SAFETY PRECAUTIONS
The JG Junior (JGJr) is designed to operate with 120VAC, 60 Hz. Operation with 220 or 240
volts will damage the unit and possibly cause personal injury.
CAUTIONS
1. The JGJr must be grounded. Defeating the unit’s grounding capability could
create a hazard.
2. There are no user serviceable parts inside. Do not attempt service yourself.
Contact Juice Goose as directed in this manual if service is required.
3. Do not expose the JGJr to moisture. Avoid severe physical impacts to the unit.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any loss, damage or injury resulting from the use of the JGJr in a manner inconsistent with any of the procedures
outlined in this document. The user is responsible for determining whether this product is
appropriate for the intended application.
Juice Goose is not responsible for any indirect, secondary or ancillary loss or damage, including personal injury, loss of or damage to property or loss of income resulting from the
operation or failure of this unit.
FRONT PANEL
Combined Power On/Off Switch & Circuit Breaker – This rocker switch acts as a master
power control switch and a current overload protector, rated for a maximum of 15 amps.
The circuit breaker may be reset. Wait 30 seconds after the breaker trips, then turn on the
main power switch.
REAR PANEL
AC Outlets – These 6 outlets (NEMA 5-15R) are rated for current loads up to 15 amps at
120 volts.
Power Cord – The power cord has a third pin safety ground connector. Do not defeat this
feature. Doing so could subject user to a hazardous condition.
INTERNAL PROTECTION COMPONENTS
The JGJr has a Basic Level of AC power protection consisting of fast acting metal oxide
varistors between hot, neutral and ground. The JGJr also features a line capacitor between
hot and neutral to reduce high frequency line noise and AC line surges.