Page 2
Factory-Default Settings for Initial Configuration:
Factory-Default Settings for Security Policies:
Factory-Default Settings for NAT Rule:
NOTE: Source NAT translates the source address for packets coming from any number
of hosts on a private network to one public IP address.
Task 1: Connect the Power Cable and a Power Source
Connect the power cable to the device and a power source. We recommend using a
surge protector. Note the following indications:
POWER LED (green): The device is receiving power.
STATUS LED (green): The device is operating normally.
ALARM LED (yellow): The device is operating normally, and a rescue configuration
might not have been set. This is not a panic condition.
NOTE: After a rescue configuration has been set, a yellow ALARM LED indicates a
minor alarm, and a solid red ALARM LED indicates a major problem on the services
gateway.
mPIM LED (off): The Mini-Physical Interface Module (Mini-PIM) is not present or is
not detected by the device. If this LED is green and steadily on, it indicates that the
Mini-PIM is functioning normally.
NOTE: You must allow the device between 5 and 7 minutes to boot after you power it on.
Wait until the STATUS LED is solid green before proceeding to the next task.
Task 2: Connect the Management Device
Use one of the following methods to connect the management device to the services
gateway:
Method 1: Connect an RJ-45 cable (Ethernet cable) from any one port from 0/1
through 0/15 (interfaces ge-0/0/1 and ge-0/0/15) on the front panel to the Ethernet
port on the management device (workstation or laptop). We recommend this
connection method. If you are using this method to connect, proceed to Task 3.
Method 2 : Connect an RJ-45 cable (Ethernet cable) from the port labeled
CONSOLE to the supplied DB-9 adapter, which then connects to the serial port on
the management device (serial port settings: 9600 8-N-1-N).
If you are using this method to connect, proceed with the CLI configuration
instructions in the Getting Started Guide for the Branch SRX Series at
http://www.juniper.net/techpubs/en_US/release-independent/junos/
information-products/pathway-pages/srx-series/product/index.html.
Connecting a Management Device
Task 3: Ensure That the Management Device Acquires an IP Address
After you connect the management device to the services gateway, the DHCP server
process on the services gateway automatically assigns an IP address to the
management device. Ensure that the management device acquires an IP address on the
192.168.1.0/24 subnetwork (other than 192.168.1.1) from the services gateway.
NOTE: The services gateway functions as a DHCP server and assigns an IP address to
the management device.
If an IP address is not assigned to the management device, manually configure an
IP address on the 192.168.1.0/24 subnetwork. Do not assign 192.168.1.1 as the IP
address to the management device because this IP address is assigned to the
services gateway. By default, the DHCP server is enabled on the Layer 3 VLAN
interface, (IRB) vlan.0 (ge-0/0/1 to ge-0/0/15), which is configured with an IP
address of 192.168.1.1/24.
When an SRX240 Services Gateway is powered on for the first time, it boots using
the factory-default configuration.
Port Label Interface Security Zones DHCP State IP Address
0/0 ge-0/0/0 untrust client unassigned
0/1 to 0/15 ge-0/0/1 to
ge-0/0/15
trust server 192.168.1.1/24
Source Zone Destination Zone Policy Action
trust untrust permit
trust trust permit
untrust trust deny
Source Zone Destination Zone Policy Action
trust untrust source NAT to untrust zone
interface
g037511