JuiceGoose RX15-DPC User Manual

RX SERIES
HYBRID AC POWER FILTERS
O W N E R’ S M A N U A L
RX15- DPCTM
RX10- SCS
7320 Ashcroft, Suite 104
Houston, Texas 77081
Phone: 713.772.1404
Fax: 713.772.7360
www.juicegoose.com
TM
RX Series Owners Manual ... page 1
02-07 R2
Tuesday, February 13, 2007 14:29
The Juice Goose RX Series products are AC power condi­tioners that protect against AC line surges and line noise. These devices use an advanced, patented hybrid AC filter technology which protects against high voltage electric power surges and disruptive, high frequency line noise on the hot, neutral and ground power leads.
GENERAL SAFE USE PROCEDURES
> Use indoors only. > Avoid dropping the unit. > Only plug the RX product into a three pronged grounded outlet. This unit is not to be used with any type of ground “lift” or pin eliminator. > Do not open the RX product. There are no user serviceable parts inside. Opening the unit will void your
warranty.
DISCLAIMER
Juice Goose shall under no circumstances be held respon­sible for any losses, damage, or injury resulting directly or indirectly from the use of a RX Series device in a manner contrary with accepted, safe operating methods or any instructions contained in this document. The user should determine prior to use whether this product is adequate, suitable or safe for the application intended. Since individual applications can be subject to extreme variation, Juice Goose makes no representation or guar­antee as to the suitability of a RX product for any gen­erally described application.
CONNECTION AND OPERATION
1. Turn off and un-plug electronic equipment.
2. Plug the equipment into the RX unit.
3. Plug the RX unit into a grounded wall outlet.
4. Observe the monitoring lights on the RX device. The GREEN light confirms properly connected equipment is
RX Series Owners Manual ... page 2
Tuesday, February 13, 2007 14:29
fully protected. The RED light indicates faulty site wiring which needs to be inspected. This fault relates to the wir­ing connected to the wall output. Fault conditions that would be indicated by the RED light include reverse hot and neutral leads, missing safety ground and voltage in excess of 165 volts for over 3 seconds.
Important: if the RED light comes on, for protection pur­poses, the RX unit will not provide power to connected equipment. Once the fault has been corrected the GREEN light will come on and power will be applied to connected equipment.
Do not attempt to repair faulty wiring. Contact a licensed electrician.
Some RX Series products are equipped with RJ style con­nectors that can provide protection for telephone/modem lines or ethernet data network lines.
5. Plug any source telephone/modem cables into the com­bination RJ11/RJ45 connector marked “LINE”. Plug the de­vice to be protected into the connector marked ”DEVICE”.
6. Use standard CAT5 cable when using the Network pro­tected RJ45 circuit.
RX Series Owners Manual ... page 3
Tuesday, February 13, 2007 14:29
RX SERIES
SPECIFICATIONS
DIMENSIONS (in) RX15-DPC 13.5 x 4.5 x 2
RX10-SCS 2.5 x 4 x 2 CURRENT RATING (AMPS) RX15-DPC 15
RX10-SCS 10
AC POWER RECEPTACLES NEMA 5/15
RX15-DPC 9
RX10-SCS 1
TRANSIENT ENERGY ABSORBTION (JOULES) 1020
MAXIMUM APPLIED SURGE CURRENT (AMPS) 3000
MAXIMUM APPLIED SURGE PULSE VOLTAGE (VOLTS) 6000
SURGE LET THROUGH RATE (VOLTS)
L-N 10 N-G 0.5
COMMON MODE (N - G) LINE NOISE REDUCTION (dB)
100kHz 30 300kHz 77 1 MHz 80 10MHz 80
30MHz 80
NORMAL MODE (L-N) LINE NOISE REDUCTION (dB)
100kHz 21 300kHz 56 1 MHz 60 10MHz 60 30MHz 60
RX Series Owners Manual ... page 4
Tuesday, February 13, 2007 14:29