Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount
LB Extended Models 900VA, 1700VA & 2500VA
On-line, Single Phase, Double Conversion UPS
The UniStar® V features a eld-proven Digital Signal Processor (DSP) achieving high reliability, while providing
protection from electrical power disturbances to the connected load. The convertible tower/rack design oers
maximum exibility, enabling UPS integration into a wide variety of environments.
Industry-leading functionality is standard and includes hot swappable battery, powerful internal charger,
emergency shut-down and programmable receptacles. The UniStar® V is an ideal power protection solution for
servers, networks, telecommunications, industrial equipment, and manufacturing processes. LB Models are for
those critical applications that require extended battery backup times.
True Double-Conversion
On-Line UPS
n
A true double conversion UPS will provide
clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer center servers,
telecom applications, as well as for industrial applications.
Output Power Factor 0.9
n
UniStar Series V is a high-density UPS with an output power factor 0.9 to provide higher performance and eciency to critical
applications.
User-Friendly and Easy-Shift LCD Display
n
The front panel digital display can be easily shifted through LCD setting to suit the installation format,
Tower or Rack mount
Rack/Tower Design
n
The Series V is designed in a true universal-mount case. It can be easily installed as a free-standing tower or in a 19-inch rackmount
conguration.
Programmable Power Management Outlets
n
With programmable power management outlets, users can easily and independently control load segments. During power failure,
this feature enables users to extend battery time to mission-critical devices by shutting down the non-critical devices.
50/60 Hz Frequency Converter Mode
n
Lock output frequency at 50Hz or 60Hz to suit power sensitive equipment.
ECO and Advanced ECO Mode for Energy Saving
n
It allows the UPS to operate in high eciency up to 97% in energy-saving ECO mode. In this operation mode, load is supplied
by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected
systems. The Series V even oers advanced ECO mode to allow UPS to operate at higher eciency up to 98%.
Emergency Power O Function (EPO)
n
This feature can secure the personnel and equipment in case of res or other emergencies.
Hot-Swappable Battery Design
n
Ensures clean and uninterruptible power to protected equipment during battery replacement.
www.stacoenergy.com
Your Tailored Power Solutions Provider
TM
On-Line, Single Phase
UPS System
The UniStar® V represents the latest in single-phase
technology at an aordable price. Its true on-line
performance provides a constant clean, steady sine wave
safeguarding the most sensitive equipment.
A full Three Year parts with depot repair or
replacement warranty is standard.
Battery:
A full One Year Warranty on the Battery System
ensures that your batteries are protected from
system failure now and in the future. (Warranty
provided by battery manufacturer.)
Extended warranties, customized
service plans and preventative
maintenance are also available.
Please refer to our warranty statement
for complete details.
User-friendly Plug-and-Play design
allows hassle-free installation. All units up
to 3000VA are supplied with input cables
and output receptacles as standard.
Innovative battery management cir-
cuit analyzes battery discharging status to
adjust battery cut-o point and extend the
batteries’ life span.
Internal maintenance-free sealed VRLA
batteries minimizes the need for frequent
after-sales service. The hot swappable bat-
tery feature allows users to replace the bat-
teries without the hazard of electric shock,
while the UPS supplies power continuously
to critical load applications.
Built-in Charger provides ability
to re-charge internal battery to
approximately 90% in four hours.
Matching battery cabinets are available
to extend the UPS runtime easily to
several hours.
Optional extended runtime
capability by simply connecting
additional battery packs. Just plug in the
battery connectors between the
UPS and battery packs without the require-
ment for additional chargers.
Optional Maintenance Bypass
Model NumberRatingInput ConnectionOutput Receptacles
USC-MBPDU-11RT1000VA & 900VAAttached 6' Cord with
USC-MBPDU-21RT2000VA & 1700VAAttached 6' Cord with
USC-MBPDU-31RT3000VA & 2500VAAttached 6' Cord with
Dimensions: 3.50" H x 17.30"W x 3.00"D (2U) / [88.9 x 439.4 x 76.2]
5-15P
5-20P
L5-30P
UniStar V Series, Universal Rack/Tower Mount
120VAC, 1000VA, 2000VA & 3000VA & LB Models, 900VA, 1700VA & 2500VA
UPS On-line, Double-Conversion – LCD Panel, USB and RS-232 Standard
Model Number
SCV-10001
SCV-20001
SCV-30001
SCV-10001-LB
SCV-20001-LB
SCV-30001-LB
Standard Models: Maximum (1) External Battery Pack (SCV-BAT-1K, SCV-BAT-2K or SCV-BAT-3K)
LB Models: Maximum (5) External Battery Pack (SCV-BAT-1K, SCV-BAT-2K or SCV-BAT-3K)
Note: 1. LB Models do not have internal batteries.
2. Unit ships with bundled NetAgent 9 Shutdown Software.
3. All units ship with floor stand and rack mount hardware.
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
VA/
Watts
1000VA / 900W 2.75-15P(4) 5-15R
2000VA / 1800W 2.75-20P(8) 5-20R
3000VA / 2700W 2.7L5-30P
900VA / 810W05-15P(4) 5-15R
1700VA /1530W05-20P(8) 5-20R
2500VA / 2250W0L5-30P
Internal
Battery
(Minutes)
Input
Cord
Output
Connection
(4) 5-20R &
(1) L5-30R
(4) 5-20R &
(1) L5-30R
H" x W" x D" / [mm]
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
(8) 5-15R
(6) 5-15R & (2) 5-20R
(4) 5-15R & (1) 5-30R
*Dimensions
*Wt.
lbs. / (kg)
29 / (13)
47 / (21)
65 / (29)
20 / (9)
28 / (13)
33 / (15)
Extended run time battery packs
are available for all models.
Size, capacity, and estimated run times
UniStar® V Rack/Universal
www.stacoenergy.com
Specication for 120/120VAC
MODEL (SCV)1000110001-LB2000120001-LB3000130001-LB
Capacity VA / Watts
INPUT
Rated Volts100VAC-120VAC
Low Transfer
Capacity
Frequency Range50Hz/ 60Hz
Power Factor
OUTPUT
Output Voltage100*/110*/115*/120VAC
AC Voltage Regulation ± 1%
Frequency Range 47 ~ 53 Hz or 57 ~ 63 Hz (Synchronized Range)
Frequency Range 50Hz ± 0.5% or 60Hz ± 0.5% (Bat. Mode)
Current Crest Ratio (CF)5:1 (max.)
Harmonic Distortion
(THDU)
Transfer Time
Waveform (Battery Mode)Pure Sinewave
EFFICIENCY
AC Mode86% (typical), 88% (peak)88% (typical), 90% (peak)
* Derate capacity to 95% when the output voltage is adjusted to 115VAC. Derate capacity to 90% when the output voltage is adjusted to 110VAC.
Derate capacity to 80% when the output voltage is adjusted to 100VAC.
**Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Load level 0-25%, 26-50%, 51-75% and 76-100%, Low Battery and Battery Good, Programmable Management
Outlets working, UPS On-Line, UPS in Frequency Converter Mode, UPS On Bypass, Alarm Disabled Indicator
and Battery Charger Working.
Input Voltage and Frequency, Output Voltage and Frequency, Battery Backup Time (hours/minutes), Fault
Indicator, Battery Voltage, Overload, and/or UPS Output is short circuited.
Low battery, Overload, Battery Not Connected, Overcharge, Site Wiring Fault, EPO Enabled, Over Temperature, Charger Failure,
Battery Fault, Bypass Out of Range and Bypass Frequency Unstable
3.39" x 17.24" x 16.44" (2U)
[86.2 x 438.0 x 417.5]
17.24" x 3.39" x 16.44" (2U)
[438.0 x 86.2 x 417.5]
< 2% (Linear load)
3.39" x 17.24" x 20.38" (2U)
[86.2 x 438.0 x 517.5]
17.24" x 3.39" x 20.38" (2U)
[438.0 x 86.2 x 517.5]
3.39" x 17.24" x 27.74" (2U)
[86.2 x 438.0 x 704.6]
17.24" x 3.39" x 27.74" (2U)
[438.0 x 86.2 x 517.5]
Staco Energy Products Co.
The UniStar® V Series Battery Run Time Charts
Standard External Battery Run Time Chart - Minutes Used with UniStar V Series, 120 VAC, Universal Tower/Rack 1000VA, 2000VA & 3000VA
UPS
Rating
I000VAInternal01/0251052.7
2000VAInternal01/0251052.7
3000VA Internal01/0251052.7
Note: 1. ONLY (1) Standard Battery Pack can be used on the SCV-X0002 Models without effecting recharge time.
If (2) battery packs are used the recharge will take twice the time.
2. If longer run times are needed or future expansion is planned the LB Model is recommended.
3. Run times included total of internal and external battery strings.
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights
Part Number
SCV-BAT-1K
SCV-BAT-2K
SCV-BAT-3K
Quantity
Cabinets
11/2402518
11/2402518
11/2402518
Standard External Battery Run Time Chart - Minutes Used with UniStar V, 120VAC, LB Models, Universal Rack/Tower 900VA, 1700VA & 2500VA
UPS RatingPart Number
900VA Internal000000
1700VAInternal000000
2500VA Internal000000
Note: Weights include the total of all cabinets
*Always reference Spec Control Drawing (SCD) for the most current & accurate dimensions and weights