JUICE GOOSE iP1515, iP1520 Owner's Manual

(Quickstart Section is on Page 2.)
OWNER’S
MANUAL
iP 15 Series
WEB CONTROLLED
AC POWER DISTRIBUTION
8/15
INTRODUCTION
iP 15 Series
WEB BASED REMOTE POWER CONTROL
The Juice Goose iP1515 and iP1520 are microcontroller b ased power distribu­tion devices that can be accessed via Internet or intranet communications usin g Ethernet or RS232 connection. With this remote access, individual AC recepta­cles can be turned on and off and AC power receptacles can be monitored for electrical current flow.
The iP1515 has a 15 amp capacity. The iP1520 has a 20 amp capacit y. Both provide AC line conditioning and surge protection.
SAFETY PRECAUTIONS
The iP15 Series products are designed to operate at 120 volts, 60 hertz. Opera­tion with any voltage or frequency other than that can damage the equipment and create an unsafe situation.
CAUTION #1: These devices must be grounded. If a power extension cord is required, use a properly insulated and grounded cord. Failure to ground the device could expose the user to dangerous electric shock.
CAUTION #2: These devices should be installed only by qualified electrical technicians using appropriate mounting hardware and correct installati on tech­niques. Before installing make sure main power is off.
CAUTION #3: Do not expose these products to moisture or salty air. Doing so could cause significant damage and create an unsafe condition.
DISCLAIMER
Juice Goose shall under no circumstances be held respons ible for any losses, damage, or injury resulting directly or indirectly from the use of the iP15 devic e in a manner contrary to accepted safe operating methods or any instru ctions contained in this document. The user should determine prior to use whether this product is adequate, suitable and safe for the application i ntended. Since indi­vidual applications can be subject to extreme variation Juice Goose mak es no representation or guarantee as to the suitability of the iP1515 or the iP1520 for any generally described application.
Page 1
QUICKSTART GUIDE
1. Unbox the unit. The box should contain: iP15 Series de vice, Quick Start Guide, warranty card and Juice Goose promotional material. You will need a CAT5 network cable if attaching to a router, a CAT 5/6 crossover cable if connecting directly to a PC and a custom RS232 cable if you wish do con­nect via RS232 (see page 13 for a diagram on how to build the RS232 ca­ble).
2. With your PC on and booted up, connect the iP15 to your router or PC using a suitable cable. If the iP15 is connected to a network router use a standard CAT 5 cable, if connected directly to a PC use a CAT 5/6 cross­over cable.
3. Plug the iP15 power cord into a live AC receptacle, such as a wall outlet, with a twenty amp capacity (i.e. NEMA 5-20R).
4. The iP15 will take about 30 seconds to boot up and configure itself at which point the Network light on the front of the unit will illuminate, indicat­ing network connectivity. If the Network light blinks or does not light at all check the cable connections.
5. Open up your web browser and type in the follo wing default IP address to access the iP15: http://juicegoose.
6. At this point you will be prompted to log into the iP15. Initial login will be:
Username: admin Password: juicegoose
7. You will be presented with the control section where you can control the iP15 PODS by clicking on the buttons or using the Sequence fiel d b y enter ­ing the value in seconds and clicking the Sequence UP button.
8. To setup a specific IP address, change passwords for the admin/user account or configure other advanced features of the iP device click on the iP Series Management link at the top right of the displayed page. You will need to be logged in as admin to access this section. This section is de­scribed in more detail beginning on page 6.
See your system administrator, if you have one, for help with configuration.
Page 2
DETAIL SPECIFICATIONS
CHASSIS…………………………………………………………..………………...16 Gauge Steel
DIMENSIONS (inches)……………………………………..….....………...1.72H x 19.0W x 7.0D
WEIGHT (lbs)……………………………………………………………………………………..10.0
CIRCUIT BREAKER.........................…..…15A (iP1515) or 20A (iP1520) back panel, thermal
POWER INPUT CORD..…….....7 Foot, SJTW with NEMA 5/15P (iP1515) or 5/20P (iP1520)
(Note: iP1520 requires a NEMA 5/20R receptacle)
VOLTAGE INPUT.……….....…………………………………………………...120 VAC at 60 Hz
POWER OUTPUTS
iP1515.....................Six NEMA 5/15R (controlled), one NEMA 5/15R (unswitched)
iP1520.....................Six NEMA 5/20R (controlled), one NEMA 5/20R (unswitched)
NUMBER OF CONTROLLABLE PODS……………………………………………………..Three
RELAY CURRENT RATING (amps).....................................……………………………........30
POWER LINE FILTRATION...………………………………Multi-stage Filter (48dB at 30 MHz) MICROCONTROLLER………………………………………..…...……..Microchip PIC18F97J60 COMMUNICATIONS LINES
Ethernet (Network)………….......................................................……RJ-45 (8 Wire)
RS232................................................................................................RJ-11 (3 Wire)
COMMUNICATIONS PROTOCOL..................................................HTML, TCP, UDP, RS232
MONTIOR FEATURES
Front Panel.............................................Power On and Network Connection LEDs
Web Based.......................................Outlet On, Sequence Delay and Current Flow
( Additional web based control features are described in this Manual.) OPERATING TEMPERATURE RANGE (degrees Fahrenheit)
Operating....................................................................................................32 to 158
Storage......................................................................................................-40 to 185
FRONT PANEL FEATURES
ROCKER SWITCH - The primary intent is for the iP15 to be controlled via a re­mote RS232 or Ethernet link. This switch serves as a fail safe control device in the event a remote RS232 or Ethernet connection is not available or functioning. Mov­ing this switch to the UP position will cause the iP15 to turn on the three power PODs in a prescribed timed sequence. The default timing is two seconds between each POD activation. This timing can be changed by accessing the on board web server. Moving this switch to the DOWN position will cause the unit to turn off the POD outlets in the reverse order.
RECESSED SLIDE SWITCH - As a second fail safe control point, this switch can be used to manually turn on all POD outlets in the u nlikely event of failure of the control circuitry contained in the iP15. This switch will turn on all POD outlets si­multaneously. When the switch is returned to it’s “off” posit ion the iP15 will revert to the prior state the unit was in.
NETWORK LED - This LED will light up solid when the iP15 is connected to an
Page 3
Ethernet network connection. It will blink quickly when an Ethernet cable is at­tached but no network can be found. When no network cable is connected or when using RS232 the light will blink slowly indicating the unit is powered up.
POD LEDs - As each of the POD duplex receptacles on the back of the iP15 turns on a corresponding LED on the front of the unit will light. Each LED will turn off when the POD turns off.
BACK PANEL FEATURES
NETWORK (Ethernet) PORT - This RJ45 connector is for connecting to your PC, router or local area network using a TCP/IP link.
RS232 PORT- This RJ11 connector can be used for remote control of the iP15 via RS232 protocol over distances not to exceed 50 feet.
PODs 1 -3 - There are three duplex receptacles on the ba ck of the iP15. Each is rated for a maximum twenty amp load and each is controllable to turn on or off independently of the others. When the on board sequencing process is used POD 1 will turn on first, followed in order by POD 2 and POD 3. They will turn of in reverse order using this same process.
UNSWITCHED OUTLET - This single outlet is rated for a maximum load of fifteen amps on the iP1515 and twenty amps on the iP1520. It will have po wer any time the iP device is plugged into a live AC receptacle
.
Page 4
DETAILED INSTALLATION AND SETUP
Unbox the unit. The box contains: the iP15 unit, the iP15 manual and a war­ranty card .
Mount the iP15 in a 19” wide rack with metal mounting rails, designed with 1.75” spacing. Use appropriate rack mounting hardware. Always power the IP15 on a grounded outlet. Do not defeat the grounding feature of the iP15 power
cord.
SET UP DETAIL
Connecting to the iP15 using a Router.
1. Connect the iP15 to your network router using a Cat 5 cable plugged into the RJ45 “Network” port on the rear of the unit and the other end to your network router.
2. Plug the iP15 power cord into a live AC receptacle, such as a wall outlet. Note: The iP1520 requires a 20 amp, NEMA 5-20R receptacle.
3. The iP15 will take a few seconds to boot up and configure itself at which point the Network light on the front of the unit should illuminate and remain on without blinking, indicating network connectivity. If the Network light blinks check the cable connections.
4. Open a web browser on your PC and type in the following address on the navigation bar to access the iP15: http://juicegoose Be sure to type exactly as shown. No domain such as .com should be added:
5. You will be presented with the login box. Enter the following initial username and password (these can be changed later):
User: admin Password: juicegoose
Connecting to the iP15 using a Crossover CAT5/6 cable.
(recommended for advanced users only) To connect the iP15 to a PC directly you will need to change the properties of
your internet connection/IP address.
1. Plug the CROSSOVER cable into the PC network socket and the other end into the iP15 Network socket .
2. Plug the iP device power cord into a live AC receptacle, such as a wall outlet. Note: the iP1520 power cord requires a twenty amp, NEMA 5-20R, receptacle.
3. The iP15 device will take a few seconds to boot up and configure itself at
Page 5
which point the Network light on the front of the unit should illuminate and re­main on without blinking, indicating network connectivity. If the Network light blinks check the cable connections.
4. In Windows go to your start menu and navigate to the control panel. Then choose the Network Connections” icon.
5. Open Network connections by double clicking on it, select the LAN or HIGH­SPEED icon, right click on this and select properties.
6. Click once on the Internet Protocol item that you will see at the bottom of the list and select the properties button which is at the mid right.
7. Check the “Use the following IP address” box and then change the IP ad­dress to: 192.168.1.1, then change the Default Gateway address also to:
192.168.1.1.
8. Click OK and then close the network box.
9. Open a web browser on your PC and type in the following address on the navigation bar to access the iP15: 192.168.1.77.
10. The iP15 login box will appear, enter your login details and op erate the iP15.
You can also configure the required IP address and any network/RS232 set­tings you require using the RS232 connection. See page 14 for detailed RS232 commands and setup requirements.