Cable TVs of Mid (X-Z, S1-S10)
Super (S11-S20) & Hyper (S21S41) bands receivable
32.5MHz(5.5MHz)
33.5MHz(4.5MHz)
31.5MHz (6.5MHz)
32.0MHz (6.0MHz)
PAL (4.43MHz),
SECAM(4.40625MHz/4.25MHz)
NTSC (3.58MHz / 4.43MHz)
/VT
CONTENT
AV-20N81
619mm×458mm×488mm518mm×391.5mm×403mm
19kg13kg
Visible size: 48cm measured
diagonally
26.5kV±1.0kV(at zero beam
current)
/VT
AV-16N81
Visible size: 38c m measured
diagonally
23.0kV±1.0kV(at zero beam
current)
/AV-16N81G
/VT
/VT
Power Input
Power Consumption
Speaker
Audio Output
Aerial Input Terminal
Input
Output
Remote Control Unit
Rated VoltageAC110~240V, 50 / 60Hz
Operated VoltageAC90~260V, 50 / 60Hz
110W (Max) / 78W (Avg) 89W (Max) / 67W (Avg)
5cm×12 cm, Oval type×25cm
5W +5W (Playb ack Ster eo)
75Ω Unbalanced
Video1V(p-p), 75Ω (Front / Rear)
500mV(r ms) (-4dBs), High
Audio
Video1V(p-p), 75
Audio
impedance,
RCA×2 (Front / Rear)
Ω
500mV(r ms) (-4dBs), Low
impedance,
RCA×1
RM-C378
(Battery size : AA / R06 / UM-3
2)
×
Design and specifications are subject to change without notice.
9 cm, Oval type×2
×
2
No. 51902
A
A
A
A
SAFETY PRECAUTIONS
V-21D81
V-20N81
V-16N81
V-16N81G
1. The design of this product cont ains special hardware, many
circuits and components specially for safety purposes. For
continued protection, no changes should be made to the original
design unless authorized in writing by the manufacturer.
Replacement parts must be identic al to those used in the original
circuits. Service should be performed by qualified personnel
only.
2. Alterations of the design or circuitry of the products should not be
made. Any design alterations or additions will void the
manufacturer's warranty and will further relieve the manufacturer
of responsibility for personal injury or property damage resulting
theref rom.
3. Many electric al and mechanical parts in the products have
special safety-related characteristics. These characteristics are
often not evident from visual inspection nor can the protection
afforded by them necessarily be obtained by using replacement
components rated for higher voltage, wattage, etc. Replacement
parts which have these special safety characteristics are
identified in the parts list of Service manual.
components having such features are identified by shading
on the schematics and by (
manual.
have the s ame safety characteristics as the recommended
replacement part shown in the parts list of Service manual may
cause shock, fire, or other hazards.
The us e of a substitute replacement which does not
) on the parts list in Service
Electrical
4.
Don't short between the LIVE side ground and ISOLATED
(NEUTRAL) side ground or EARTH side ground when
repairing.
Some model's power circuit is partly different in the GND. The
differenc e of the GND is shown by the LIVE : () side GND, the
ISOLATED(NEUTRAL) : () side GND and EARTH : () side
GND. Don't short between the LIVE side GND and
ISOLATED(NEUTRAL) side GND or EARTH side GND and
never meas ure with a measuring apparatus (oscilloscope etc.)
the LIVE side GND and ISOLATED(NEUTRAL) side GND or
EARTH side GND at the same time.
If above note will not be kept, a fuse or any parts will be broken.
5. If any repair has been made to the chassis, it is recommended
that the B1 setting should be checked or adjusted (See
ADJUSTMENT OF B1 POWER SUPPLY).
6. The high voltage applied to the pictur e tube must conform with
that specified in Service manual. Excessive high voltage can
cause an incr ease in X-Ray emission, arcing and possible
component damage, therefore operation under excessive high
voltage conditions should be kept to a minimum, or should be
prevented. If severe arcing occurs, remove the AC power
immediately and det ermine the caus e by visual inspection
(incorrect installation, cr acked or melted high voltage harness,
poor soldering, etc.). To maintain the proper minimum level of
soft X-Ray emission, components in the high volt age circuitry
including the picture tube must be the exact replacements or
alternatives approved by the manuf acturer of the complete
product.
7. Do not check high voltage by dr awing an arc. Use a high voltage
meter or a high voltage probe with a VTVM. Discharge the
picture tube before attempting meter connection, by connecting
a clip lead to the ground frame and connecting the other end of
the lead through a 10k: 2W resistor to the anode button.
8. W hen service is required, observe the original lead dress. Extra
precaution should be given to assure correct lead dress in the
high voltage circuit area. W here a short circuit has occurred,
those components that indicat e evidenc e of overheating should
be replaced. Always us e the manufacturer's replacement
components.
9.
Isolation Check
(Safety for Electrical Shock Hazard)
After re-assembling the product, always perf orm an isolation
check on the exposed metal parts of the cabinet (antenna
terminals, video/audio input and output terminals, Control knobs,
metal c abinet, screwheads, earphone jack, c ontrol shafts, etc.)
to be sure the product is safe to operate without danger of
electr ic al shoc k.
(1)
Dielectric Strength Test
The isolation between the AC primary circuit and all metal parts
exposed to the user, particularly any expos ed metal part having a
return path to the chass is should withstand a voltage of 3000V
AC (r.m.s.) for a period of one second.
(. . . . Withstand a voltage of 1100V AC (r.m.s.) to an applianc e
rated up to 120V, and 3000V AC (r.m.s.) to an appliance rated
200V or more, for a period of one second.)
This method of test requires a test equipment not gener ally found
in the s ervice trade.
(2)
Leakage Current Check
Plug the AC line cord directly into the AC outlet (do not use a line
isolation transformer dur ing this check.). Using a " Leakage
Current T ester", measure the leakage current from each exposed
metal part of the cabinet, particularly any exposed metal part
having a return path to the chassis, to a known good earth
ground (water pipe, etc.). Any leakage c urrent must not exceed
0.5mA AC (r.m.s.).
However, in tr opical area, this must not exceed 0.2mA AC
(r.m.s.).
Alternate Check M ethod
zzzz
Plug the AC line cord directly into the AC outlet (do not use a line
isolation transformer during this check. ). Use an AC voltmeter
having 1000 ohms per volt or more sensitivity in the f ollowing
manner. Connect a 1500: 10W resistor paralleled by a 0.15PF
AC-type capacitor between an expos ed metal part and a known
good earth ground (water pipe, etc.). Measure the AC voltage
across the resistor with the AC voltmeter. Move the resistor
connection to each exposed metal part, particularly any exposed
metal part having a return path to the chassis, and measure the
AC voltage across the resist or. Now, reverse the plug in the AC
outlet and repeat each measurement. Any voltage meas ured
must not exceed 0.75V AC (r.m.s.). This corresponds to 0.5mA
AC (r.m.s.).
However, in tr opical area, this must not exc eed 0.3V AC (r.m.s.).
This corresponds to 0.2mA AC (r.m.s.).
AC VOLTMETER
0.15μF AC-T YPE
1500
GOOD EARTH GROUND
:
(HAVING 1000
OR MORE SENSITIVITY)
10W
/V,
:
PLACE THIS PROBE
ON EACH EXPOSED
METAL PART
No.51902
3
A
V-21D81
A
A
A
V-20N81
V-16N81
V-16N81G
FEATURES
New chassis design enables use of an interactive on-screen control.
z
Wide range voltage (R ated 110V~240V,Operated 90V~260V) AC power input.
z
With AUDIO / VIDEO INPUT & OUTPUT terminal.
z
MUTING button can reduce the audio level to zero instantly.
z
Functional remote control to operate TV set (for channel select, volume control, power ON/OFF, etc.) from a distance.
z
2
C bus control utilizes single chip ICs for IF, V/C, VSM PRESET.
I
z
By means of AUTO PROGRAM, the TV stations can be s elected automatically and the TV channels can als o be rearranged automatically.
z
Built-in AI ECO (ECONOMY, ECO LOGY) sensor.
z
In accordance with the brightness in a room, the brightness and / or contrast of the picture can be adjust ed automatically to make the
optimum picture which is easy on the eye.
Built - in ON TIMER, RETURN + & CHILD LOCK.
z
SYSTEM BLOCK DIAGRAM
IC702
MEMORY
SCL2/SDA2
IC701
MICRO
COMPUTER
IC201
VIDEO/CHROMA
DECORDER
SCL1/SDA1
TU001
TUNER
4
No. 51902
A
A
A
A
FUNCTIONS
A
FRONT PANEL
■
( AV-21D81 )
V-20N81
AV-16N81/AV-16N81G
MENU buttons
①
CHANNEL -/+ buttons
②
VOLUME -/+ buttons
③
ECO sensor
④
REMOTE CONTROL sensor
⑤
ON TIMER lamp
⑥
POWER lamp
⑦
MAIN POWER button
⑧
A/V INPUT terminal
⑨
V-21D81
V-20N81
V-16N81
V-16N81G
REAR TERMINAL
■
①
②③④⑤ ⑦⑧⑨①⑥
②
④
⑤
⑥
⑦
③
AV-20N81
AV-16N81/AV-16N81G
ANT Terminal
①
VIDEO INPUT Terminal
②
VIDEO OUTPUT Terminal
③
AUDIO LEFT INPUT Terminal
④
AUDIO RIGHT INPUT Terminal
⑤
AUDIO LEFT OUTPUT Terminal
⑥
AUDIO RIGHT OUTPUT Terminal
⑦
No. 51902
5
A
V-21D81
A
A
A
V-20N81
V-16N81
V-16N81G
REMOTE CONTROL UNIT(RM-C378)
■
DISPLAY key
①
MENU key
②
MENU ▲/▼ key
MENU -/+ key
LIVE SPATIAL key
③
CHANNEL -/+ key
④
SOUND SYSTEM key
⑤
COLOUR SYSTEM key
⑥
TV / VIDEO key
⑦
PICTURE MODE key
⑧
CHANNEL SCAN key
⑨
RETURN+ key
⑩
POWER key
⑪
VOLUME -/+key
⑫
MUTING key
⑬
NUMBER (CH.) key
⑭
⑮ -/--
⑯
⑰
⑱
key
OFF TIMER key
ECO SENSOR key
PICTURE BOOSTER key
6
No. 51902
A
A
A
A
MAIN DIFFERENCE LIST
V-21D81
V-20N81
V-16N81
V-16N81G
Part Name
MAIN PW BSCL-1299A-CKSCL-1295A-CKSCL-1296A-CK
CRT SOCKET PWBSCL-3012A-CKSCL-3013A-CK
FRONT CABINETLC11129- 010A-HKLC10438- 026A-HKGG10021-004AGG10021-005A
POWER KNOBGG30019-001B-HLC30663- 003A-HLC30616- 004A-H
CONTROL KNOBGG20006-001A-HLC20318-003A-HLC20292-004A-H