: Horizontal=about 25°, Vertical=about 5°
stereo mini-jack (For Service)
DVI DVI-D (single-24pin) terminal
HDCP-compatible
D-sub 9-pin × 1
1-2 (No.PA019)
Page 3
SECTION 1
r
e
PRECAUTION
1.1 SAFTY PRECAUTIONS
Prior to shipment from the factory, JVC products are strictly in­spected to conform with the recognized product safety and elec­trical codes of the countries in which they are to be sold.However,in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced.
1.1.1 Precautions during Servicing
(1) Locations requiring special caution are denoted by labels
and inscriptions on the cabinet, chassis and certain parts of the product.When performing service, be sure to read and comply with these and other cautionary notices appearing in the operation and service manuals.
(2) Parts identified by the symbol and shaded ( ) parts
are critical for safety. Replace only with specified part numbers.
NOTE :
Parts in this category also include those specified to comply with X-ray emission standards for products using cathode ray tubes and those specified for compliance with various regulations regarding spu­rious radiation emission.
(3) Fuse replacement caution notice.
Caution for continued protection against fire hazard. Replace only with same type and rated fuse(s) as speci­fied.
(4) Use specified internal wiring. Note especially:
• Wires covered with PVC tubing
• Double insulated wires
• High voltage leads
(5) Use specified insulating materials for hazardous live parts.
Note especially:
• Insulation Tape
• PVC tubing
•Spacers
• Insulation sheets for transistors
•Barrier
(6) When replacing AC primary side components (transformers,
power cords, noise blocking capacitors, etc.) wrap ends of wires securely about the terminals before soldering.
Consequently, when servicing these products, replace the cathode ray tubes and other parts with only the specified parts. Under no circumstances attempt to modify these cir­cuits.Unauthorized modification can increase the high volt­age value and cause X-ray emission from the cathode ray tube.
(12) Crimp type wire connectorIn such cases as when replacing
the power transformer in sets where the connections be­tween the power cord and power trans former primary lead wires are performed using crimp type connectors, if replac­ing the connectors is unavoidable, in order to prevent safe­ty hazards, perform carefully and precisely according to the following steps.
Connector part number :E03830-001
Required tool : Connector crimping tool of the proper type which will not damage insulated parts.
Replacement procedure
a) Remove the old connector by cutting the wires at a
point close to the connector.Important : Do not re­use a connector (discard it).
cut close to connector
Fig.1-1-3
b) Strip about 15 mm of the insulation from the ends
of the wires. If the wires are stranded, twist the strands to avoid frayed conductors.
15 mm
Fig.1-1-4
c) Align the lengths of the wires to be connected. In-
sert the wires fully into the connector.
Metal sleeve
Fig.1-1-1
(7) Observe that wires do not contact heat producing parts
(heatsinks, oxide metal film resistors, fusible resistors, etc.)
(8) Check that replaced wires do not contact sharp edged or
pointed parts.
(9) When a power cord has been replaced, check that 10-15
kg of force in any direction will not loosen it.
Power cord
Fig.1-1-2 (10) Also check areas surrounding repaired locations. (11) Products using cathode ray tubes (CRTs)In regard to such
products, the cathode ray tubes themselves, the high volt­age circuits, and related circuits are specified for compli­ance with recognized codes pertaining to X-ray emission.
Connector
Fig.1-1-5
d) As shown in Fig.1-1-6, use the crimping tool to crimp
the metal sleeve at the center position. Be sure to crimp fully to the complete closure of the tool.
1.2 5
2
.0
5.5
Crimping tool
Fig.1-1-6
e) Check the four points noted in Fig.1-1-7.
Not easily pulled free
Wire insulation recessed
more than 4 mm
Crimped at approx. cente
of metal sleev
Conductors extended
Fig.1-1-7
(No.PA019)1-3
Page 4
1.1.2 Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have been returned to original positions, Afterwards, perform the following tests and confirm the specified values in order to verify compli­ance with safety standards.
(1) Insulation resistance test
Confirm the specified insulation resistance or greater be­tween power cord plug prongs and externally exposed parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, ear­phone jacks, etc.).See table 1 below.
(2) Dielectric strength test
Confirm specified dielectric strength or greater between power cord plug prongs and exposed accessible parts of the set (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, earphone jacks, etc.). See Fig.1-1-11 below.
(3) Clearance distance
When replacing primary circuit components, confirm spec­ified clearance distance (d), (d') between soldered termi­nals, and between terminals and surrounding metallic parts. See Fig.1-1-11 below.
d
Chassis
d'
Power cord primary wire
Fig.1-1-8
(4) Leakage current test
Confirm specified or lower leakage current between earth ground/power cord plug prongs and externally exposed ac­cessible parts (RF terminals, antenna terminals, video and audio input and output terminals, microphone jacks, ear­phone jacks, etc.). Measuring Method : (Power ON)Insert load Z between earth ground/power cord plug prongs and externally ex­posed accessible parts. Use an AC voltmeter to measure across both terminals of load Z. See Fig.1-1-9 and follow­ing Fig.1-1-12.
ab
Externally exposed accessible part
Z
V
c
A
Fig.1-1-9
(5) Grounding (Class 1 model only)
Confirm specified or lower grounding impedance between earth pin in AC inlet and externally exposed accessible parts (Video in, Video out, Audio in, Audio out or Fixing screw etc.).Measuring Method: Connect milli ohm meter between earth pin in AC inlet and exposed accessible parts. See Fig.1-1-10 and grounding specifications.
AC inlet
Earth pin
Exposed accessible part
MIlli ohm meter
Grounding Specifications
Region
USA & Canada
Europe & Australia
Grounding Impedance (Z
Z 0.1 ohm
Z 0.5 ohm
)
Fig.1-1-10
AC Line Voltage
100 V
100 to 240 V
110 to 130 V
110 to 130 V
200 to 240 V
Region
Japan
USA & Canada
Europe & Australia
Insulation Resistance (R
R 1 M /500 V DC
1 M R 12 M /500 V DC
R 10 M /500 V DC
)
Dielectric Strength
AC 1 kV 1 minute
AC 1.5 kV 1 minute
AC 1 kV 1 minute AC 3 kV 1 minute
AC 1.5 kV 1 minute
(
Class
(
Class
Clearance Distance (d), (d'
d, d' 3 mm
d, d' 4 mm
d, d' 3.2 mm
d 4 m m
)
d' 8 m m (Power cord d' 6 m m (Primary wire
)
Fig.1-1-11
AC Line Voltage
100 V
110 to 130 V
110 to 130 V
220 to 240 V
Region
Japan
USA & Canada
Europe & Australia
Load Z
1
0.15
1.5
2
50
Leakage Current (i)
i 1 mA rms
i 0.5 mA rms
i 0.7 mA peak i 2 mA dc
i 0.7 mA peak i 2 mA dc
a, b, c
Exposed accessible parts
Exposed accessible parts
Antenna earth terminals
Other terminals
Fig.1-1-12
NOTE :
These tables are unofficial and for reference only. Be sure to confirm the precise values for your particular country and locality.
)
)
)
1-4 (No.PA019)
Page 5
1.1.3 Warning and caution labels
• Labels advising of warning and caution are affixed on and in various locations of the product.
• Take careful notice of these during service and inspection.
WARNING Risk of lethal or otherwise serious personal injury. CAUTION Risk of personal injury and damage to the product.
Class Pictorial Label advisory Location
WARNING
WARNING
Hot, breakable This projector lamp emits high heat and contains high-pressure during use.
If touched, the lamp (bulb) may rupture and burns may result. Before attempting to replace the lamp, remove the power cord plug from the outlet and wait for the lamp (bulb) to cool (at least one hour). Then proceed to replace the lamp.
High voltage Never open any cover on the projector except the lamp and filter covers.
Dangerous electrical voltage inside the projector.
Bottom chassis
Bottom chassis
WARNING
CAUTION
CAUTION
CAUTION
High brightness Never look into the lens while the projector is on.
There is danger of eye damage.
Hot, shock hazard
High voltage
Hot Caution, high temperature Lamp unit
Do not insert foreign objects into the ventilation holes as this can result in fire or electrical hazards. Do not block the ventilation holes as this may cause the internal temperature to rise and possibly result fire. When the inside of the unit requires cleaning, consult your nearest JVC dealer or service center.
Turn off before opening this lamp cover. See user's manual for replacing the
lamp. Replace with the same type (BHL5006-S) lamp rated 250W.
Top cover
Bottom chassis
Bottom chassis
1.1.4 Additional cautionary items
• High voltage is applied for lighting the lamp. During adjustments and other work with the cover removed, extreme care is needed to avoid electric shock.
• Use care to avoid touching the fan or safety switch terminals during work with the cover removed.
• Select a stable, horizontal work site to prevent dropping the product and components.
• Use the power cord and interface cable supplied with the product.
Before starting work, be sure to also check the safety notices contained in the instruction manual.
(No.PA019)1-5
Page 6
1.2 INSTALLATIONS
1.2.1 Installation method
The D-ILA system (reflecting type active matrix liquid crystal system) does not require convergence adjustment. Note the following when placed on a floor (refer to OPERATING INSTRUCTIONS for actual operating method).
(1) Place the projector at the position needed for the required image size observe the projector is not tilted horizontally.
[The image size is 40 to 200(wide side) inches diagonal (16:9), requiring a projection distance of 1.58m to 8.03m (wide side).] (2) Adjust the placement site and screen tilt so that the projection angle is perpendicular to the screen. (3) Adjust the placement site and screen position (height) so that the projection lens center is at the lower edge of the screen. (4) Project an image on the screen. (Connect video equipment and power source, switch power on and select the input.) (5) Fine adjust the projected image position and angle. If adjusting the placement site and screen cannot correct the projected po-
sition (too low) or angle (lower part of image widened), adjust the front foot. (6) Turn the lens ZOOM ring by hand and adjust for suitable image size. (7) Turn the lens FOCUS ring by hand and adjust to correct image blur.
1.2.2 Installation site and status
• The projector contains a fan for cooling. Obstruction of the ventilation openings can lead to internal overheating, abnormal operation and failure. Also observe there is plenty of free space between the projector and adjacent walls, ceiling and other equipment. Note that excess heat can cause failure and damage to both the projector and nearby equipment.
Required spacing :
Front = 15cm / left and right sides = 30cm / rear = 50cm (When the unit is enclosed with block according to the required spacing on the left side, provide the unit with adequate ventilation so that the temperature inside of the enclosed area is kept at the same temperature in the open space in the room.)
• Avoid locations that are wobbly or inclined. If the setting site floor has protrusions or horizontal cannot be maintained, there is risk the projector may drop, fall over, etc. If located in a site where left to right tilt is greater than ±5° and front to rear tilt greater than ±20°, particularly the optical system components can be severely affected and there is risk basic performance and quality of the projector cannot be maintained.
• Observe the site can stably bear the weight (approx. 6.2kg) of the projector over a long period of time.
• If mounted on a stand with casters, observe the casters are securely braked to prevent movement.
• Avoid suspending in a location subject to vibration. Both the projector and mounting fixture can be damaged.
• Do not place in the following types of locations. Especially, Avoid locations subject to dust, grit, smoke or other airborne contaminants. Use adequate caution when providing exter­nal ventilation, filters and dust protection.
Near water or in humid sites Near heaters or heat generating equipment Dust or grit Direct sunlight Oily or tobacco smokes Very high or very low temperature
1-6 (No.PA019)
Page 7
SPECIFIC SERVICE INSTRUCTIONS
TOP VIEW (Operation Panel)
2.1 FUNCTIONS
2.1.1 LED indications
The LED operations are as follows.
OPERATE LED
Lighted : Power on mode in progress. Extinguished : Mode other than above.
STAND-BY LED
Lighted : Stand-by mode in progress. Flashing : Cool down mode in progress. Extinguished : Mode other than above.
TEMP LED
Flashing : Internal temperature abnormally high
(shift to emergency mode) .
Extinguished : Internal temperature normal.
2.1.2 Operation button & LED location
TOP VIEW (Operation Panel)
TEMP LED
LAMP LED
SECTION 2
LAMP LED
Lighted : Lamp replacement time near (used approx.1900
Flashing : Lamp end of life (approx. 2000 hours), power
Extinguished : Mode other than above
NOTE :
Please refer to troubleshooting about the warning display by LED.
LAMP TEMP
STAND BY
OPERA TE
hours) At power on, message appears by the on­screen display for advising to "LAMP REPLACE".
on inhibited.
(lamp abnormally absent) .
STAND BY LED
OPERATE LED
MENU BUTTON
CURSOR BUTTON
PRESET BUTTON
2.1.3 Input / output terminal location
SYNC OUT RS-232CSERVICE DVI INPUT
SYNC
OUT
SERVICE
RS-232C
CONTROL
RIGHT SIDE
MENU
PRESET
DVI
VIDEO IN
OPERATE BUTTON
EXIT
ENTER
HIDE
EXIT BUTTON
ENTER BUTTON
HIDE BUTTON
LEFT SIDE
POWER INPUT
(No.PA019)1-7
Page 8
2.2 LAMP UNIT INSTRUCTIONS
Refer to the OPERATING INSTRUCTIONS for a detailed oper­ating description.
2.2.1 Lamp life
Life of the projector lamp (time to reach 1/2 average brightness) is about 2000 hours. Lamp use time can be checked at the menu < Information > -
[Lamp time].
LAMP UNIT : BHL5006-S
2.2.2 Operation when lamp use time exceeds 1900 hours
z 1900 to 2000 HOURS
• Power on : LAMP LED lights.
• Operation : "Lamp replacement" message appears on
screen (press any button to extinguish).
z 2000 to 2010 HOURS
• Power on : LAMP LED flashes.
• Operation : "Warning" and "Lamp replacement" messages
appear on screen, and "Warning" flashes. Press [EXIT] button to extinguish the display. But after 1
hour, "Warning" and "Lamp replacement" again appear.
NOTE:
At power off, the stand-by mode is produced and further op­eration is prevented. To again use the projector, replace the lamp unit and reset
the lamp use time indication.
z AFTER 2010 HOURS
• Power on : Power is cut and cool-down mode entered,
LAMP and OPERATE LEDs flash.
2.2.3 Handling cautions
• Use a cross-head screwdriver to take out and reinstall the lamp
cover (2 screws) and lamp unit (2 screws). Refer to the OPER­ATING INSTRUCTIONS.
• Observe the following cautions.
- Be sure to disconnect the power cord from the AC power source.
- The lamp remains quite hot after power off. Be sure to allow plenty of time (30 minutes to 1 hour) to cool before proceed­ing.
- The lamp can break if dropped or subjected to physical shock.
- Use care not to directly touch or soil the lamp projecting (glass) face.
• When installing the lamp unit, observe the interior projections of the lamp cover are securely inserted into the holes of the projector. Since the lamp cover projections engage the inter­lock switch part of the protector circuit (normal operating state), be sure the cover is properly positioned and secure with screws.
• The replaced old lamp (depleted lamp unit) can be discarded in the same manner as a fluorescent lamp. Check local ordi­nances and dispose of the used lamp as prescribed.
2.2.4 Lamp use time reset
• Be sure to reset the Lamp use time after replacing the lamp unit. Unless reset, the projector will cease operation (lamp will not light) when 2000 hours are reached. Conversely, reset the use time only after replacing the lamp.
• RESETTING
(1) Set for stand-by mode. (2) In sequence, press the [EXIT], [HIDE] and [PRESET]
buttons.
(3) Press the [] button for more than 2 seconds.
The STAND-BY and OPERATE LEDs alternately flash
for about 3 seconds, then only the STAND-BY LED lights steadily.
• RESET AFTER REPLACING MAIN PWB ASS'Y The lamp use time data are stored in memory on the MAIN PWB ASS'Y and need to be reentered after replacing the MAIN PWB ASS'Y. Use the special software and a personal computer to reenter the data. Afterwards, confirm the mode has been returned to that prior to board replacement.
1-8 (No.PA019)
Page 9
2.3 PROJECTION SPECIFICATIONS AND NOTES
2.3.1 Projection distance
• The usable projection distance (focus obtainable) is tele side : approx. 2.07m to 10.45m / wide side : approx. 1.58m to 8.03m. The picture size (16:9) is 40 to 200 inches.
• Use the wide side for sizes bigger than 200 inches.
• If picture edge distortion occurs at the minimum distance (1.6m), increase the distance slightly.
• The guaranteed projection distance range is from 2m to 10m.
2.3.2 Projection image and image size
• The projection distances and image size relationship given in the operation manual is approximate for general reference. The actual values may vary due to lens tolerance and other factors.
2.3.3 Other cautions
• Use care not to directly touch the lens. Clear soiling from the lens with optical lens paper or a photographer's blower.
• Check the lens cap is removed before projecting. If left in­stalled the projector can overheat and the lens cap can be de­formed.
• Sunlight or other illumination can render the image difficult to see. Use a curtain or other means to shield the screen from stray light.
2.4 CONNECTION AND OPERATION CAUTIONS
• The projector can function with fH 56.25kHz, 67.43kHz,
67.5kHz, fV 50Hz, 59.94Hz, 60Hz signal input, but even within this range, partial picture loss, fold-over at the top and bottom picture edges and other effects can occur according to signal type and conditions to prevent a normal projected image (see "Input Sync Frequency" of the OPERATING INSTRUCTION).
2.5 SERVICE POLICY
The following service policy is being utilized.
Item Parts number Service method
MAIN PWB ASS'Y LCA90233-01B Replace PWB (Some parts are excluded) DD SUB1 PWB ASS'Y LCA90234-01B Replace PWB (Some parts are excluded) DD SUB2 PWB ASS'Y LCA90235-01B Replace PWB (Some parts are excluded) POWER PWB ASS'Y LCA10383-01A Replace parts IR1 PWB ASS'Y LCA90271-01B Replace parts IR2 PWB ASS'Y LCA90236-01B Replace parts CONT. & 3.3V PWB ASS'Y SXG-0P002A Replace parts OPERATION PWB ASS'Y LCA90272-01B Replace parts OPTICAL BLOCK ASS'Y HD2KOP-S Replace (module) LAMP BALLAST UNIT QAL0435-002 Replace (module) LAMP UNIT BHL5006-S Replace (module)
2.6 MAIN DIFFERENCE LIST
Part name DLA-HD2KU DLA-HD2KE Remark
PACKING CASE LC21468-005A LC21468-008A POLY BAG QPA01503005 -------- For Warranty card WARRANTY CARD BT-51030-3 -------- Accessory
POWER CORD QMPE240-250-R
QMPL280-200-R (for EU) QMPP220-200-R (for UK)
Accessory
(No.PA019)1-9
Page 10
2.7 SERVICE MENU
options
software version
software version
options
The service menu contains items not ordinarily needed by the us­er. Use these as necessary during service.
2.7.1 Enter
(1) No menu shown. (2) Press the [] button. (3) Within press the [] button. (4) Within press the [] button. (5) Within press the [] button. (6) Within press the [ENTER] button to display the service
menu.
NOTE:
When the Service Menu Screen is not displayed, go back to the beginning. It is recommended that you press the buttons a little earlier and steadily.
2.7.2 Release
Press the [MENU] button to exit the menu indication.
2.7.3 Basic operation
Use the following buttons to operate the service menu.
(1) Choose the SETTING MENU with the [/] button. (2) When the [] button is pressed after choosing the SET-
TING MENU, the cursor will shift to the SETTING / AD­JUSTMENT ITEMS of each SETTING MENU.
(3) When the cursor is shifted, choose the SETTING / AD-
JUSTMENT ITEMS with the [/] button.
(4) Using the [/] button, change the setup values and ad-
justment values, respectively.
(5) When the [EXIT] button is pressed, the cursor will return to
the SETTING MENU.
(6) When the [MENU] button is pressed, the SERVICE MENU
will go out of the screen.
NOTE:
The SERVICE MENU will go out of the screen automatically after 10 seconds if you do not press the [MENU] button.
SERVICE MENU
SETTING NENU SETTING / ADJUSTMENT ITEM
software version
࠰ࡈ࠻ࡃ࡯ࠫ
options
software version
options
PRG : 014
OSD : 011
DLA-HD2K
Software version SCREEN
Back Color Black
Auto shut off Off
Color temp.
RED
GREEN
BLUE
Factory reset
Adjust pattern
Option SCREEN
Blue
On
USER1 D65 USER2
0
0
0
ENTER
ENTER
1-10 (No.PA019)
Page 11
2.7.4 Setting items
software version
options
Item Initial value
Adjustment
range
Description
Setting
object
Software version Software version ------ ------ Information of PROGRAM -----­Option Back color Blue [Select 2 items] "Sets no signal background color to blue or black.
Common
[Blue] : Blue color [Black] :Black color"
Auto shutdown ON [Select 2 items] If POWER OFF is selected, no warning will be displayed on and
Common after 1900 hours of the lamp operating time. However, POWER ON is also available after 2000 hours of the lamp operating time.
Color temp D65 Select 3 items Setting of [D65]:6500K, USER1, USER2 Common R 0 -255~0 Setting color temp of red Common G 0 -255~0 Setting color temp of green Common B 0 -255~0 Setting color temp of blue Common Factory reset ------ ------ Press [ENTER] then all reset. Common Adjust pattern ------ [Select 5 items] Press [ENTER] then Test pattern appear. (Refer to following Fig.1) Common
Test patter Screen
convergence
software version
options
SERVICE MENU Screen
Back Color Black
Auto shut off Off
Color temp.
RED
GREEN
BLUE
Factory reset
Adjust pattern
Blue
On
USER1 D65 USER2
0
0
0
ENTER
ENTER
checkercross-hatch
(When the key is pressed, the screen is changed one after the other as shown in the above.)
(No.PA019)1-11
Page 12
2.8 FACTORY SHIPPING SETTING
SET (PROJECTOR) / REMOTE CONTROL UNIT
Switch / Item
MAIN POWER VIDEO HIDE
MENU
Item
Image adjust
Gamma Color temp. Color temp. RED GREEN BLUE Test pattern
Set up
Menu Position Mask Source
Position
OFF VIDEO OFF (display)
Position
2.2
ENTER
D65 0
This adjustment is only available when the USER is
0
selected for color temperature.
0
ENTER
CENTER Off 60p
Item Position
Options
Menu display Flip H Flip V Picture Shift Sleep time RS232C (bps)
15sec Off Off 0 Off 19200
Information
Lamp time < Lamp usage time >
1-12 (No.PA019)
Page 13
SECTION 3
DISASSEMBLY
Notes:
• Confirm that the power cord is unplugged from the AC outlet before proceeding.
• The lamp remains quite hot after turning the power off. Allow sufficient time to cool before starting work.
3.1 LENS COVER
(1) Rotate the LENS COVER on the front of the main frame
counterclockwise and release the lock. Then pull out the LENS COVER toward you. (Fig.1)
3.2 LAMP UNIT COVER
(1) Loosen the 2 screws marked A on the right side of the main
frame and pull out the LAMP UNIT COVER toward you. (Fig.2) These 2 screws are not removed from the LAMP UNIT COVER.
3.3 TOP COVER
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER. (1) Remove the 1 screw marked B and the 2 screws marked C
on the right side of the main frame. (Fig.2)
(2) Remove the 3 screws marked D on the left side of the main
frame. (Fig.2)
(3) Remove the 1 screw marked E on the rear side of the main
frame. (Fig.2)
(4) Remove the harness from the connector CN701
CONTROL UNIT which is secured to the back of the TOP COVER.
(5) Lift up the TOP COVER to remove it.
3.4 PROTECT COVER
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER. (1) Remove the 1 screw marked E' fixing the PROTECT COV-
ER, and lift up the PROTECT COVER to remove it. (Fig.2)
3.5 CONTROL UNIT
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER. (1) Remove the 5 screws marked F fixing the CONTROL UNIT
from the back of the TOP COVER. (Fig.2)
(2) Remove the CONTROL UNIT. (Fig.2)
of the
LENS COVER
Fig. 1
D
(x3)
(x1)
CN710
TOP COVER
E'
F
(x5)
CONTROL UNIT
C
(x1)
E
(x1)
A
(x2)
LAMP UNIT COVER
BOTTOM CHASSIS
Fig.2
C
(x2)
B
(x1)
(No.PA019)1-13
Page 14
3.6 TERMINAL PWB ASS'Y AND MAIN PWB ASS'Y
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER. (1) Remove the 6 screws marked J fixing the MAIN PWB
ASS'Y. (Fig.3)
(2) Remove the harness from the connectors CN710
.
CN711
(3) Remove the cord wire from the connector CN504 and
.
CN505
(4) Remove the harness from the connectors CN501
, CN502,
CN503, CN714, CN707, CN706, CN705, CN713, CN704
and CN708.
3.7 TERMINAL BOARD AND SHIELD SHEET
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y. *1
and
(1) Remove the 4 screws marked G fixing the TERMINAL
BOARD. (Fig.3) (2) Remove the TERMINAL BOARD. (3) Using a nut driver and the like, remove the 4 screws
marked H fixing the D-SUB connector and DVI connector.
(Fig.3) (4) Pull out the SHIELD SHEET toward you to remove it.
*1
After (2) in the procedure above, the TERMINAL BOARD and the SHIELD SHEET can be replaced. However, be careful about the cord wire and the harness that are not replaced.
3.8 MAIN PWB ASS'Y
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the TERMINAL BOARD and the SHIELD SHEET. (1) Remove the 1 screw market K and the 6 screws marked J
fixing the MAIN PWB ASS'Y.
CN714
CN707
CN706
CN705
CN713
CN704
CN708
CN701
CN505
CN503
CN504
K
CN502
CN501
(x1)
CN711
CN710
J
(x6)
MAIN PWB ASS'Y
SHIELD SHEET
H
(x4)
TERMINAL BOARD
G
(x4)
1-14 (No.PA019)
Fig.3
Page 15
3.9 LAMP UNIT UPPER BRACKET
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y. (1) Remove the 2 screws marked M fixing the LAMP UNIT UP-
PER BRACKET. (Fig.4)
(2) Pull out the LAMP UNIT UPPER BRACKET in the direction
of the arrow.
3. 10 POWER SUPPLY SHIELD CASE(1) and LAMP BALLAST UNIT
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the LAMP UNIT UPPER BRACKET. (1) Remove the 5 screws marked N fixing the POWER SUP-
PLY SHIELD CASE(1). (Fig.4)
(2) Disconnect the connectors CN1
and CN2.
(3) Remove the 1 screw marked O fixing the LAMP POWER
SUPPLY CORD SUPPRESSION BRACKET. (Fig.4)
(4) Lift up the LAMP POWER SUPPLY CORD SUPPRES-
SION BRACKET to remove it, and remove the LAMP POWER SUPPLY CORD.
(5) After setting up the POWER SUPPLY SHIELD CASE(1),
remove the 4 claws marked a which secure the LAMP BAL­LAST UNIT to the back of the POWER SUPPLY SHIELD CASE. (Fig.4)
N
(x5)
LAMP BALLAST UNIT
POWER SUPPLY SHIELD CASE(1)
CN2
CN1
M
(x2)
a
LAMP UNIT UPPER BRACKET
O
(x1)
LAMP POWER SUPPLY CORD SUPPRESSION BRACKET
LAMP POWER SUPPLY CORD
Fig.4
(No.PA019)1-15
Page 16
3.11 POWER SUPPLY PWB ASS'Y
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the LAMP UNIT UPPER BRACKET.
• Remove the POWER SUPPLY SHIELD CASE(1). (1) Remove the 4 screws marked P fixing the POWER SUP-
PLY PWB ASS'Y. (Fig.5)
(2) Disconnect the POWER SUPPLY CORD from the connec-
tor CN001
.
(3) Pull out the harness from the THERMOSTAT PROTEC-
TOR.
(4) Pull out the POWER SUPPLY CONTROL MODULE PWB
ASS'Y from CN005. (Fig.5)
3.12 POWER SUPPLY CONTROL MODULE PWB ASS'Y
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the LAMP UNIT UPPER BRACKET.
• Remove the POWER SUPPLY SHIELD CASE(1). (1) Pull out the POWER SUPPLY CONTROL MODULE PWB
ASS'Y from the connector CN005
of the POWER SUPPLY
PWB ASS'Y. (Fig.5)
3.13 POWER SUPPLY SHIELD CASE(2), RADIATION FAN, INTERLOCK SWITCH, COOLING FAN1, DUCT1
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the POWER SUPPLY SHIELD CASE(1).
• Remove the POWER SUPPLY PWB ASS'Y.
(1) Remove the 4 screws marked Q fixing the POWER SUP-
PLY SHIELD CASE(2). (Fig.5)
(2) Lift up the POWER SUPPLY SHIELD CASE(2) to remove
it.
(3) Remove the 2 screws marked R fixing the RADIATION
FAN to the POWER SUPPLY SHIELD CASE(2). (Fig.5)
(4) Remove the 1 screw marked S fixing the INTERLOCK
SWITCH to the POWER SUPPLY SHIELD CASE(2), and remove the INTERLOCK SWITCH. (Fig.5)
(5) Remove the 2 screws marked b fixing the DUCT1. (Fig.5) (6) Remove the 2 screws marked c fixing the COOLING
FAN1. (Fig.5)
b
(x2)
c
(x2)
COOLING FAN1
POWER SUPPLY CONTROL MODULE PWB ASS'Y
CN005
DUCT1
POWER SUPPLY SHIELD CASE(2)
CN001
P
(x4)
R
(x2)
Q
(x4)
RADIATION FAN
S
(x1)
INTERLOCK SWITCH
THERMOSTAT PROTECTOR
1-16 (No.PA019)
Fig.5
Page 17
3.14 IR2 PWB ASS'Y
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y. (1) Remove the 1 screw marked T fixing the IR2 PWB ASS'Y.
(Fig.6)
(2) Lift up the IR2 PWB ASS'Y to remove it.
3.15 OPTICAL BLOCK, INTAKE FAN
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y. (1) Remove the 1 screw marked o fixing the LAMP POWER
SUPPLY CORD SUPPRESSION BRACKET. (Fig.4) (2) Pull out the LAMP POWER SUPPLY CORD (3) Remove the 2 screws marked j fixing the THERMOSTAT
PROTECTOR. (Fig.6) (4) Remove the 2 screws U and 3 screws v fixing the OPTICAL
BLOCK. (Fig.6) (5) Remove the 1 screw k fixing the EARTH BRACKET that
connects the OPTICAL BLOCK and the CHASSIS. (Fig.6) (6) Lift up the OPTICAL BLOCK to remove it. (Fig.6) (7) Remove the 2 screws d fixing the INTAKE FAN. (Fig.6)
3.16 DD SUB1 PWB ASS'Y (Incl. DD SUB2 PWB ASS'Y)
• Remove the LENS COVER.
• Remove the LAMP UNIT.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the PROTECT COVER.
• Remove the OPTICAL BLOCK (for easier operation). (1) Remove the 3 screws w fixing the DD SUB1 PWB ASS'Y.
(Fig.6)
(2) Remove the cord wire from the connectors CN007
and CN009
.
, CN008,
3.17 COOLING FAN2, DUCT2, COOLING FAN3, DUCT3,
DUCT4
• Remove the LENS COVER.
• Remove the LAMP UNIT COVER.
• Remove the TOP COVER.
• Remove the MAIN PWB ASS'Y.
• Remove the PROTECT COVER.
• Remove the OPTICAl BLOCK. (1) Remove the 2 screws marked e fixing the DUCT2. (Fig.6) *2 (2) Remove the 2 screws marked f fixing the COOLING FAN2.
(Fig.6) *2 (3) Remove the 3 screw marked i fixing the DUCT4. (Fig.6) *2 (4) Remove the 1 screw marked g fixing the DUCT3. (Fig.6) (5) Remove the 1 screw marked h fixing the COOLING FAN3.
(Fig.6)
*2
This operation is easier if OPTICAL BLOCK is removed.
CN009
CN007
CN008
INTAKE FAN
DD SUB1 PWB ASS'Y
w
(x3)
d
(x2)
OPTICAL BLOCK
DUCT4
(x3)
i
(x3)
COOLING FAN2
f
(x2)
v
DUCT2
COOLING FAN3
(x2)
(x1)
g
h
U
(x2)
k
(x1)
DUCT3
(x1)
T
(x1)
IR2 PWB ASS'Y
j
(x2)
THERMOSTAT PROTECTOR
LAMP UNIT FIXING SCREWS (x2)
e
BOTTOM CHASSIS
Fig.6
(No.PA019)1-17
Page 18
SECTION 4
ADJUSTMENT
4.1 BEFORE STARTING ADJUSTMENT
(1) Adjustment items utilize a personal computer.
This instruction is for HD2 PSA CONTROL PROGRAM
Program. Use the latest version program. (2) Data back up is required before adjustments. (3) Allow the equipment and test instruments adequate time
(at least 30 minutes) to warm-up. (4) Confirm the set is properly connected to the specified AC
power source. (5) Use care not to disturb internal controls and parts not spe-
cifically mentioned. (6) Unless specifically mentioned in the "ADJUSTMENT PRO-
CEDURE" steps, do not change any data.
4.2 INSTRUMENTS AND TOOLS
• Oscilloscope
• Light meter [for example: Minolta T-10]
• Color-meter [CL-200]
• Remote control unit [RM-MH2K]
• Personal computer
Operating system Windows 98 ME 2000 XP Memory More than 16 Mbytes Hard disk free space More than 5 Mbytes RS-232C interface At least 1 port Display resolution Minimum : 800 × 600 pixels
Recommended : 1024 × 768 pixels or better
Display colors Minimum : 8 bits/pixel
Recommended : 16 bits/pixel or better
Input devices Keyboard and mouse
• Adjustment software : HD2 PSA CONTROL PROGRAM
• RS-232C 9pin NULL-MODEM (cross) cable
• Photoelectric conversion device (one of these)
Light meter [Minolta T-10] A-out (Analog output)Photoelectric conversion device (for example: HAMAMAT-
SU PHOTONICS S1226-8BK)
Phototransistor or CdS photoconductor with amplifier
• Color filters
G color filter (ex. MELLES GRIOT 03 FIV 044)R color filter (ex. MELLES GRIOT 03 FIB 014)B color filter (ex. MELLES GRIOT 03 FIV 028)
• Screen
• Darkroom (illumination less than 0.03 lx)
< Use these instruments and tools if necessary >
• NTSC / PAL signal generator : composite output, Y/C output
Gray scale : 0IRE-100IREColor bar : include 75% white peak
• NTSC signal generator : composite output [Y / CB / CR] Flat (raster) pattern : 10%
• HDTV signal generator : composite output [Y / PB / PR] Flat (raster) pattern : 10%
• PC signal generator Signal : VGA / SXGA Gray scale : 0.7V (p-p) [include 100% White / 0% Black] Show at least 2 images on 1 screen (Upper scale and Lower
scale must be reversed)
Cross-hatchFlat (raster) pattern : 100%, 93%, 13%, 0%
1-18 (No.PA019)
Page 19
4.3 REQUIRED ADJUSTMENTS BY REPLACING COMPONENTS
The following adjustment procedure is required after replacing PWB ASS'Ys, LAMP BALLAST UNIT and OPTICAL BLOCK. Items noted as "Check" means check the condition, then adjust if required.
4.3.1 Component required adjustment at replacing
Adjustment items MAIN DD SUB1.2 POWER
LAMP
BALLAST
OPTICAL
BLOCK
1. D-ILA COMMON DC Check Required Check Check Required
2. DC (GAMMA) Check Required Check Check Required
3. GAMMA (GRADATION / WHITE BALANCE) Check Required Check Check Required
4. SHADING (UNIFORMITY) Check Check Check Required
5. 16 - PHASE VERTICAL BARS Check Required Required
6. GHOST Check Required
7. FRAME Check Required
4.3.2 List of required instruments and tools (except those related to the personal computer)
Adjustment items
OSCILLOSCOPE
Light meter Color filter Color meter
1. D-ILA COMMON DC (Required)
2. DC (GAMMA) (Required)
3. GAMMA (GRADATION / WHITE BALANCE) Required Required Required
4. SHADING (UNIFORMITY) Required Required
5. 16 - PHASE VERTICAL BARS Required
6. GHOST
7. FRAME
4.3.3 Data backup
Before replacing major components such as PWB ASS'Ys, UNIT or BLOCK, be sure to backup the data contained in the set. In absence of data backup, complete adjustment becomes necessary.
z PREPARATION
(1) Make sure that Version.ini file is located in the same folder of the PSA controller. (2) Remove all signal cables except for the interface cable to the PC from the main body.
z DATA SAVE
(1) Enter Stand-by mode and open the PSA controller on the PC. (2) Click [System] in the main menu. When the pull down menu is displayed, click [Backup ROM Data] and open ROM Data Up
Load/Down Load.
(3) Tick [Main EEPROM] and [Sub EEPROM] in [Target EEPROM]. (4) When [Down Load] is selected, data will be downloaded in the order of EEPROM EEPROM2 SUB EEPROM. (5) When the download has completed, Save Data with File Name dialog box will be displayed. Then save the data with a file
name.
z DATA ENTRY
(1) Enter Stand-by mode and open the PSA controller on the PC. (2) Click [System] in the main menu. When the pull down menu is displayed, click [Backup ROM Data] and open ROM Data Up
Load/Down Load. (3) Tick [Main EEPROM] in [Target EEPROM]. (4) When [Down Load] is selected, Open dialog box will be displayed. Then select a file which you want to upload. (5) The data will be downloaded in the order of EEPROM EEPROM2 SUB EEPROM.
(No.PA019)1-19
Page 20
4.4 ADJUSTMENT PROCEDURE
4.4.1 D-ILA COMMON DC adjustment
Instruments PSA Software for HD2K
Oscilloscope
Photo sensor Test point Adjustment menu < DDIC > Preparation Running the unit enough before adjustment
Note :
Large deviation of this adjustment can cause image flicker. Residual image or element burn can occur when out of adjustment.
PREPARATION
(1) Connect the PC and the Projector with an RS 232C cable and turn the projector ON. (2) Boot the SPA software. (3) Click [Connect] in the Menu Bar and select [Auto Connect] in the pull down menu. Refer to Fig.1.
REPLACING COMPONENTS
z DD SUB1.2 PWB ASS'Y z OPTICAL BLOCK
Fig.1 (4) Press the [DDIC] button in the SPA screen. The DDIC Control screen will be displayed accordingly. (5) Press [Receive All] at the top right of the screen. (6) Press [R] at the top left of the screen. Set the following buttons located in the furthest right of the screen as follows: Set
[GINDAT],[SUPDAT],[DCSDAT] to ON, and the rest to OFF. Refer to Fig.2.
(6)Set these button to ON.
(7)Set to 90.
Fig.2 (7) In the [DDIC] [Control EVR tag] screen, set the value for DC_R, DC_G and DC_B to 90, respectively. Refer to Fig.2. (8) Put the photo-sensor at 40 cm away from the surface of the Projector lens (Screen center) and connect the sensor to the
oscilloscope.
1-20 (No.PA019)
Page 21
ADJUSTMENT
A
(9) On the [DDIC Control][Flat Field] tag, set the Flat Field Level value for a color to be adjusted to 512 and the rest to 0,
respectively. Refer to Fig.3.
(9)Enter 512.
Fig.3
(10) In the [DDIC Control][EVR] tag, find the point by sliding a CC slider (CC_R for red, CC_G for green and CC_B for blue) where
the photo-sensor waveform becomes minimum . Refer to Fig.4.
djust here
Fig.4
(11) Perform the above procedures (9) and (10) for all colors, R, G, and B.
(No.PA019)1-21
Page 22
4.4.2 DC adjustment
Instruments PSA Software for HD2K
Excel file for GAMMA adjustment Color-meter (CL-200)
REPLACING COMPONENTS
z DD SUB1.2 PWB ASS'Y z OPTICAL BLOCK
Test point Adjustment menu < DDIC > < Gamma > Preparation Running the unit enough before adjustment.
PREPARATION
(1) Connect the PC and Projector, PC and CL200 with RS-232C cables and then turn the Projector ON. (2) Boot the SPA software. (3) Click [Connect] on the Menu Bar and select [Auto Connect] in the pull-down menu. Refer to Fig.1.
Set these parameters to ON
Fig.1
Fig.2
(4) When the connection is completed, press the [DDIC] button. The [DDIC Control] screen will appear. (5) Press the [Receive All] button at the top right of the screen. (6) Press the [R] button at the top left of the screen. Of the buttons located at the furthest right of the screen, set [GINDAT],
[SUPDA][DCSDAT] and [RVSDAT] to ON, and the rest to [OFF].
Refer to Fig.2 (7) Click [DisConnect] in the PSA menu to disconnect the connection. (8) Put the CL200 at 40cm away from the projector lens surface (Screen center) and turn the CL200 to ON.
MEASUREMENT
(9) Open the Gamma adjustment file and click [CONNECT] in the [DC] sheet.
(10) Click [MEASURE] when [OK] is shown. Refer to Fig.3.
(10)Click here
(9)Click here
Confirm [OK]
Fig.3
(11) When the measurement is completed, click [CONNECT] in step 10) to disconnect the system. Boot the PSA software to
connect the PC and the Projector.
(12) On completion of the measurement, enter the values in red in the [D43], [T43] and [AJ43] cells to [DC_R], [DC_G] and [DC_B],
respectively.
(13) Click [DisConnect] in the PSA screen to disconnect the system. The Gamma adjustment is to be performed next.
1-22 (No.PA019)
Page 23
4.4.3 GAMMA adjustment
Instruments PSA Software for HD2K
Excel file for Gamma adjustment Color-meter (CL-200)
REPLACING COMPONENTS
z DD SUB1.2 PWB ASS'Y z OPTICAL BLOCK
Test point Adjustment menu < DDIC > < Gamma > Preparation Completed D-ILA COMMON DC adjustment
PREPARATION
(1) Open the Black (GAMMAOFF) sheet in the GAMMA adjustment file and click [CONNECT] in the same way as the DC
adjustment. Refer to Fig.1. (2) On completion of the connection, click [MEASURE]. Refer to Fig.1. (3) On completion of the measurement, click [CONNECT] again to disconnect the system. Refer to Fig.1.
(1)Click
(2),(3)Click
Fig.1
(4) Open the É¡ calculation sheet in the GAMMA adjustment file (GAMMAOFF_1.0_without color compensation). Click [CREATE
FILE] near the BK16 cell and save it with an appropriate file name. (5) Connect the PSA and click [Gamma] on the PSA screen. (6) Click [CUSTOM] on the Gamma correction screen. Refer to Fig.2. (7) Right-click on the Gamma curve in the [Gamma Correction] screen to select [Load CUSTOM Data] and then select the file
saved in step 3). (8) Click [RGB Transmit All] on the [Gamma correction] screen. Refer to Fig.2.
(7)Select
Fig.2
(9) Click [DDIC] in the SPA menu and set [GAMDAT] to [ON] as shown in Fig.3.
Refer to Fig.3.
(6)Click
(8)Click
(9)ON
Fig.3
(No.PA019)1-23
Page 24
(10) Click [DisConnect] in the SPA menu to disconnect the system. (11) Open the sheet [CHROMATICY MEASUREMENT(RGB)] in the Gamma adjustment file. (12) Similarly, click [CONNECT]. Refer to Fig.4. (13) When the connection is competed, click [MEASURE]. Refer to Fig.4. (14) When the measurement is completed, click [DISCONNECT] to disconnect the system. Refer to Fig.4. (15) Confirm if the three graphs shown on the [CHROMATICY MEASUREMENT(RGB)] sheet are linear. If not, the result is
determined to be FAILED.
(12)Click
(13)Click
(14)Click here
Fig.4 (16) Open the y calculation sheet in the GAMMA adjustment file (GAMMAOFF_1.0_with color compensation). (17) Click [CREATE gcd FILE] near the BK16 cell in the sheet and save it with an appropriate file name. (18) Perform the procedures in step 5), 6), 7) and 8). Please note the file to be loaded is the one that is saved in step 17). (19) Select the [R] button in the [Gamma correction] screen. Refer to Fig.4. (20) Right-click on the Gamma curve in the Gamma correction screen to select [Copy Gamma Data].
Refer to Fig.4.
(19)Select
Confirm
(20)Select
Fig.4 (21) Select [Gamma2.2] in the [Gamma correction] screen. Refer to Fig.5. (22) Right-click on the Gamma curve in the [Gamma correction] screen to select .[Paste Gamma Data]. Confirm that the Gamma
curve for [R] is pasted. Refer to Fig.5.
(21)Select
(22)Select
(24)Click
Fig.5 (23) Perform the procedures in step (19), (20), (21) and (22) for [G] and [B], as well. (24) When step (23) is completed, click [RGB Transmit All]. Refer to Fig.5.
1-24 (No.PA019)
Page 25
(25) Right-click on the [Gamma2.2] curve in the [Gamma correction] screen. Select [Make CUSTOMData] and the [Gamma1.8] to
allow the Gamma1.8 data to be input to [CUSTOM]. Refer to Fig.6.
(25)Select
Fig.6 (26) Copy the [CUSTOM] data, as previously performed in step (19), (20), (21), (22), (23) and (24), to paste these to [Gamma1.8]. (27) Perform the same procedures as steps (25) and (26) and create the data for Gamma2.6 in [Gamma2.6]. (28) In [CUSTOM] the same data as Gamma2.2 are to be input. To do this, right click on the Gamma curve in the [Gamma
correection][Gama2.2] screen. Select [Make CUSTOM Data], then [Gamma2.2] to allow the Gamma2.2 data to be input to [CUSTOM].
(29) Save the Gamma adjustment file and close the file. The Gamma adjustment is now completed.
(No.PA019)1-25
Page 26
4.4.4 SHADING adjustment
Instruments SVGA signal generator
Light-meter Test point Adjustment menu < DDIC > < Area Shading > Preparation Completed GAMMA adjustment
REPLACING COMPONENTS
z DD SUB1.2 PWB ASS'Y z OPTICAL BLOCK
PREPARATION
(1) When the reverse shading function is used, open Menu
[DDIC] [FPGA], and set [Left side Right] and [Up Side Down] to [Off].
(2) Open Menu [Area Shading] and, after clicking [LUM]. Set
each [R], [G] and [B] to [Default] respectively, then click [Transmit].
(3) Click [DYN] or [STC] and set [R], [G] and [B] to [Default]
respectively in the same way, then click [Transmit].
SHADING ADJUSTMENT
(1) Open Menu [DDIC] [FPGA], and set [R Mute], [G Mute]
and [B Mute] to [On]. (2) Set [R], [G] and [B] Flat Field level to 204, respectively. (3) Open Menu [Area Shading] and click [STC]. Then adjust
the screen with the slide bar for adjustment level setting
so that the screen is evenly colored. (4) Open Menu [DDIC] [Flat Field] and set [R], [G] and [B]
Flat Field level to 614, respectively. (5) Open Menu [Area Shading] and click [DYN]. Then adjust
the screen with the slide bar for adjustment level setting
so that the screen is evenly colored. (6) Open Menu [DDIC], and set [DYNDAT] [STCDAT] to
[Off]. (7) Open Menu [Flat Field] and set [R] Flat Field level to 204,
[G] and [B] Flat Field level to 0, respectively. Record the
brightness of the screen at this time (8) Set [R] Flat Field to 614 and record the brightness of the
screen at this time. (9) Return [DYNDAT] and [STCDAT] to [On].
(10) Open Menu [EVR] and adjust [R OFFSET] so that the
brightness of the screen become the same value as
those of the recorded value.
(11) Open Menu [DDIC] [Gain/Setup] and click [Gain]. Adjust
[DDIC] [GAIN] so that the brightness of the screen at the
[R] Flat Field level of 614 become the same value re-
corded in 8) above.
(12) In the same manner as for the above steps, also adjust
[G] and [B] Flat Field level.
(13) Adjust [LUM], if necessary. Keep the Flat Field level at
1023 at the center of the screen as much as you can.
(14) After adjustment, transfer the data to the reverse shad-
ing adjustment memory by clicking [Copy Shading Data
to Reverse Shading Data] on the bottom of the Area
Shading screen. At this time, open [Shading] on [Config-
uration] tool bar and set the values according to the table
on the right side so as to compensate the vertical reverse
shading gradient.
If necessary, adjust Up Side Down position. When adjusting
the Up Side Down position, hang the unit from the ceiling. Open Menu [DDIC] [FPGA] and set [Left Side Right] and [Up Side Down] to [On]. For the adjustment, follow the same man­ner as for the steps (1)~(14) above.
LUM DYN STC Vcom
R G B
button
button
Default
button
<Area Shading> Menu
[Offset] : Presetting
[Copy Shading Data to Reverse Shading Data] : Revers shading adjustment memory setting
[Cursor size] : Adjustment area setting
[Slide bar] : Adjustment level setting
STC Shading DYN Shading
Red 63 0
Green 63 0
Blue 63 0
< Compensate the vertical reverse shading gradient >
1-26 (No.PA019)
Page 27
4.4.5 16-PHASE VERTICAL BARS adjustment
Instruments PSA Software for HD2K
Phase deviation measurement circuit Phase deviation measurement Excel file
REPLACING COMPONENTS
z OPTICAL BLOCK z DD SUB1.2 PWB ASS'Y
Test point Adjustment menu < DDIC > Preparation Completed GAMMA adjustment
PREPARATION
(1) Connect the Phase Deviation Measurement circuit at CN005 with the Projector turned off.Connect the FPC to a desired color. (2) Connect the PC and Projector with a RS232C cable. Turn the projector ON and boot the SPA software. (3) Click [Connect] on the menu bar and select [Auto Connect] in the pull-down menu. Refer to Fig.1. (If [Connection failed] is
shown, the connection is FAILED. If no message appears, the connection is completed and the result is PASSED)
(10)ON (7)ON
Fig.1
Fig.2
(4) When the connection is made, press [DDIC]. The DDIC Control screen will appear. (5) Click [Receive All] at the top right of the screen. (6) Press [R] at the top left of the screen. (7) Of all buttons located at the furthest right of the screen, set [RVSDAT] to [ON] and the rest to [OFF]. Refer to Fig.2. (8) Repeat the procedure in step (7) for the [G] and [B] buttons. (9) Click the [EVR] tag in the DDIC Control screen.
(10) Set the values for [DC_R], [DC_G], [DC_B] to 90.
Refer to Fig.3.
(11) Press the [Load File] button in the [Register] tag in the DDIC Control screen. (12) Select [PHS_RGBch_Inter-Phase Deviation_Clear.txt] and press [OK] in the [CONFIRM] message box. (13) Set [R_MUTE], [G_MUTE], [B_MUTE] to ON in the [DDIC Control][FPGA] tag. (14) Copy the entire contents of the [HD2K_16 Phase Adjustment_XX . Xls] file and modify the xxx to a serial number.
(10)Set these parameters to 90
Fig.3
(No.PA019)1-27
Page 28
MEASUREMENT
(1) Open the previously renamed Excel file and select the [PHS_Rch] sheet. (2) Set the values of the [R[, [G] and [B] scroll bars to [0] in the [DDIC Control][Flat Field] tag in the [DDIC Control] screen. (3) Set the slide switch to [FORWARD] on the Phase Deviation Measurement circuit. (4) Connect the Phase Deviation Measurement circuit probe to the 1st Phase pin, a header pin on the PCB to which the FPC is
connected. Enter the value measured on the Digital Voltmeter without a minus sign to [FORWARD ROTATION] [Black] [1], or
the [B3] cell in the Excel file. Refer to Fig.4.
(4)Enter from here
(7)Enter from here
(11)Enter from here
(14)Enter from here
(17)Enter here
(18)Click
Fig.4
(5) Connect the probe to the 2nd Phase pin and enter the measured value to [B4]. Perform the procedure stated in step (4)
through to the 16th phase. (6) Set the slide switch on the Phase Deviation Measurement circuit to [REVERSE ROTATION]. (7) Connect the probe of the Phase Deviation Measurement circuit to the 1st Phase pin, a header pin to which the FPCis
connected. Enter the value measured on the Digital Voltmeter without minus sign to [REVERSE ROTATION] [Black] [1], or
the [B23] cell in the Excel file. Refer to Fig.4. (8) Connect the probe to the 2nd phase and enter the measure value to [B24]. Repeat the procedure from step (7) through to the
16th phase. (9) Of the [R], [G] and [B] in the [Flat Field]tag, set the scroll bar value of the color to be measured to [1023].
(10) Set the slide switch on the Phase Deviation Measurement circuit to [FORWARD]. (11) Connect the Phase Deviation Measurement circuit probe to the 1st phase pin, a header pin on the PCB to which the FP1C is
connected. Enter the value measured on the Digital Voltmeter without a minus sign to [FORWARD ROTATION] [White] [1],
or the [C3] cell in the Excel file. Refer to Fig.4.
(12) Connect the probe to the 2nd Phase pin and enter the measured value to [C4]. Repeat the procedure through to the 16th
phase.
(13) Set the slide switch on the Phase Measurement circuit to [REVERSE]. (14) Connect the Phase Deviation Measurement circuit probe to the 1st phase pin, a header pin on the PCB to which the FPC is
connected. Enter the value measured on the Digital Voltmeter without a minus sign to [REVERSE ROTATION] [White] [1], or
the [C23] cell in the Excel file. Refer to Fig.4.
(15) Connect the probe to the 2nd Phase pin and enter the measured value to [C24]. Repeat the procedure through to the 16th
phase.
(16) In the [Flat Field][DDIC Control] screen, set all the [R], [G] and [B] scroll bar values to [0]. (17) Set [DCSDAT] of the color under measurement to [ON]. Enter the value measured on the Digital Voltmeter without a minus
sign to the cell [B40] in the Excel file. Refer to Fig.4.
(18) Press the [CREATE FILE] button located in [C42] in the Excel file.
Refer to Fig.4.
(19) Press the [Load File] button in the [DDIC Control][Register] tag. If the Rch measurement is performed, select the
[C:\FHD\~~~.txt] file and press [OK] in the [CONFIRM] message box. Be sure to modify the xxx in the file name to a serial
number.
(20) Set [GINDAT], [SUPDAT], [DCSDAT] and [RVSDAT] to [ON]. Refer to Fig.4.
If the measured voltage differences on Phase 1 through to Phase 16 in the Phase Deviation Measurement circuit are within
+/-10 mV, the result is determined to be PASSED.
If the result is outside this range, the result is determined to be FAILED.
(21) Turn the Projector OFF. (22) Perform the procedures from step (9) for Gch and Bch.
1-28 (No.PA019)
Page 29
4.4.6 GHOST adjustment
Instruments PSA Software for HD2K REPLACING COMPONENTS Test point
z OPTICAL BLOCK
Adjustment menu < DDIC > Preparation Completed GAMMA adjustment , SHADING adjustment ,
PREPARATION
(1) Connect the PC and Projector with a RS-232C cable and turn the Projector ON. (2) Boot the PSA software. (3) Click [Connect] on the menu bar and select [Auto Connect] in the pull-down menu.
Refer to Fig.1.
Fig.1
Fig.2 (4) When the connection is completed, press [DDIC]. The [DDIC Control] screen will appear. (5) Press the [Receive All] button located at the top right of the screen. (6) Click the [EVR] tab and then click [60P] as shown in Fig.2.
MEASUREMENT
(7) Press the [TEST] button on the remote control unit to display the grey scale of [R] (Color to be adjusted). (8) Using the [DDIC Control][EVR] tab, adjust [R_DELAY_CTL] (Refer to Fig.2) to allow the reflection to be minimum. (9) Perform the procedures in steps (7) and (8) for [G] and [B].
(10) When the procedure in step (9) is completed, click [50P] in the [EVR] tab and then click [Receive All]. (11) Perform the procedures in items (7), (8) and (9).
(6)Select 60p
(8)Adjust these parameters. (10)Select 50p
Fig.3
Adjust to minimize the reflection by monitoring
Enlarged
the left and right portions of the boundary.
Fig.4
(No.PA019)1-29
Page 30
4.4.7 FRAME adjustment
A
Instruments Signal generator REPLACING COMPONENTS Test point
z OPTICAL BLOCK
Adjustment menu < DDIC > Preparation Completed GAMMA adjustment , SHADING adjustment ,
PREPARATION
(1) Connect the PC and Projector with an RS-232C cable. Turn the Projector ON and boot the PSA software. (2) Click [Connect] on the Menu Bar and select [Auto Connect] in the pull-down menu.
Refer to Fig.1. (If [Connection failed] is shown, the connection is FAILED. If no message appears, the connection is successfully done.
Fig.1
(3) When the system is connected, press the [DDIC] button. This causes the [DDIC Control] screen to be displayed. Subsequent
works are to be performed on this screen. (4) Press the [Receive All] button at the top right of the screen. (5) Set [R_MUTE], [G_MUTE} and [B_MUTE] to ON with the [FPGA] tab. (6) Set Flat Field Level of R, G, and B to all [0]. (All black)
ADJUSTMENT
(1) Move the slider of [GK_R], [GK_G] and [GK_B] with the [EVR] tab to allow the picture frame to be darkened most. Refer to
Fig.2.
djust here
1-30 (No.PA019)
Fig.2
Page 31
SECTION 5
TROUBLESHOOTING
5.1 PROTECTIVE SENSOR AND PROTECTIVE SWITCH
In event of abnormal operation due to circuit or component failure, setting error or other reason, in order to prevent serious damage to the set and preserve the integrity of peripheral equipment, sensors and switches are provided for protective functions. Cooling is conducted at the same time a corresponding LED flashes (about 90 seconds). The LED indication with respect to the protective func­tion is described below.
5.1.1 Protective sensor
Type Monitor objective Location Operating point Function
Thermal sensor (Thermostat)
Thermal sensor (IC) Set interior
Thermal sensor (IC) Set exterior
Motor operation detection circuit
5.1.2 Protective switch
Type Monitor objective Location Operating point Function
Interlock switch Lamp cover Optical block (Lamp section) Switch open Control by CPU
Lamp unit Optical block (Lamp section) 140°C AC line (one side) open
MAIN PWB ASS'Y IC728 70°C Power off by main CPU (emergency mode)
(Lamp area)
MAIN PWB ASS'Y IC727 62°C Power off by main CPU (emergency mode)
(Filter area) Cooling fan Cooling fan interior Fan stop Power off by main CPU (emergency mode)
5.2 LED (INDICATOR) WARNING INDICATIONS
5.2.1 Led indication contents
If an abnormality occurs during operation (projection), the content of the problem can be determined from flashing LED indicators. When an LED indicates, operation (projection) automatically stops and the cool-down mode (about 90 seconds) is entered (except for No.1, No.3, No.4, No.5 and No.6), then the stand-by mode.
No. Flashing LED Flash time Warning cause (projector mode)
LAMP TEMP STAND BY OPERATE
1 zz0.5sec. Lamp not lighted cannot project
2 zz0.5sec. 3 ××0.5sec. Lamp terminal not contact
4 zz 0.5sec. Sub CPU circuit error 5 zz 0.25sec. Device drive circuit error 6 ×× 0.5sec. Video process circuit (decoder) error 7 ×× 0.25sec. Video system error after data initializing 8 z 0.5sec. Set interior abnormally hot
9 zz 0.5sec.
10 zzzz0.5sec. Set internal cooling fan stopped (fan locked) 11 z 0.5sec. Lamp use time exceeds 2000 hours
z : Flashing together × : Flashing alternately
Lamp extinguishes during projection Lamp use time ex­ceeds 2010 hours
Air intake temperature too high (exterior temperature abnormal)
(No.PA019)1-31
Page 32
5.2.2 Mearsures during abnormality
In event of the following be sure to disconnect the power cord from the AC outlet, and reset the projector mode.
No. Abnormality Mode Measure Mode Cause
1 Lamp dose not light Again supply power (press OPERATE button) OK Lamp lighting failure
NG Check lamp use dose not exceed 2000 hours YES Lamp use inhibited NG Replace lamp unit OK Lamp defective NG Replace LAMP BALLAST unit OK Igniter circuit faulty
2 Lamp extinguishes during
projection
Revise installation mode (protect from shock,
vibration, etc)
OK Installation mode (environment)
unfavorable
NG Replace lamp unit OK Lamp defective
Lamp use time exceeded Replace lamp and reset the lamp use time OK Lamp use inhibited
3 Sub CPU operation faulty Again supply power (press MAIN POWER
OK Circuit operating error
button)
NG Replace MAIN PWB ASS'Y OK Sub CPU failure
4 DD circuit operating faulty Again supply power (press OPERATE button) OK Circuit operating error
NG Replace MAIN PWB ASS'Y OK Device drive circuit failure
5 Decoder operation faulty Again supply power (press OPERATE button) OK Circuit operating error
NG Replace MAIN PWB ASS'Y OK Video process circuit failure
6 Video system data
Again supply power (press OPERATE button) OK Operating (loading) error
initializing error
7 Internal temperature
abnormally high
Avoid obstructing ventilation openings (intake
and exhaust)
OK Circuit error or other fault
NG Replace MAIN PWB ASS'Y OK Defective sensor and detection circuit
8 Out side temperature
abnormally high
Ambient temperature of the unit should be
mode into specification within the limits
OK Circuit error or other fault
NG Replace MAIN PWB ASS'Y OK Defective sensor and detection circuit
9 Cooling fan stopped Reinstall 713 connector OK Connector installation defective
NG Reinstall 705 connector OK Connector installation defective NG Reinstall 706 connector OK Connector installation defective NG Reinstall 707 connector OK Connector installation defective NG Reinstall 714 connector OK Connector installation defective NG Replace cooling fan OK Cooling fan defective
10 Confirmation of DVI
activation
Temporarily disconnect power from projector
and PC. After making sure that DVI cable has been properly connected, turn on power of
OK Improper connection of DVI cable
Wrong order of power on (Correct order : 1. Projector 2. PC )
projector and PC, in turn.
NG Confirm that output of DVI terminal at graphic
OK Improper setting of PC (DIV output)
board of PC has been set properly.
1-32 (No.PA019)
Page 33
5.3 ERROR LOG (SELF-DIAGONOSIS RECORD AND INDICATION)
5.3.1 Outline
By using the special setting and adjustment software, data related to abnormal operation (history) stored in the projector can be load. On the basis of contents "LED (INDICATOR) WARNING INDICATONS" set and lamp use time, internal and external temperature, and other data prior to the previous usage time can be viewed as a table.
z HOW TO LOAD THE DATA FROM UNIT
(1) Install the software in a personal computer and connect
by RS-232C IN terminal (use cross cable). (2) Set the projector to stand-by mode. (3) Start the setting and adjustment software. The main
menu shown in Fig.1 appears. (4) Click the [Error Log] button to show the screen indicated
in Fig.2. (5) Click the [Receive Log Data] button to display the history.
z ERROR LOG SCREEN ITEMS
Item Displayed contents
Error Detection Error event code (10 types) Wakeup Count Number of times operation mode reached System Time Total time in operation mode until present Lamp Time Total lamp lighted time until present Slave Deg (Out) External temperature detected by sensor dur-
ing error event
Sub Deg (In) Internal temperature detected by sensor dur-
ing error event
Click
Fig.1 Start screen (main menu)
Fig.2 <Error log> screen
5.3.2 Error code
Error cord Detected condition Indicated LED
E01 Lamp can not light during shift from stand-by to operation mode STAND BY + LAMP (Blinking) E02 Lamp use time exceeds 2000h LAMP (Blinking) E03 Inter IC bus communication error (ACK receive error) Absent E06 Lamp extinguishes during projection OPERATE + LAMP (Blinking) E07 Cooling fan stops (fan lock) All (4 LEDs Blinking) E08 Set internal temperature (lamp area) abnormally high (Exceeds 70°C) TEMP (Blinking) E09 Set internal temperature (ventilation intake openings) abnormally high (Exceeds 62°C) STAND BY + TEMP (Blinking) E10 Lamp use time exceeds 1900h LAMP(Light on) E11 Error in device drive circuit operation LAMP + TEMP (Blinking) E15 Come off lamp cover OPERATE + LAMP
(Alternately blinking)
E20 When the sleep time function operated and the lamp goes out Absent
5.3.3 Function
Button (item) Function Data process
Receive Receive data stored in projector and display < Error log > screen Projector to PC Reset Delete all data stored in projector (reset) Projector internal Clear Display Delete record (history) shown on < Error log > screen (delete computer side) PC internal Save Save record (history) shown on < Error log > screen to file PC internal Load Read record (history) stored in PC and display in < Error log > screen PC internal
(No.PA019)1-33
Page 34
VICTOR COMPANY OF JAPAN, LIMITED
ILA CENTER 12, 3-chome, Moriya-cho, kanagawa-ku, Yokohama, kanagawa-prefecture, 221-8528, Japan
(No.PA019)
Printed in Japan