JUMO 902435 User Manual

Page 1
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
Push-in RTD temperature probe for heat meter with connection cable for immersion sleeves (type PS/PL)
For temperatures from 0 to 180 °CApproval for heat meter MID and domestic approval
as exchangeable temperature probes
Meets the requirements as per DIN EN 1434, AGFW FW202 and FW211Approval for cold meter and cold / heat meter combinationsPaired and calibrated as per the German calibration regulationsProduction certified as per module D of the MID (CE and metrology sign)Adapted accessoried for installation (data and price sheet 902440)
Heat meter RTD temperature probes are used for temperature measurement in closed-loop pipe systems. Thanks to the installation in thermowells with tolerance on fit for optimum thermal coupling, the system need no longer be discharged at the time of the regular exchange once the certification period has elapsed.
The temperature probes are approved in accordance with the EU directive 2004/22/EC (MID) as well as according to the German calibration regulations (domestic approval). The tempera­ture probes are available paired and calibrated. The state-approved test body for heat KF2 is responsible for this purpose. Moreover, the production is certified according to module D of MID, and the temperature probes are also available with the CE and metrology sign.
Data sheet 902435 Page 1/8
Note:
In Germany, temperature probes, type PS, with MID approval may no longer be installed in new installations smaller than DN 25 pipe systems (4th. amendment of the Calibration Regulations).
Technical Data
Process connection Push-in RTD temperature probe for thermowells (immersion sleeves) Connection Wire end ferrules Connection cable PVC, PUR, TPE, Silicone; unshielded or shielded
Thermowell Type PS: stainless steel Ø 5.0 mm, Ø 5.2 mm or Ø 6.0 mm
Measuring insert Platinum temperature probe as per DIN EN 60751
Temperature Type PS: 0 to 150 °C
Temperature difference Type PS: 3 to 150 K
Minimum immersion depth Type PS: > 15 mm
Fitting length Type PS: 45 to 85 mm
Response behavior Type PS: t
Ambient conditions Climatic 0 to 70 °C
Accessories For the thermowell, refer to the data and price sheet 902440
2010-09-08/00530105
For the max. connection cable lengths, refer to the table on the following page
Type PL: stainless steel Ø 6.0 mm Thermowell with tolerance to fit for thermowells
Rated value: Pt100, Pt500, Pt1000; class B Connection: 2-wire/4-wire circuit
Type PL: 0 to 180 °C
Type PL: 3 to 180 K
Type PL: 30 mm
Type PL: 85 to 450 mm
= 15 s (installed in thermowell)
Type PL: t
Protection class IP65 Electromagnetic E1 Mechanical M3
0.5
= 12 s (installed in thermowell)
0.5
Page 2
Data sheet 902435 Page 2/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
Cable cross-section Max. connection cable length AL
for Pt100
0.22 mm
0.34 mm
0.50 mm
2
2
2
2500 mm 12500 mm 25000 mm 3500 mm 17500 mm 35000 mm 5000 mm 25000 mm 50000 mm
Max. connection cable length AL for Pt500
Max. connection cable length AL for Pt1000
Note:
Also take into account a possible connection cable length limitation due to the design approval of the arithmetic unit/counter. For 4-wire circuit, the max. connection cable lengths are limited due to the requirements of the arithmetic unit/counter.
Approval overview
Version Basic type Approval
Type Number
Figure: PS 90.276-F40 (PS)
902435/05 (PS)
902435/10 (PS) Domestic (Germany) 22.30/99.10 (105 °C) 902435/11 (PS) 902435/50 (PS) Domestic (Germany) 22.30/02.03 (150 °C) 902435/51 (PS) 902435/10 (PS)
902435/11 (PS) 902435/50 (PS)
902435/51 (PS) 902438/50 (PS) Module B as per MID
Figure: PL 90.276-F80 (PL) Domestic (Germany) 22.30/91.05 (180 °C)
902435/30 (PL) Domestic (Germany)
902438/30 (PL) Module B as per MID 902465/30 (PL) Domestic (Germany; Cold) 22.77/09.01 (150 °C)
Domestic (Germany) 22.30/89.07 (Pt100) (150 °C)
22.30/89.08 (Pt500) (150 °C)
22.30/89.09 (Pt1000) (150 °C)
Domestic (Germany)
22.70/99.10 (105 °C)
as per DIN EN 1434 Domestic (Germany)
22.70/02.03 (150 °C)
as per DIN EN 1434
1
A0445-2112-2007 (150 °C)
22.70/00.01 (180 °C)
as per DIN EN 1434
1
DE-06-MI004-PTB011 (180 °C)
1
MID = Measuring Instruments Directive, European measuring instrument directive 2004/22/EC
2010-09-08/00530105
Page 3
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
Dimensions
D
EL AL
D
15 ALEL
Data sheet 902435 Page 3/8
Basic type 90.276-F40, 902435/05 (PS) Basic type 902435/10 (PS) Basic type 902435/50 (PS) Basic type 902438/50 (PS)
Basic type 90.276-F80 (PL) Basic type 902435/30 (PL) Basic type 902438/30 (PL) Basic type 902465/30 (PL)
2010-09-08/00530105
Page 4
Data sheet 902435 Page 4/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
D
EL AL
D
EL AL
Order details: Heat meter RTD temperature probe with connection cable,
PTB approved 22.30/89.07 (.08; .09), 22.30/99.10, 22.70/99.10, 22.30/02.03, 22.70/02.03
(1) Basic type
902435/10
Push-in RTD temperature probe (PS) T Thermowell made of stainless steel, for installation in a thermowell
902435/05
(90.276-F40)
902435/50
Push-in RTD temperature probe (PS) T Thermowell made of stainless steel, for installation in a thermowell
(2) Operating temperature in °C
x x 815 0 to 105 °C/PVC 105, PUR (only in 2-wire circuit)
x 824 0 to 150 °C/Silicone
(3) Measuring insert
x x 1003 1x Pt100 in 2-wire circuit x x 1004 1x Pt500 in 2-wire circuit x x 1005 1x Pt1000 in 2-wire circuit
x 1011 1x Pt100 in 4-wire circuit x 1012 1x Pt500 in 4-wire circuit x 1013 1x Pt1000 in 4-wire circuit
(4) Tolerance class as per DIN EN 60751
xx 1 Class B (standard)
x2Class A x3Class AA (1/3 DIN B)
(5) Thermowell diameter D in mm
xx 5 Ø5mm x x 5.2 Ø 5.2 mm xx 6 Ø6mm
(6) Fitting length EL in mm (45 to 85 mm)
x x 45 45 mm (only for Ø 5 mm and Ø 5.2 mm) x x 50 50 mm (only for Ø 6 mm) x x 60 60 mm (only for Ø 6 mm) x x ... Specifications in plain text
(7) Cable termination
x x 04 Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit) x x 11 Ferrules as per DIN 46228 Part 4 (standard)
(8) Connection cable length AL in mm (> 500 mm)
x x 1500 1500 mm x x 2500 2500 mm (Standard) x x ... Specifications in plain text (500 mm steps)
(9) Extra codes
x x 000 None x x 317 Shielded connection cable x x 340 Version paired as per DIN EN 1434 x x 341 Version paired as per DIN EN 1434 and calibrated
2
= 105 °C,
max.
= 150 °C,
max.
3
Order code -------/,... Order example 902435/10 - 815 - 1003 - 1 - 5 - 45 - 11 - 2500 / 341
Note:
For the thermowell, refer to the data and price sheet 902440
1 2 3
2010-09-08/00530105
(1) (2) (3) (4) (5) (6) (7) (8) (9)
List extra codes in sequence, separated by commas. Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock. Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
1
Page 5
Data sheet 902435 Page 5/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
D
EL AL
Order details: Heat meter RTD temperature probe with connection cable,
PTB approved 22.30/91.05, 22.70/00.01
(1) Basic type
902435/30
x 815 0 to 105 °C/PVC 105 (only in 2-wire circuit) x 824 0 to 150 °C/Silicone x 830 0 to 180 °C/Silicone
x 1003 1x Pt100 in 2-wire circuit x 1004 1x Pt500 in 2-wire circuit x 1005 1x Pt1000 in 2-wire circuit x 1011 1x Pt100 in 4-wire circuit x 1012 1x Pt500 in 4-wire circuit x 1013 1x Pt1000 in 4-wire circuit
x 1 Class B (standard) x 2 Class A x 3 Class AA (1/3 DIN B)
x6Ø6mm
x 105 105 mm x 140 140 mm x 230 230 mm x ... Specifications in plain text
x 04 Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit) x 11 Ferrules as per DIN 46228 Part 4 (standard)
x 1500 1500 mm x 2500 2500 mm (Standard) x ... Specifications in plain text (500 mm steps, max. connection cable length, see table)
x 000 None x 317 Shielded connection cable x 340 Version paired as per DIN EN 1434 x 341 Version paired as per DIN EN 1434 and calibrated
Push-in RTD temperature probe for installation in a thermowell (PL), Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (85 to 400 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2, 3
Order code - - - - - - - / ,... Order example 902435/30 - 830 - 1003 - 1 - 6 - 140 - 11 - 2500 / 341
Note:
For the thermowell, refer to the data and price sheet 902440
1 2 3
2010-09-08/00530105
(1) (2) (3) (4) (5) (6) (7) (8) (9)
List extra codes in sequence, separated by commas. Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock. Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
1
Page 6
Data sheet 902435 Page 6/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
D
EL AL
Order details: Heat meter RTD temperature probe with connection cable,
MID approved A0445/2112/2007
(1) Basic type
902438/50
x 815 0 to 105 °C/PVC 105, PUR (only in 2-wire circuit) x 824 0 to 150 °C/Silicone
x 1003 1x Pt 100 in 2-wire circuit x 1004 1x Pt 500 in 2-wire circuit x 1005 1x Pt1000 in 2-wire circuit x 1011 1x Pt100 in 4-wire circuit x 1012 1x Pt500 in 4-wire circuit x 1013 1x Pt1000 in 4-wire circuit
x 1 Class B (standard)
x5Ø5mm x 5.2 Ø 5.2 mm x6Ø6mm
x 45 45 mm (only for Ø 5 mm and Ø 5.2 mm) x 50 50 mm (only for Ø 6 mm) x 60 60 mm (only for Ø 6 mm) x ... Specifications in plain text
x 04 Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit) x 11 Ferrules as per DIN 46228 Part 4 (standard)
x 1500 1500 mm x 2500 2500 mm (Standard) x ... Specifications in plain text (500 mm steps, max. connection cable length, see table)
x 000 None x 317 Shielded connection cable x 340 Version paired as per DIN EN 1434 x 761 Version paired as per DIN EN 1434 and CE and metrology sign (first calibration)
Push-in RTD temperature probe (PS) Thermowell made of stainless steel, for installation in a thermowell
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (45 to 85 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
Order code - - - - - - - / ,... Order example 902438/50 - 824 - 1003 - 1 - 5 - 45 - 11 - 2500 / 761
Note:
For the thermowell, refer to the data and price sheet 902440
1 2
2010-09-08/00530105
(1) (2) (3) (4) (5) (6) (7) (8) (9)
List extra codes in sequence, separated by commas. Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
1
Page 7
Data sheet 902435 Page 7/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
D
EL AL
Order details: Heat meter RTD temperature probe with connection cable,
MID approved DE-06-MI004-PTB011
(1) Basic type
902438/30
x 815 0 to 105 °C/PVC 105, PUR (only in 2-wire circuit) x 824 0 to 150 °C/Silicone x 830 0 to 180 °C/Silicone
x 1003 1x Pt100 in 2-wire circuit x 1004 1x Pt500 in 2-wire circuit x 1005 1x Pt1000 in 2-wire circuit x 1011 1x Pt100 in 4-wire circuit x 1012 1x Pt500 in 4-wire circuit x 1013 1x Pt1000 in 4-wire circuit
x 1 Class B (standard) x 2 Class A x 3 Class AA (1/3 DIN B)
x6Ø6mm
x 105 105 mm x 140 140 mm x 230 230 mm x ... Specifications in plain text
x 04 Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit) x 11 Ferrules as per DIN 46228 Part 4 (standard)
x 1500 1500 mm x 2500 2500 mm (Standard) x ... Specifications in plain text (500 mm steps, max. connection cable length, see table)
x 000 None x 317 Shielded connection cable x 340 Version paired as per DIN EN 1434 x 761 Version paired with CE and metrology sign (first calibration)
Push-in RTD temperature probe for installation in a thermowell (PL), Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (105 to 450 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
Order code - - - - - - - / ,... Order example 902438/30 - 830 - 1003 - 1 - 6 - 140 - 11 - 2500 / 761
Note:
For the thermowell, refer to the data and price sheet 902440
1 2
2010-09-08/00530105
(1) (2) (3) (4) (5) (6) (7) (8) (9)
List extra codes in sequence, separated by commas. Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
1
Page 8
Data sheet 902435 Page 8/8
JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-5866
1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us
D
EL AL
Order details: Cold / combined cold/heat meter RTD temperature probes with connection cable,
MID approved DE-06-MI004-PTB011, PTB approved 22.77/09.01
(1) Basic type
902465/30
x 824 0 to 150 °C/Silicone
x 1003 1x Pt100 in 2-wire circuit x 1004 1x Pt500 in 2-wire circuit x 1005 1x Pt1000 in 2-wire circuit x 1011 1x Pt100 in 4-wire circuit x 1012 1x Pt500 in 4-wire circuit x 1013 1x Pt1000 in 4-wire circuit
x 1 Class B (standard) x 2 Class A x 3 Class AA (1/3 DIN B)
x6Ø6mm
x 105 105 mm x 140 140 mm x 230 230 mm x ... Specifications in plain text
x 04 Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit) x 11 Ferrules as per DIN 46228 Part 4 (standard)
x 1500 1500 mm x 2500 2500 mm (Standard) x ... Specifications in plain text (500 mm steps, max. connection cable length, see table)
x 000 None x 317 Shielded connection cable x 340 Version paired as per DIN EN 1434 x 341 Version paired as per DIN EN 1434 and calibrated (cold, only for Germany) x 761 Version paired with CE and metrology sign (first calibration, heat)
Push-in RTD temperature probe for installation in a thermowell (PL), Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (105 to 450 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
2, 3
Order code - - - - - - - / ,... Order example 902465/30 - 824 - 1003 - 1 - 6 - 140 - 11 - 2500 / 341.761
Note:
For the thermowell, refer to the data and price sheet 902440
1 2 3
2010-09-08/00530105
(1) (2) (3) (4) (5) (6) (7) (8) (9)
List extra codes in sequence, separated by commas. Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock. Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
1