SAFETY PRECAUTIONS
The JG 8 Series products (JG8) are designed to operate with 120VAC, 60 Hz. Operation with
220 or 240 volts will cause damage and possibly cause personal injury.
CAUTIONS
1. The JG8 must be grounded. Defeating the unit’s grounding capability could
create a hazard.
2. There are no user serviceable parts inside. Do not attempt service yourself.
Contact Juice Goose as directed in this manual if service is required.
3. Do not expose the JG8 to moisture. Avoid severe physical impacts to the unit.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any loss, damage or injury resulting from the use of the JG8 in a manner inconsistent with any of the procedures
outlined in this document. The user is responsible for determining whether this product is
appropriate for the intended application.
Juice Goose is not responsible for any indirect, secondary or ancillary loss or damage, including personal injury, loss of or damage to property or loss of income resulting from the
operation or failure of this unit.
FRONT PANEL
Lighted Power On/Off Switch – This switch controls power to all 8 outlets on the back of
the chassis.
Light Tubes (JG8.0L and JG8.0LM) - The JG 8.0L and 8.0LM feature two pull out dimmable
lights that can be rotated to control the intensity and direction of the two light beams. After use, the lights slide inside the chassis to store conveniently away. These devices use 7
watt "night light" style bulbs whic h install from the front of each light tube assembly. To
replace bulbs, unscrew front tube cap and rotate bulb counter clockwise .
Voltage Meter (JG8.0LM) - The JG8.0-LM includes a 20 segment Voltage Meter that indicates levels of incoming AC voltage. This color coded meter displays safe (green), marginal (yellow) and dangerous (red) levels of incoming voltage. This meter can help diagnose problems that result from common AC power sags and swells.
REAR PANEL
AC Outlets – These 8 outlets (NEMA 5-15R) are rated for current loads up to 15 amps at
120 volts.
Power Cord – The power cord has a third pin safety ground connector. Do not defeat this
feature. Doing so could subject user to a hazardous condition.
JG 8 Series Owners Manua...
page 2
Monday, June 21, 2004 11:22

INTERNAL PROTECTION COMPONENTS
The JG8 Series products have a Basic Level of AC power protection consisting of fast acting
metal oxide varistors between hot, neutral and ground. The JGJr also features a line capacitor
between hot and neutral to reduce high frequency line noise and AC line surges.
TROUBLE SHOOTING
The JG8 is well designed and constructed. Every JG8 is submitted to a full functional test before being shipped by Juice Goose. It requires neither maintenance nor adjustment. It is unlikely to malfunction. However, there are potential events to note:
The JG8 will not come on or turns itself off.
a. Check the status of the power supplied to the unit. Use a voltage meter and/or
polarity tester to examine the status of incoming power.
b. Check that the circuit breaker is not tripped and that the current load on the unit
does not exceed its rated 15 amp capacity. If the breaker is tripped, remove sufficient current
load to reduce the total to no more than 15 amps, wait approximately 30 seconds after the tripping. Turn the power switch/circuit breaker back on.
One or both lights will not come on (JG8.0L and JG8.0LM). – Unplug power to the JG8. Unscrew the cap on the end of the tube(s). Remove the bulb(s) in question. Take care. If the
bulb is broken use a cloth or needle nose pliers to remove the component. The replacement
bulb is a 7 watt, candelabra base (e.g. night light bulb).
If an observed problem can not be remedied, particularly if the problem seems severe or dangerous, discontinue use of the JG8 and contact Juice Goose directly.
REPAIR
Should your product need service contact Juice Goose for assistance and authorization to
return the unit. PLEASE NOTE: a return authorization number is required in order for the
service personnel to correctly and promptly identify, repair and return your unit.
You may obtain a Return Authorization Number by calling: 713-772-1404 or sending email to
info@juicegoose.com.
JG 8 Series Owners Manua...
page 3
Monday, June 21, 2004 11:22

OTHER HIGH QUALITY PRODUCTS FROM
JG SERIES – Rack mountable power distribution in a 19” configuration. Five models to
choose from. Feature options include rack lighting and voltage meter. The JG11-20A has a
20 amp capacity, 2 unswitched outlets and a 15 foot power cord. All units contain a basic
level of power conditioning.
RP SERIES – Professional grade rack mountable power distribution. The 19” rack mount-
able Tour Class
11 outlets across the back. The RP200 includes two slide out rack lights and a voltage meter.
The RP200-L includes a connector for a work light on the back of the chassis. All RP Series
models include enhanced components for EMI filtration in addition to voltage spike protection across hot, neutral and ground leads.
PD SERIES – Custom configured power strips with up to 12 circuits per unit. The PD1A,
PD1B and PD3 offer various options regarding size, number and arrangement of circuits,
length and location of wire harness and mounting configuration. Select exact configuration
with a features menu.
CQ SERIES – Power sequencing and remote control products. No master controller is
required. Very flexible, economical and easy to install. Models include rack mount, four circuit and 30 amp designs. Optional remote controls include key or rotary switch and secure
12 position keypad.
RX SERIES – High voltage surge protection and high frequency line filtration, perform-
ance near that of an isolation transformer, but at a fraction of the cost and size. Great normal
mode and common mode line noise elimination. Individual products include the RX15-PWG,
RX15-DPC, RX10-SCS and RP100-RX.
FE SERIES – The highest quality power conditioning available, isolation + regulation
transformers provide safe and stable power with a long service life. Models are available for
plug-in and hard wired applications in a wide range of sizes and voltages. FE Series transformers maintain a constant output voltage when incoming voltage swings +10% or – 20%.
UPS MODELS – When protection against power outage is needed, Juice Goose is a
valuable resource. Juice Goose has manufactured and supplied power conditioning and distribution products since 1983 and provides consulting and distribution service for our customers needing a UPS from APC, Liebert or PowerWare. Call Juice Goose to discuss the
best technology, size and configuration for a particular application.
chassis is a uni-body construction of extra sturdiness. The RP100 has
(TM)
JG 8 Series Owners Manua...
page 4
Monday, June 21, 2004 11:22