Push-in RTD temperature probe
for heat meter with connection cable
for immersion sleeves (type PS/PL)
For temperatures from 0 to 180 °C
Approval for heat meter MID and domestic approval
as exchangeable temperature probes
Meets the requirements as per DIN EN 1434, AGFW FW202 and FW211
Approval for cold meter and cold / heat meter combinations
Paired and calibrated as per the German calibration regulations
Production certified as per module D of the MID (CE and metrology sign)
Adapted accessoried for installation (data and price sheet 902440)
Heat meter RTD temperature probes are used for temperature measurement in closed-loop
pipe systems. Thanks to the installation in thermowells with tolerance on fit for optimum thermal
coupling, the system need no longer be discharged at the time of the regular exchange once
the certification period has elapsed.
The temperature probes are approved in accordance with the EU directive 2004/22/EC (MID)
as well as according to the German calibration regulations (domestic approval). The temperature probes are available paired and calibrated. The state-approved test body for heat KF2 is
responsible for this purpose. Moreover, the production is certified according to module D of
MID, and the temperature probes are also available with the CE and metrology sign.
Data sheet 902435Page 1/8
Note:
In Germany, temperature probes, type PS, with MID approval may no longer be installed in new
installations smaller than DN 25 pipe systems (4th. amendment of the Calibration Regulations).
Technical Data
Process connectionPush-in RTD temperature probe for thermowells (immersion sleeves)
ConnectionWire end ferrules
Connection cablePVC, PUR, TPE, Silicone; unshielded or shielded
ThermowellType PS: stainless steel Ø 5.0 mm, Ø 5.2 mm or Ø 6.0 mm
Measuring insertPlatinum temperature probe as per DIN EN 60751
TemperatureType PS: 0 to 150 °C
Temperature differenceType PS: 3 to 150 K
Minimum immersion depthType PS: > 15 mm
Fitting lengthType PS: 45 to 85 mm
Response behaviorType PS: t
Ambient conditionsClimatic 0 to 70 °C
AccessoriesFor the thermowell, refer to the data and price sheet 902440
2010-09-08/00530105
For the max. connection cable lengths, refer to the table on the following page
Type PL: stainless steel Ø 6.0 mm
Thermowell with tolerance to fit for thermowells
Rated value: Pt100, Pt500, Pt1000; class B
Connection: 2-wire/4-wire circuit
Type PL: 0 to 180 °C
Type PL: 3 to 180 K
Type PL: 30 mm
Type PL: 85 to 450 mm
= 15 s (installed in thermowell)
Type PL: t
Protection class IP65
Electromagnetic E1
Mechanical M3
Cable cross-sectionMax. connection cable length AL
for Pt100
0.22 mm
0.34 mm
0.50 mm
2
2
2
2500 mm12500 mm25000 mm
3500 mm17500 mm35000 mm
5000 mm25000 mm50000 mm
Max. connection cable length AL
for Pt500
Max. connection cable length AL
for Pt1000
Note:
Also take into account a possible connection cable length limitation due to the design approval of the arithmetic unit/counter.
For 4-wire circuit, the max. connection cable lengths are limited due to the requirements of the arithmetic unit/counter.
Push-in RTD temperature probe (PS) T
Thermowell made of stainless steel,
for installation in a thermowell
902435/05
(90.276-F40)
902435/50
Push-in RTD temperature probe (PS) T
Thermowell made of stainless steel,
for installation in a thermowell
(2) Operating temperature in °C
x x8150 to 105 °C/PVC 105, PUR (only in 2-wire circuit)
x8240 to 150 °C/Silicone
(3) Measuring insert
x x10031x Pt100 in 2-wire circuit
x x10041x Pt500 in 2-wire circuit
x x10051x Pt1000 in 2-wire circuit
x10111x Pt100 in 4-wire circuit
x10121x Pt500 in 4-wire circuit
x10131x Pt1000 in 4-wire circuit
(4) Tolerance class as per DIN EN 60751
xx1Class B (standard)
x2Class A
x3Class AA (1/3 DIN B)
(5) Thermowell diameter D in mm
xx5Ø5mm
x x5.2Ø 5.2 mm
xx6Ø6mm
(6) Fitting length EL in mm (45 to 85 mm)
x x4545 mm (only for Ø 5 mm and Ø 5.2 mm)
x x5050 mm (only for Ø 6 mm)
x x6060 mm (only for Ø 6 mm)
x x...Specifications in plain text
(7) Cable termination
x x04Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit)
x x11Ferrules as per DIN 46228 Part 4 (standard)
(8) Connection cable length AL in mm (> 500 mm)
x x15001500 mm
x x25002500 mm (Standard)
x x...Specifications in plain text (500 mm steps)
(9) Extra codes
x x000None
x x317Shielded connection cable
x x340Version paired as per DIN EN 1434
x x341Version paired as per DIN EN 1434 and calibrated
2
= 105 °C,
max.
= 150 °C,
max.
3
Order code-------/,...
Order example902435/10-815-1003-1-5-45-11-2500/341
Note:
For the thermowell, refer to the data and price sheet 902440
1
2
3
2010-09-08/00530105
(1)(2)(3)(4)(5)(6)(7)(8)(9)
List extra codes in sequence, separated by commas.
Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
Order details:Heat meter RTD temperature probe with connection cable,
PTB approved 22.30/91.05, 22.70/00.01
(1) Basic type
902435/30
x8150 to 105 °C/PVC 105 (only in 2-wire circuit)
x8240 to 150 °C/Silicone
x8300 to 180 °C/Silicone
x10031x Pt100 in 2-wire circuit
x10041x Pt500 in 2-wire circuit
x10051x Pt1000 in 2-wire circuit
x10111x Pt100 in 4-wire circuit
x10121x Pt500 in 4-wire circuit
x10131x Pt1000 in 4-wire circuit
x1Class B (standard)
x2Class A
x3Class AA (1/3 DIN B)
x6Ø6mm
x105105 mm
x140140 mm
x230230 mm
x...Specifications in plain text
x04Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit)
x11Ferrules as per DIN 46228 Part 4 (standard)
x15001500 mm
x25002500 mm (Standard)
x...Specifications in plain text (500 mm steps, max. connection cable length, see table)
x000None
x317Shielded connection cable
x340Version paired as per DIN EN 1434
x341Version paired as per DIN EN 1434 and calibrated
Push-in RTD temperature probe
for installation in a thermowell (PL),
Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (85 to 400 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2, 3
Order code-------/,...
Order example902435/30-830-1003-1-6-140-11-2500/341
Note:
For the thermowell, refer to the data and price sheet 902440
1
2
3
2010-09-08/00530105
(1)(2)(3)(4)(5)(6)(7)(8)(9)
List extra codes in sequence, separated by commas.
Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
Order details:Heat meter RTD temperature probe with connection cable,
MID approved A0445/2112/2007
(1) Basic type
902438/50
x8150 to 105 °C/PVC 105, PUR (only in 2-wire circuit)
x8240 to 150 °C/Silicone
x10031x Pt 100 in 2-wire circuit
x10041x Pt 500 in 2-wire circuit
x10051x Pt1000 in 2-wire circuit
x10111x Pt100 in 4-wire circuit
x10121x Pt500 in 4-wire circuit
x10131x Pt1000 in 4-wire circuit
x1Class B (standard)
x5Ø5mm
x5.2Ø 5.2 mm
x6Ø6mm
x4545 mm (only for Ø 5 mm and Ø 5.2 mm)
x5050 mm (only for Ø 6 mm)
x6060 mm (only for Ø 6 mm)
x...Specifications in plain text
x04Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit)
x11Ferrules as per DIN 46228 Part 4 (standard)
x15001500 mm
x25002500 mm (Standard)
x...Specifications in plain text (500 mm steps, max. connection cable length, see table)
x000None
x317Shielded connection cable
x340Version paired as per DIN EN 1434
x761Version paired as per DIN EN 1434 and CE and metrology sign (first calibration)
Push-in RTD temperature probe (PS)
Thermowell made of stainless steel,
for installation in a thermowell
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (45 to 85 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
Order code-------/,...
Order example902438/50-824-1003-1-5-45-11-2500/761
Note:
For the thermowell, refer to the data and price sheet 902440
1
2
2010-09-08/00530105
(1)(2)(3)(4)(5)(6)(7)(8)(9)
List extra codes in sequence, separated by commas.
Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
Order details:Heat meter RTD temperature probe with connection cable,
MID approved DE-06-MI004-PTB011
(1) Basic type
902438/30
x8150 to 105 °C/PVC 105, PUR (only in 2-wire circuit)
x8240 to 150 °C/Silicone
x8300 to 180 °C/Silicone
x10031x Pt100 in 2-wire circuit
x10041x Pt500 in 2-wire circuit
x10051x Pt1000 in 2-wire circuit
x10111x Pt100 in 4-wire circuit
x10121x Pt500 in 4-wire circuit
x10131x Pt1000 in 4-wire circuit
x1Class B (standard)
x2Class A
x3Class AA (1/3 DIN B)
x6Ø6mm
x105105 mm
x140140 mm
x230230 mm
x...Specifications in plain text
x04Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit)
x11Ferrules as per DIN 46228 Part 4 (standard)
x15001500 mm
x25002500 mm (Standard)
x...Specifications in plain text (500 mm steps, max. connection cable length, see table)
x000None
x317Shielded connection cable
x340Version paired as per DIN EN 1434
x761Version paired with CE and metrology sign (first calibration)
Push-in RTD temperature probe
for installation in a thermowell (PL),
Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (105 to 450 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
Order code-------/,...
Order example902438/30-830-1003-1-6-140-11-2500/761
Note:
For the thermowell, refer to the data and price sheet 902440
1
2
2010-09-08/00530105
(1)(2)(3)(4)(5)(6)(7)(8)(9)
List extra codes in sequence, separated by commas.
Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
x10031x Pt100 in 2-wire circuit
x10041x Pt500 in 2-wire circuit
x10051x Pt1000 in 2-wire circuit
x10111x Pt100 in 4-wire circuit
x10121x Pt500 in 4-wire circuit
x10131x Pt1000 in 4-wire circuit
x1Class B (standard)
x2Class A
x3Class AA (1/3 DIN B)
x6Ø6mm
x105105 mm
x140140 mm
x230230 mm
x...Specifications in plain text
x04Tin-plated wires (only for permanently connected temperature probes on the arithmetic unit)
x11Ferrules as per DIN 46228 Part 4 (standard)
x15001500 mm
x25002500 mm (Standard)
x...Specifications in plain text (500 mm steps, max. connection cable length, see table)
x000None
x317Shielded connection cable
x340Version paired as per DIN EN 1434
x341Version paired as per DIN EN 1434 and calibrated (cold, only for Germany)
x761Version paired with CE and metrology sign (first calibration, heat)
Push-in RTD temperature probe
for installation in a thermowell (PL),
Thermowell made stainless steel
(2) Operating temperature in °C
(3) Measuring insert
(4) Tolerance class as per DIN EN 60751
(5) Thermowell diameter D in mm
(6) Fitting length EL in mm (105 to 450 mm)
(7) Connection cable termination
(8) Connection cable length AL in mm (> 500 mm)
(9) Extra codes
2
2
2, 3
Order code-------/,...
Order example902465/30-824-1003-1-6-140-11-2500/ 341.761
Note:
For the thermowell, refer to the data and price sheet 902440
1
2
3
2010-09-08/00530105
(1)(2)(3)(4)(5)(6)(7)(8)(9)
List extra codes in sequence, separated by commas.
Price for pairing depends on the quantity; minimum quantity for paired temperature probes: 30 pairs for versions not in stock.
Calibration fees as per Federal Law Gazette No. 28 dd. 1.8.2001, quantity-dependent, not subject to discounts
1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.