FEATURES SUMMARY
RX100-RM features include:
* Less than 1 volt surge potential between neutral and ground
* Less than 10 volt surge potential between neutral and line
* Over voltage and wiring fault shut down
* An all steel Tour Class
* Eight 120 volt power outputs (6 switched 2 unswitched)
* Fifteen amp, 1800 watt current rating
SAFETY PRECAUTIONS The RX100-RM is designed to operate with 120VAC, 60 Hz. Opera­tion with 220 or 240 volts will damage the unit and possibly cause personal injury.
CAUTIONS
1. The RX100-RM must be grounded to operate. Defeating the unit’s grounding capability could create a hazard.
2. There are no user serviceable parts inside the RX100-RM. Do not attempt service yourself. Contact Juice Goose as directed in this manual if service is required.
3. Do not expose the RX100-RM to moisture. Avoid severe physical impacts to the unit.
DISCLAIMER Juice Goose shall under no circumstances be held responsible for any loss, damage or injury resulting from the use of the RX100-RM in a manner inconsistent with any of the procedures outlined in this document. The user is responsible for determining whether this product is appropriate for the intended application.
Juice Goose is not responsible for any indirect, secondary or ancil­lary loss or damage, including personal injury, loss of or damage to property or loss of income resulting from the operation or fail­ure of this unit.
chassis
(tm)
Page 3
RX100-RM SPECIFICATIONS
DIMENSIONS (INCHES) 1.72 x 19.00 x 7.00
WEIGHT (LBS) 12
POWER INPUT 120 VAC, 60Hz
POWER OUTLETS 8 NEMA 5-15R (2 unswitched)
CURRENT CAPACITY 15 AMPS
POWER CORD 12 FOOT, 14/3 SJT
TRANSIENT ENERGY ABSORBTION (JOULES) 1020
MAXIMUM APPLIED SURGE CURRENT (AMPS) 3000
MAXIMUM APPLIED SURGE PULSE VOLTAGE (VOLTS)
SURGE LET THROUGH RATE (VOLTS)
L-N 10
N-G 0.5
COMMON MODE (N-G) LINE NOISE REJECTION (dB)
100 kHz 30
300 kHz 77
1 MHz 80
10MHz 80
30MHz 80
NORMAL MODE (L-N) LINE NOISE REJECTION (dB)
100 kHz 21
300 kHz 56
1 MHz 60
10MHz 60
6000
30MHz 60
CHASSIS DESIGN TOUR CLASS – UNIBODY
CHASSIS FINISH POWDER COAT ENAMEL
Page 4
FRONT PANEL Power On/Off Switch – This lighted rocker switch is located on the left hand side of the chassis. The switch will light when the RX100-RM is on.
AC Outlets – One unswitched NEMA 5-15R rated for current loads up to 15 amps at 120 volts.
Indicator Lights Power – This blue light indicates the RX100-RM is connected to mains power and the ON switch is engaged. Protection OK – This blue light indicates the RX100-RM protection circuit is functioning and the main AC power source is correct. External Fault – In the event of continuous high voltage or incorrect wir­ing of the line, neutral or ground leads supplying the RX100-RM, the unit will disconnect equipment plugged into it. The blue Protection OK light will be OFF and the white External Fault indicator will light.
REAR PANEL AC Outlets – Seven NEMA 5-15R outlets (one unswitched) rated for current loads up to 15 amps at 120 volts.
BreakerA resettable, thermal circuit breaker protects the unit from current overloads. If the breaker trips check for a malfunction in equip­ment plugged into the RX100-RM. Also check to be certain the total cur­rent requirement of the equipment plugged into the RX100-RM does not exceed 15 amps.
The circuit breaker may be reset. Wait 30 seconds after the breaker trips, turn off the main unit power switch and push the center button on the breaker back into its original position. Then turn on the main power switch.
INTERNAL PROTECTION COMPONENTS The RX100-RM is one of the RX Series products which feature PoweRX AC power protection. PoweRX protection uses a new, patented Hybrid AC Filter technology to clean up both Normal Mode and Common Mode noise without contaminating the ground. Normal Mode noise occurs be­tween the line and neutral leads of an electric power circuit. Common Mode noise occurs between either the line or neutral and the safety ground lead.
UL 1449 limits the amount of current that can pass between line and safety ground to 0.5 milli amperes. This is called " leakage current". The Hybrid AC Filter process control board, by using a differential trans­former and capacitors, acts as a low pass, "line conditioning" filter
Page 5
which performs in the same way as a series mode inductor. These components, along with a capacitor between neutral and ground comprise the foundation of the Hybrid AC Filter design which condi­tions incoming AC power, removing normal and common mode noise without adversely affecting the ground line.
TROUBLESHOOTING The RX100-RM is ruggedly designed and constructed from high qual­ity components to give years of dependable power for your equip­ment. It requires neither maintenance nor adjustment. It is unlikely to malfunction. However, there is one potential event to note:
The RX100-RM will not come on or turns itself off. a. Check the status of the power supplied to the unit. If line voltage exceeds 165 volts for 3 seconds protection circuitry will dis­connect power to the AC power outputs. This will also occur if the line and neutral leads are reversed. Use a voltage meter and/or po­larity tester to examine the status of incoming power. b. Check that the circuit breaker is not tripped and that the current load on the unit does not exceed its rated 15 amp capacity. If the breaker is tripped, remove sufficient current load to reduce the total to no more than 15 amps, wait approximately 30 seconds after the tripping, turn off the main power switch and push in the circuit breaker button.
If an observed problem can not be remedied, particularly if the prob­lem seems severe or dangerous, discontinue use of the RX100-RM and contact Juice Goose directly.
REPAIR Should your Rackpower need service contact Juice Goose for assis­tance and authorization to return the unit. PLEASE NOTE: a return authorization number is required in order for the service personnel to correctly and promptly identify, repair and return your unit. You may obtain a Return Authorization Number by calling: 713-772-1404 or sending email to info@juicegoose.com.
Page 6
OTHER HIGH QUALITY PRODUCTS FROM
JG SERIES – Rack mountable power distribution in a 19” con-
figuration. Five models to choose from. Feature options include rack lighting and voltage meter. The JG11-20A has a 20 amp ca­pacity, 2 unswitched outlets and a 15 foot power cord. All units contain a basic level of power conditioning.
PD SERIES – Custom configured power strips with up to 12 cir-
cuits per unit. The PD1A, PD1B and PD3 offer various options re­garding size, number and arrangement of circuits, length and loca­tion of wire harness and mounting configuration. Select exact con­figuration with a features menu.
CQ SERIES – Power sequencing and remote control products.
No master controller is required. Very flexible, economical and easy to install. Models include rack mount, four circuit and 30 amp de­signs. Optional remote controls include key or rotary switch and secure 12 position keypad.
UPS MODELS – When protection against power outage is
needed, Juice Goose is a source for 16 models of UPS products, rack or tower mount, line interactive or on line. Call or email for any specification or application assistance.
Loading...