B Close the gas valve.
B Open the windows.
B Do not turn on any electrical switch.
B Extinguish any fire.
B Go to a different location and call the gas supplier or
an authorised technician.
If you smell combustion gases:
B Turn off the heater.
B Open doors and windows.
B Notify a gas fitter.
Assembly, modifications
B The assembly and modifications during the
installation of the heater can only be performed by an
authorised installer.
B Do not modify the pipes which conduct combustion
gases.
B Do not close or reduce air circulation vents.
Explanation of symbology
The safety instructions which appear in
the text have a grey background and are
identified in the margin by a triangle
surrounding an exclamation mark.
The warnings used indicate the degree of risk in case
the precautionary measures are not complied with.
• Caution is used to indicate the risk of minor material
damage.
• Warning is used to indicate the risk of minor personal
injuries or more severe material damage.
• Danger is used to indicate the risk of severe personal
injuries which, in certain cases, may result in death.
Indications in the text are identified by the
symbol in the margin.
i
The beginning and end of the text are
indicated by a horizontal line.
The instructions contain important information which
does not pose a risk to people or the heater.
Maintenance
B The user must periodically maintain and check the
heater.
B The user is responsible for safety and environmental
protection during installation.
B The heater must be serviced annually.
B Only original spare parts are allowed to be used.
Explosive and highly inflammable material
B Do not store or use inflammable material (paper,
solvents, paints, etc) near the heater.
Combustion air and surrounding air
B To avoid corrosion, the combustion air and
surrounding air must be free from harmful
substances (e.g. halogenated hydrocarbons which
contain chlorine and fluorine compounds).
Information to the client
B Inform the client about how to operated and handle
the heater.
B Inform the client that no independent modifications
are permitted.
6 720 607 WRDG
3
Technical Characteristics and Dimensions
1Technical Characteristics and Dimensions
1.1General Description
0464
ModelWRD 11/14/18 -2 G...
CategoryII
TypeB
2H3+
11BS
Tab. 1
1.2Explanation of Model Code
WRD 11-2G 2331S....
WRD 14-2G 2331S....
WRD 18-2G 2331S....
Tab. 2
WWater gas heater
RProportional power adjustment
DDigital display
11Capacity (l/min)
-2Version 2
GElectronic ignition powered by hydrogenerator
23Indicator number of natural gas H
31Indicator number of LPG
S...Country code
• Temperature sensor to monitor the water
temperature at the heater output
• Great savings in comparison with conventional
heaters, due to the possibility of power adjustment
and no permanent pilot flame
• Natural gas/LPG burner
• Semi-permanent pilot burner which only functions
during the period between the opening of the water
valve and the ignition of the main burner
• Heat exchanger without tin/lead covering
• Water valve in fibreglass-reinforced polyamide,
100% recyclable
• Automatic adjustment of the water flow by means of
a device which permits a constant flow to be
maintained in spite of variable pressure supplies
• Gas flow adjustment proportional to the water flow to
maintain a constant high temperature.
• Safety devices:
– Ionisation probe to check for accidental extinction
of the burner flame
– Flue gas safety device which turns off the heater in
case of inadequate combusted gas evacuation
conditions
– Temperature limiter which prevents overheating of
the heat exchanger.
1.5Special accessories
• Conversion kit from natural gas to butane/propane
and vice-versa.
1.3Accessories (Included with Appliance)
• Gas heater
• Attachment elements
• Connection elements
• Heater documentation.
1.4Description of the heater
Operating convenience, as the heater is ready to
operate by simply pressing a switch.
• Heater for wall-mounting
• Ignition by electronic device triggered when the
water valve opens
• Hydrodynamic generator which produces sufficient
energy to ignite and control the heater.
• Gauge to display temperature, burner operation and
malfunctions
4
6 720 607 WRDG
1.6Dimensions
Technical Characteristics and Dimensions
Fig. 1
4Heat exchanger
5Burner
10Temperature/volume selector
20Gas connection
23Ignition unit
26Power selector
34LED - Burner status check
Dimensions
(mm)
ABCDEFG
35Switch/LED - Low water pressure indicator
36Front cover
37Opening for mounting on the wall
38Connection collar to the combustion gases pipe
39Flue with non-return device
40Gas valve
42Digital display
H (Ø)
Natural gasLPG
WRD11G310580228112,546360253/4”1/2”
WRD14G350655228132,551095303/4”1/2”
WRD18G425655334132,554065303/4”1/2”
Tab. 3 Dimensions
6 720 607 WRDG
5
Technical Characteristics and Dimensions
1.7Functional diagram of the heater
Fig. 2Functional diagram
1Pilot burner
2Spark plug
3Ionisation probe
4Heat exchanger
5Main burner
6Injector
7aScrew for measurement of pressure in burner
7bScrew for measurement of input pressure
8Slow ignition valve
9Venturi
10Temperature/volume selector
11Water valve
12Command cone
13Water flow regulator
14Water filter
16Cold water pipe
17Diaphragm
18Main gas valve
19Maximum gas adjusting screw
6
20Gas supply pipe
21Gas filter
22Hot water pipe
23Ignition unit
25Servo valve
26Power selector
27Gas valve
28Pilot valve
29Pilot injector
30Pilot gas pipe
31Temperature limiter
32Flue gas safety device
41Temperature sensor
50Hydrogenerator
6 720 607 WRDG
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.