JG SERIES – Rack mountable power distribution in a 19” configuration.
Seven models to choose from. Feature options include incandescent or
LED rack lighting and voltage meter. The JG11-20A has a 20 amp capacity, 2 unswitched outlets and a 15 foot power cord. All units contain
a basic level of power conditioning.
PD SERIES
unit. The PD1A, PD1B and PD3 offer various options regarding size,
number and arrangement of circuits, length and location of wire harness
and mounting configuration. Se lect exact configuration with a features
menu.
CQ SERIES
master controller is required. Very flexible, economical and easy to install. Models include rack mount, in-wall, four circuit and 30 amp designs. Optional remote controls include key or rotary switch.
UPS MODELS
Juice Goose is a source for 8 models of UPS products, rack or tower
mount, line interactive or on line. Call or email for any specification or
application assistance.
– Custom configured power strips with up to 12 circuit s per
– Power sequencing and remote control products. No
– When protection against power outage is needed,
RP100-15A & RP100-20A
Power monitoring, surge protection
and distribution
OWNERS MANUAL
Houston, Texas
p: 713.772.1404
info@juicegoose.com
www.juicegoose.com
Jun 2018
REPAIR
Should your RACKPOWER need service contact Juice Goose for assistance and authorization to return the unit. Please Note: a return au-
thorization number is required in order for the service personnel to correctly and promptly identify, repair and return your unit. You may obtain
a Return Authorization Number by calling: 713-772-1404 or sending
email to info@juicegoose.com.
WARRANTY
Whitenton Industries, Inc, dba JUICE GOOSE, warrants as the only
warranty that products shall display freedom from defects in materials
and workmanship when operated under normal use and service subject
to the “Limitations and Conditions” listed below, for THREE YEARS
from the original purchase date of the unit. This date shall be the date
on which the unit was purchased from a commercial retail business. If
during this warrant y period a defect should occur , the product may be
repaired or replaced at the option of JUICE GOOSE. This warranty is
transferable to a repurchaser for the period stated above. The warranty
holder shall pay the cost of returning the unit to JUICE GOOSE or its
designated repair location. JUI CE GOOSE shall pay the cost of returning the unit to the warranty holder by normal ground parcel delivery.
Limitations and Conditions: The above warranty applies to all products
of JUICE GOOSE and all components thereof with the exception of
model JG Junior and any circuit board mounted electronic components
which shall be warranted for ONE YEAR from the purchase date of the
unit.
Even though JUICE GOOSE has tested each product, under no circumstances shall JUICE GOOSE, or an yone else involved in the creation,
production and distribution of these products be liable for any damages,
including any lost profits, lost savings or other direct, indirect, special,
incidental or consequential charges even if JUICE GOOSE or an authorized JUICE GOOSE dealer has been advised of the possibility of
such damage, or any claim or claims by other parties. In particular,
JUICE GOOSE shall have no liability for any programs or data stored in
equipment powered by JUICE GOOSE products nor liability for lost
revenues related directly or indirectly to the operation of JUICE GOOSE
products.
The warranty and remedies set forth above are exclusive and in
lieu of all others, oral or written, expressed or implied. No JUICE
GOOSE dealer, agent or employee is authorized to make modification, extension or addition to this warranty.
REAR PANEL
AC Outlets – The nine outlets (NEMA 5-15R) on the 15A model are
rated for current loads up to 15 amps at 120 volts. The 20A model has
8 NEMA 5-15R and 1 NEMA 5-20R which is rated for a current load of
20A at 120volts. The outlets are rotated and spaced to accommodate
plugging in AC power adapters (a.k.a. “wall warts”).
USB Power Port - The USB connector on the back of the chassis provides 5 volts of DC current for use powering a plug-in LED light or for
charging an electronic device such as an MP3 player or cell phone.
This port is specially designed to charge iPhones and most other smart
phone models. (A USB Port is also located on the front of the chassis.)
TROUBLESHOOTING
The RACKPOWER is ruggedly designed and constructed from high
quality components to give years of dependable power for your equipment. It requires neither maintenance nor adjustment. It is unlikely to
malfun ction.
The RACKPOWER will not come on or turns itself off.
a. Check the status of the power supplied to the unit. Be sure
AC utility power is available at the location where the unit is plugged in.
b. Check that the circuit breaker is not tripped. If the current
load on the unit exceeds 15 amps (or 20 amps on the 20A model) the
combination power switch and circuit breaker onto the front of the
RACKPOWER will prevent power from passing through the unit. If that
happens, remove sufficient current load to reduce the total to no more
than 15 amps (or 20 amps on the 20A model) , wait approximately 30
seconds after the tripping and place the switch in the up, “on” position.
If an observed problem can not be remedied, particularly if the problem
seems severe or dangerous, discontinue use of, unplug the RACKPOWER unit and contact Juice Goose directly.
The Surge Protection OK LED is not lit.
(See the “Front Panel” section of this manual.) This could indicate one
or more of the surge protection components in the RACKPOWER are
damaged. While it is possible some level of protection continues, that
protection would be below product specification. In that case, the RSP
surge protection module can be replaced. This is a safe and easy process which should be performed by a qualified technician according to
instructions provided by Juice Goose. Replacement RSP modules are
available from Juice Goose at a nominal price. Contact Juice Goose
( info@juicegoose.com or 713-772-1404) for more information.
FEATURES SUMMARY
Digital LED meter to monitor volts and amps
USB power ports on the front and back
Ten AC receptacles designed to accommodate wall warts
Tour Class (tm) chassis with reinforced mounting brackets
Replaceable surge protection circuit
SAFETY PRECAUTIONS
The RP100 (“RACKPOWER”) series are designed to operate with
120VAC, 60 Hz. Operation with 220 or 240 volts will cause damage and
possibly personal injury.
CAUTIONS
1. The RACKPOWER must be grounded to operate. Defeating
the unit’s grounding capability could create a hazard.
2. There are no user serviceable parts inside the RACKPOWER. Do not attempt service yourself. Contact Juice Goose
as directed in this manual if service is required.
3. Do not expose the RACKPOWER to moisture. Avoid severe
physical impacts to the unit.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any
loss, damage or injury resulting from the use of the RACKPOWER in a
manner inconsistent with any of the procedures outlined in this document. The user is responsible for determining whether this product is
appropriate for the intended application.
Juice Goose is not responsible for any indirect, secondary or ancillary
loss or damage, including personal injury, loss of or damage to property or loss of income resulting from the operation or failure of this unit.
SPECIFICATIONS
DIMENSIONS (H x W x D Inches)............................................1.72 x 19.00 x 7.00
CHASSIS DESIGN............................................................Tour Class
VOLTAGE INPUT...........................................................................120 VAC, 60Hz
USB PORTS................................................................................5 VDC @ 500mA
POWER OUTLETS
Fifteen Amp Units..........................................................10 NEMA 5-15R
Twenty Amp Units.................................8 NEMA 5-15R, 2 NEMA 5-20R
POWER CORD
Fifteen Amp Units.............................7 Foot, 14/3 SJT with NEMA 5-15P
Twenty Amp Units............................7 Foot, 12/3 SJT with NEMA 5-20P
POWER METER
Voltage.....................................................0 to 240 VAC to nearest tenth
Amperage...................................................0.40 to 25.0 to nearest tenth
TRANSIENT ENERGY ABSORBTION...................................................300 joules
PEAK SURGE CURRENT (Line, Neutral & Ground)..............30,000 amps / mode
Unibody
(TM)
FRONT PANEL
Combination On/Off Switch and Circuit Breaker – The rocker switch
located on the right side of the chassis is a dual function component. It
is normally used to manually turn the RACKPOWER on and off. In t he
event of a prolonged current load in excess of fifteen amps (twenty
amps on the 20A models) the circuit breaker will trip to shut off power.
(See the Troubleshooting section of this manual.)
.
AC Power Meter - The dual function, digital meter uses red LEDs to
report power line voltage and the current load being drawn from the
RACKPOWER. A push button to the left of the meter toggles the meter
display between voltage and amperage. Voltage metering is displayed
to the nearest one tenth volt. Amperage is displayed to the nearest one
tenth amp through a range from 0.4 amps to 25.0 amps. The display
will flash as a warning when voltage is greater than 139VAC or amperage is greater than 13.9A (18.9A for the 20A model) are reached.
USB Power Port - The USB connector on the front of the chassis provides 5 volts of DC current for use powering a plug-in LED light or for
charging an electronic device such as an MP3 player or cell phone.
This port is specially designed to charge iPhones and most other smart
phone models. (A USB Port is also located on the back of the chassis.)
AC Receptacle - The A C receptacle on the left of the chassis is powered whenever the RACKPOWER is plugged into a live AC power
source. It is rated at 15 amps or 20 amps and provides all the AC power
protection of the RACKPOWER.
Surge Protection OK - The RACKPOWER 100 features a replaceable
surge protection (RSP) module that includes three surge protection
components (MOVs). The white LED on the front panel is connected to
the primary MOV and is lit to indicate the surge protection components
are undamaged and functioning. In the event of MOV damage due to
AC power line fault or due to excessive wear over an extended period,
that LED will no longer be lit, indicating surge protection may no longer
be working. Note: It is possible, but unlikely, the two secondary MOVs
are no longer protecting but the primary one is. In that case, the RSP
surge protector is still working, but with a lower capacity to sustain
power line surges. It is also possible that the primary MOV is no longer
functioning, causing the protection LED to go out while the two secondary MOVs are still working. In either case, it is advisable to replace the
RSP. (See the Trouble Shooting section of this manual.)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.