Due to their special construction these robust, steam-tight insertion RTD temperature probes are
especially suited to cooking, boiling, and baking processes in all areas of food processing and
food preservation. Further application areas are autoclaves and sterilizers.
The stainless steel probe tube is available with either a concentric or an oblique probe tip (approx. 25° or 45°).
All versions have a highly vibration-resistant design. The handles are oil-resistant and acid-proof.
A Pt100 temperature sensor according to DIN EN 60751, class B, in a 2-wire circuit or 3-wire cir-
cuit is used as standard as a measuring insert.
Data sheet 902350Page 1/6
Technical data
ConnectionCable ends stripped bare; alternatively available with ferrules,
plug-in sleeves, or multi-pole plug connectors
Connecting cableSilicone, ambient temperature -50 to +180 °C
PTFE, ambient temperature -50 to +260 °C
Shielded connecting cable optionally available
HandlePPS plastic handle, ambient temperature max. +200 °C
Silicone handle, ambient temperature max. +200 °C
PTFE handle, ambient temperature max. +260 °C
FPM handle, ambient temperature max. +200 °C
PEEK handle, ambient temperature max. +260 °C
Protection tubeStainless steel 1.4571, Ø 4 mm, Ø 4.5 mm
Protection tube tipConcentric
Oblique
Measuring insertPt100 temperature sensor, DIN EN 60751, class B, 2-wire circuit
Insertion RTD temperature probe
with silicone handle Ø 10 mm
and silicone cable
Data sheet 902350Page 3/6
902350/23
902350/33
902350/63
with silicone handle Ø 10 mm
and PTFE cable
Insertion RTD temperature probe
with PTFE handle, Ø D1 = 12 mm
and PTFE cable
Insertion RTD temperature probe
with PTFE handle, Ø D1 = 15 mm
and PTFE cable
(2) Operating temperature in °C
x x380-50 to +200 °C
x x386-50 to +260 °C
(3) Measuring insert
xxxx10011× Pt100 in 3-wire circuit
xxxx10031× Pt100 in 2-wire circuit
xxxx10111×Pt100 in 4-wire circuit
xxxx20012× Pt100 in 3-wire circuit (not for silicone cables and protection tube diameter D = 4 mm)
xxxx20032× Pt100 in 2-wire circuit
(4) Tolerance class according to DIN EN 60751
xxxx1Class B (standard)
xxxx2Class A
(5) Protection tube diameter D in mm
xxxx4Ø4mm
xxxx4.5Ø4.5mm
Insertion RTD temperature probe
xxxx100100mm
(6) Insertion length EL in mm
xxxx150150mm
xxxx200200mm
(7) Insertion tip
xxxx2Concentric
xxxx3Oblique
(8) Connecting cable end
xxxx11Ferrules
xxxx80Multi-pole plug connector (specify type in plain text)
(9) Connection cable length AL in mm (500 to 500000 mm)
xxxx40004000 mm (standard)
xxxx. . .Specification in plain text (500mm increments)
(10) Extra code
xxxx000Without
xxxx317Shielded connecting cable
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
Order code-------- /
Order example902350/22-380-1003-1-4-100-3-11-4000/000
Insertion RTD temperature probe
with PPS plastic handle Ø 20 mm
and PTFE cable
Data sheet 902350Page 5/6
902350/83
902350/84
with PEEK handle
and PTFE cable
Insertion RTD temperature probe
with PEEK handle
and PTFE cable
(2) Operating temperature in °C
x380-50 to +200 °C
x x386-50 to +260 °C
(3) Measuring insert
x x x10011× Pt100 in 3-wire circuit
x x x10031× Pt100 in 2-wire circuit
x x x10111× Pt100 in 4-wire circuit
x x20012× Pt100 in 3-wire circuit (not for silicone cables and protection tube diameter D = 4 mm)
x x x20032× Pt100 in 2-wire circuit
(4) Tolerance class according to DIN EN 60751
x x x1Class B (standard)
xxx2Class A
(5) Protection tube diameter D in mm
xxx4Ø4mm
x4.5Ø 4.5 mm
(6) Insertion length EL in mm
x x x100100 mm (standard)
x x x150150 mm
Insertion RTD temperature probe
x x x2Concentric
(7) Insertion tip
x x x3Oblique
(8) Connecting cable end
x x x11Ferrules
x x x80Multi-pole plug connector (specify type in plain text)
(9) Connection cable length AL in mm (500 to 500000 mm)
x x x40004000 mm (standard)
x x x. . .Specification in plain text (500 mm increments)
(10) Extra code
x x x000Without
x x x317Shielded connecting cable
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
Order code----- ---/
Order example902350/83-386-1001-1-4.5-100-2-03-4000/000