JUMO MAERA S25
Level probe
Applications
Level and level measurements
•In rainwater cisterns
•In gray water recycling
•Heating oil and diesel oil tanks
•In AUS32 (known in Europe as "AdBlue®", "DEF" in North America, or "ARLA 32" in Brazil)
Brief description
The JUMO MAERA S25 level probe is used for the continuous hydrostatic level measurement of
liquids. Filling heights between 2.50 mWS and 10 mWS (water column) can be achieved in ventilated tanks.
When the level probe is immersed into a liquid, a liquid column emerges above the probe. The
liquid column increases as the probe is immersed deeper into the liquid and creates a hydrostatic
pressure on the measuring system by the force of its weight. The measured pressure is transferred as a standard signal. The signal is linearly proportional to the rising liquid column.
Any variations in air pressure are automatically compensated for using a protective hose and the
surrounding pressure is therefore taken into account.
Further information on our level probes from the JUMO MAERA series can be found in the brochure "Level probes – Hydrostatic level and level measurement" in the documentation.
1
Page 1/10Data Sheet 401015
Customer benefits
•Economic
The standardized, constructive design and constant optimization of the production process
result in an excellent price-performance ratio of the level probe.
•Process-reliable
The core of the level probe is a piezoresistive measuring cell, which features high overload
resistance and is particularly safe, reliable, and temperature resistant. Each level probe is
tested in a fully automated measuring and calibration facility to ensure consistently high
product quality. A reverse-polarity protection mechanism protects the measuring instrument
against damage, ensuring maximum safety during startup.
1
These recommendations are based on many years of experience; however, in individual cases they may not be fully applicable. We would be happy to provide further information, including regarding additional applications.
Type 401015 with process connection 707
Special features
•Level probe for continual level measurement in liquids
•Measuring ranges: 250 mbar to 1 bar
(2.5 to 10 mWS)
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax:+44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax:+1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
Environmental influences
Admissible temperatures
Medium0 to 50 °C
The device must not freeze in the medium!
A restriction may be required depending on the medium.
Storage-20 to +80 °C, dry
Electromagnetic compatibility
Interference emission
Interference immunity
Protection type
a
According to EN 61326-1
b
According to EN 61326-2-3
c
According to EN 60529
a
b
c
Class B
Industrial requirements
IP68, submersible to 20 m
Measuring range and accuracy
Page 3/10Data Sheet 401015
Measuring rangeLinearity
bar% MSP% MSP% MSP% MSP
a
Accuracy atLong-term
20 °C
c
0to50°C
d
stability
b
Overload
capability
Burst
pressure
barbar
per year
0 to 0.25 bar relative pressure0.30.51≤ 0.30.751
0 to 0.4 bar relative pressure0.30.511.21.6
0 to 0.6 bar relative pressure0.30.511.82.4
0 to 1 bar relative pressure0.30.5134
a
Linearity according to limit point setting
b
Reference conditions EN 61298-1
c
Includes: linearity, hysteresis, repeatability, deviation from measuring range start (offset), and measuring range end
d
Includes: linearity, hysteresis, repeatability, deviation from measuring range start (offset) and measuring range end, thermal influences on measuring range start (offset), and measuring span
Auxiliary power
Voltage supply U
4 to 20 mA, two-wire (output 405)DC 10 to 30 V, nominal voltage DC 24 V
DC 0.5 to 4.5 V, three-wire (output 412)DC 5 V
DC 0 to 10 V, three-wire (output 415)DC 11.5 to 30 V, nominal voltage DC24V
DC 1 to 5 V, three-wire (output 418)DC 10 to 30 V, nominal voltage DC 24 V
DC 1 to 6 V, three-wire (output 420)DC 10 to 30 V, nominal voltage DC 24 V
a
The voltage peaks must not exceed or fall below the specified voltage supply values!
Reverse voltage protectionYes (except output 412)
Max. current consumption25 mA
Electrical circuitSELV
RequirementsThe device must be equipped with an electrical circuit that meets the requirements of EN 61010-
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax:+44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax:+1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
Electrical connection
For this construction, a stranded PVC cable is encased in an application-oriented protective hose made from either PE or PA.
To prevent moisture penetrating into the protective hose, in this case the pressure equalization hose, the delivery includes a hose end piece with
the fitting materials.
Protective hose
MaterialPE, PA
a
ColorNatural
Outer diameter8 mm
Bending radiusApprox. 120 mm
It is vital to take into account that if the protective hose is kinked or pinched, this will prevent ambient pressure compensation.
Admissible medium temperatures0 to 50 °C (depending on the medium and the level probe)
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax:+44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax:+1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
Connection diagram
The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection, only use
the installation instructions or the operating manual. The knowledge and the correct technical compliance with the safety information and warnings
contained in these documents are mandatory for mounting, electrical connection, and startup as well as for safety during operation.
ConnectionTerminal assignment
a
Cable
4 to 20 mA, two-wire (output 405)
Voltage supply DC 10 to 30 V,
Rated voltage supply DC 24 V
DC 0.5 to 4.5 V ratiometric (output 412)
Voltage supply DC 5 V,
Rated voltage supply DC 5 V
DC 0 to 10 V, three-wire (output 415)
Voltage supply DC 11.5 to 30 V,
Rated voltage supply DC 24 V
DC 1 to 5 V, three-wire (output 418)
DC 1 to 6 V, three-wire (output 420)
Voltage supply DC 10 to 30 V,
Rated voltage supply DC 24 V
a
For cable specifications, see installation instructions B 401015.4, chapter 6 "Installation and mounting".
b
The voltage peaks must not exceed or fall below the specified voltage supply values!
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax:+44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax:+1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
Accessories
ItemDescriptionPart no.
Terminal head for pressure compensationThe terminal head is only suitable for application in the level probe
Tank cover mounting00602743
Wall mounting00602744
variant JUMO MAERA S25 (type 401015).
It is used to mount the level probes cost-effectively and in the best
possible way. Protection type IP 67 is achieved.
By using it locally with the tank mounting or wall mounting versions, a
rapid pressure compensation can be achieved and the length of the
special cable can be minimized. The costs are thereby reduced as an
electric standard cable can be used as the outgoing cable from the terminal head.
Furthermore, the direction (for example to the control cabinet) can be
individually specified.
Page 10/10Data Sheet 401015
Scope of delivery
ItemDescription
Hose end pieceWith this device, a standard cable is encased in a protective hose suitable for the application. The
hose end piece prevents the hose, which is used as a pressure compensation hose, from being
cut off or bent, for example when being routed through a wall. The hose end piece may be used
for example in routing through walls in masonry, clamp or cutting ring fittings in a tank, or cable
glands in a control cabinet.
The hose end piece is supplied with the device.
V5.00/EN/00534318