JVC K3-R User Manual

K3 Series
1U Rack Mount A/B Switches
General Description
The K3 Series A/B Switching system provide up to 3 AB switches in a 1.75 in rack mount chassis for 19” Equipment cabinets. Each switch allows a common circuit (COM) to be switched to either of two circuits, designated A and B. The switches can be controlled locally with a front panel toggle switch and remotely by; contact closure, or thru a Serial port and Ethernet connection using Telnet, SNMP, or a Web browser.
Modular System
The K3 System consists of the K3 Chassis, Model K3-R and Power, Control and A/B Switch options. The following table illustrates the available K3 components available at the time of printing. Additional options may be available; contact Dataprobe.
Base Control
Power
A/B
SKU Model Description
1150100 K3-R K3 Chassis 1340062 C-AB-16-R IP and Serial Control Card, Individual Switch Control 1340065 C-AB-1-R IP Control Card, Gang Control 1340063 G-AB-1-R Gang Expansion or GPI Control 1930077 PS-R1-WRI Internal AC Power Supply 100-240VAC 1930078 PS-R1-48 Internal -48VDC Power Supply 1930079 PS-R1-224 Dual External 24VDC Power Supply. For use with External AC Supply 1930076 PS-WRI-4 External A/C Power Supply 1110100 AB-R-D25 25 Pin D Subminiature, all 25 pins supported
8 Wire Modular Jacks; All leads switched. Supports RJ48C, RJ48S, RJ45 and
1110101 AB-R-RJ8 1110102 AB-R-2RJ8 Same as above with two ganged switches.
1110103 AB-R-NET
1110104 AB-R-T50
1110105 AB-R-M34 1920028 AB-FP Blank Panel for unused A/B Slots. Required for FCC and CE marking
all 8 position modular jack specifications, up to16Mhz
8 Position, 8 Wire Modular Jacks; All leads switched; Supports 10/100/1G Ethernet Network specifications.
50 Pin Telco (Amphenol) connector. All 50 Leads Switched. Dual Height Switch must be in Slot 1
34 Pin M Type (V.35) connector. 23 leads switched. Dual Height Switch must be in Slot 1
K3_system_v070607e
Technical Support: 201-934-5111
Main: 201-934-9944
tech@dataprobe.com Website: dataprobe.com
K3 System Page 2
Installation & Operation
K3 Chassis
The K3 Chassis holds the Power, Control and A/B Switch modules for the K3 system. It installs in a standard 19” EIA equipment cabinet, requiring 1.75” (1U) of rack height. K3 systems are preconfigured and tested in the factory. All Control, Power and Switch modules are pre-installed.
Manual Switch Control
A front panel momentary toggle switch for each A/B Switch installed allows local manual control.
AB Switch Status Indication
Two front panel LED's for each A/B Switch installed indicates switch position A or B. Individual switch status can also be monitored thru the Network or Contact control interface.
Remote alarms or displays can be controlled by the status signal of each switch, which are provided as form C relay contacts when the Contact interface is installed.
Power Supply Status Indication
The K3 has two LED indicators that display the current status of two power supply sources. These are designated PS-1 and PS-2. LED ON Indicates the power supply source is connected.
PS-1 Internal Power Supply Module, or External Power Supply #1 PS-2 External Power Supply #2
K3 System Page 3
The K3 series supports both internal and external power supplies. Internal power modules are available to support worldwide A/C power, -48VDC and +24VDC power requirements. External power supplies provide redundancy either when used in pairs, or when combined with an internal module.
Power Supplies Modules
The K3 Series can be powered by several types of power sources using four types of power supply options; 90- 240VAC 50/60Hz Internal module, 90 -240 VAC External module, 48 VDC Internal module and 24 VDC direct.
Combinations of 1 internal + 1 external supply or 2 external supplies can be used for redundant power applications.
Dataprobe offers the following internal supply modules for the K-16 series:
193007 7 PS-R1-WRI Internal AC Power Supply 100-240VAC
193007 8 PS-R1-48 Internal -48VDC Power Supply
193007 9 PS-R1-224 Dual External 24VDC Power. For use with External AC Supply
Power Supply 1930077
Converts 110/ 220 /240 VAC to 24VDC Single Slot Redundant Capable
Input Power
Nominal : 120/240 VAC 50/60 Hz Range : 100 - 240 VAC Watts: 50 Fusing: 2 A
Environmental
Operating: 0 C - +65C
Physical
AC Input connector: IEC 320 (C14) on rear panel
Alarm / Expansion connector Contact Ratings: 1A @ 24VDC res.
: 9 pin d-Sub
ALARM
100 - 240 VAC
1.4A, 50-60 HZ
REFER TO MANUAL
!
Power Supply 1930078
Converts 48 VDC to 24VDC Single Slot Dual Redundant Capable
Input Power
Nominal : 48 VDC Range : 42 - 60 VDC Watts: 75 Fusing: 2.5 A
ALARM
INPUT 48VDC, 2A. MAX
Environmental
Operating: 0 C - +65C
Physical
DC Input Connector: Screw Terminal Mating Connector Supplied.
Alarm / Expansion connector: Contact Ratings: 1A @ 24VDC res.
9 pin d-Sub
K3 1RU AB Switch Page 4
Alarm Connector
Alarm Connection on each power supply provides status information on the condition of the supply.
9 Pin Dsubminiature
Pin 6 NO Pin 6 shorts to Pin 7 when the Power Supply is Non-Operational Pin 7 COM Pin 8 NC Pin 8 shorts to Pin 7 when the Power Supply is Operational
Power Access Panel 1930079
Provides for connection of two K-16-XPS Power Supplies
Input Power
Nominal : 24VDC Range : 20 – 30 VDC Fusing: 2 A Slo-Blo
Physical
DC Input Connector: Connector: Molex 41995 Mating Connector Kit # 1940164 Mating cable supplied with K-16-XPS
PS1 PS2
K3 24VDC External PS Panel Rear View
External Power Supplies 1930076
Power Input 100-120/200-240 50-60Hz IEC320 Male. Power Input cord supplied for North America.
Power Output +24VDC 4.5A, Connector Molex 41995.
6 5 4 3 2 1
1, 2 +24VDC 5, 6 GND 3, 4 N.C.
K3 1RU AB Switch Page 5
Control Modules
The K3 Series AB Switch System is available with three types of control modules; Network, Contact Closure, or Gang Control Expansion. One of three control options shown below will be installed in the chassis for remote control of the installed AB switch cards.
C-AB-16-R
C-AB-16-R provides remote control through In-Band and Out-of-Band operation thru Ethernet TCP/IP and Serial connections.
WEB
Telnet
SNMP
Serial
TCP Messaging
Through a web browser interface, you can access the control card, obtain current status information and operate the A/B Switches
Through a telnet client, you can access the control card, obtain current status information and operate the A/B Switches. This is also the method for setting configuration parameters of the card
The system can be managed by SNMP through standard management software. Dataprobe provides a private MIB.
The serial port on the C-AB-16-R provides direct terminal access or via modem. The A/B Cards are controlled either by a menu selection or by command line strings (escape code sequences). Menu selections are ideal for easy operator interface and the escape code sequences streamline automated control.
A direct TCP messaging protocol is supported for direct computer control of the A/B switching system
Installation
The Control interface is located in the lower middle section on the rear of the K3 chassis.
C-AB-16-R controller provides the following connections:
The 10base-T Ethernet. (C-AB-16-R
only) Network connection for access to the C-AB-16-R card.
Serial Port. RS-232 port for out-of­band access to the C-AB-16-R card.
Gang Expansion. RJ11 connection for connection to additional card nests for large gang switching applications.
External Power Input. Connection for external power supply K-16-XPS-R for single or dual redundant power. Mating Connector kit # 1940164
10base-T Ethernet
C-AB-16-R Rear View
Serial Port
Gang Expansion
Gang
External 24VDC Power Input (optional)
PS2
K3 1RU AB Switch Page 6
Serial Port
The Serial Port on the control card is a 9 pin male connector, configured as a DTE. The following pins are used. The following chart illustrates the pin out of the D9 connector and the connection required to an external modem with a D25 pinout.
D9 Pin Abbreviation Full Name
Pin 2 RD Receive Data Pin 3 Pin 3 TD Transmit Data Pin 2 Pin 5 SG Signal Ground Pin 7 Pin 9 RI Ring Indicator Pin 22
For connection directly to a terminal, a Null Modem cable is required.
C-AB-16-R
D9 Pin
Terminal
D9 Pin
Modem
D25 Pin
Pin 3 Pin 2 Pin 2 Pin 3 Pin 5 Pin 5
Configuration – C-AB-16-R
Configuration of the The C-AB-16-R involves the following steps:
Setting The C-AB-16-R 's IP Address
Setting additional configuration parameters using Telnet
Setting I/P Address
C-AB-16-R comes with factory installed IP address 192.168.1.254. In most cases this will need to
The be changed.
Consult your Network Administrator to determine the appropriate IP address. There are several methods to change the IP address.
ARP
Telnet
Serial Port
setip.exe program, available from Dataprobe’s web site
To set the IP address, the hardware (MAC) address must be known. This address is located on a label on on the C-AB-16-R printed circuit board. The syntax for the MAC address is: nn-nn-nn-nn-nn-nn
K3 1RU AB Switch Page 7
Setting the IP address using ARP
To set the IP address using ARP, connect the jack marked 10Base-T to your local Ethernet network and apply power to the unit. The computer used to set the IP address must be on the same physical network as the C-AB-16-R . ARP does not work across switched or routed networks.
Windows (98 and Later)
1. Open a DOS window.
2. Type the following command:
arp -s <IP Address> <MAC Address>
Where <IP Address> is the desired IP address (in dotted decimal) for the C-AB-16-R and the <MAC address> is the MAC Address of the C-AB-16-R . The MAC Address is located on a label on the rear panel of the card.
Example: arp -s 63.211.86.165 00-50-c2-05-01-c1 <enter>
3. Ping the C-AB-16-R to program the IP address into the C-AB-16-R .
Type: ping <IP Address> If the ping command returns “host not responding” 4 times then the address has not been programmed properly, or the IP or MAC Address is incorrect. In either case redo step 2. If the problem persists, contact the Dataprobe Tech Support Hot Line.
4. Delete the entry from the ARP cache by typing:
arp -d <IP Address>
5. Ping the C-AB-16-R to confirm that it has been programmed.
|--- new IP addr. ---| |------- MAC addr. ------|
If the card fails to respond, repeat steps 2-4 above. If the problem persists contact the Dataprobe support hotline.
Unix, Linux
Consult your systems administrator for information on setting an IP Address using ARP. The unit should be pinged after the IP Address has been set to confirm proper operation.
Setting IP Address with Telnet
For initial setup, the computer used must use the same network segment as the default IP Address, or current IP address. (192.168.1.xxx) If this is not the case, use one of the other methods. To connect to the C-AB-16-R using telnet, run your telnet client program (provided with your operating system) and connect to the IP address as set in step one above.
For Windows: Select Run…Telnet Connect…192.168.1.254 (or the current IP address)
As soon as you connect the following message will be displayed:
K-16 Ver 4.00
Please Enter The Password
Password >
The factory default password is: PASS
Loading...
+ 15 hidden pages