OWNER’S
MANUAL
CQ SERIES
SEQUENCED POWER CONTROL
COVERS MODELS
CQ-1515TM, CQ-1520TM, CQ-1TM, CQ-2200TM,
CQ-3000TM and CQ-PD1-4TM
FEBRUARY 2015
File: 3176209DEN-001
Standard: UL508
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for any
losses, damage, or injury resulting directly or indirectly from the use of a CQ
Series device in a manner contrary to accepted safe operating methods or
any instructions contained in this document. The user should determine prior
to use whether this product is adequate, suitable and safe for the application
intended. Since individual applications can be subject to extreme variation
Juice Goose makes no representation or guarantee as to the suitability of a
CQ product for any generally described application.
CQ-SERIES
SEQUENCED POWER CONTROL SYSTEM
The Juice Goose CQ Series products are power distribution devices that will
control AC power application to multiple pieces of equipment. The primary intent of the design of this equipment is to power rack mounted audio or video
equipment with electric power current requirements of less than 15 amps, 20
amps or 30 amps depending on the CQ model being considered.
All CQ Series products can be remote activated. Several CQ devices can be
connected to form a power sequencing system that includes multiple circuits in
multiple locations.
SAFETY PRECAUTIONS
CQ Series products are designed to operate at 120 volts, 60 hertz. Operation
with any voltage or frequency other than that can damage the equipment and
create an unsafe situation.
CAUTION #1: All CQ devices must be grounded. If a power extension cord is
required, use a properly insulated and grounded cord. Failure to ground the
device could expose the user to dangerous electric shock.
CAUTION #2: All CQ devices should be installed only by qualified electrical
technicians using appropriate mounting hardware and correct installation techniques. When installing make sure main power is off before attaching the CQ
device. There are no user serviceable parts inside any of the CQ products.
CAUTION #3: Do not expose the CQ product to moisture or salty air. Doing so
could cause significant damage and create an unsafe condition.
PRÉCAUTIONS DE SÉCURITÉ
Série CQ produits sont conçus pour fonctionner à 120 volts, 60 hertz. Fonctionnement avec une tension ou une fréquence autre que celle qui peut endommager l'équipement et de créer une situation dangereuse.
ATTENTION #1 : CQ tous les périphériques doivent être mis à la terre. Si une
extension de cordon est nécessaire, utiliser un correctement isolés et cordon
mis à la terre. Échec à la masse le périphérique pourrait exposer l'utilisateur à
choc électrique.
ATTENTION #2 : Tous les périphériques CQ ne devrait être installé que par
des électriciens qualifiés avec matériel de montage approprié et correct techniques d'installation. Lors de l'installation assurez-vous que l'alimentation principale est hors tension avant de procéder à l'accrochage de la CQ périphérique.
Il n'y a aucune pièce réparable par l'utilisateur à l'intérieur des CQ produits.
ATTENTION #3 : Ne pas exposer le CQ produit de l'humidité ou air salé. Cela
pourrait causer des dommages importants et créer une situation dangereuse.
DETAIL SPECIFICATIONS
DIMENSIONS (H x W x D inches)
CQ 1515 & CQ 1520……..………………….…………….....….....………...1.72 x 19.00 x 7.00
CQ 1(Including 3 Gang Utility Box).............................................................4.50 x 6.50 x 3.75
CQ 2200 ................……………….......................……………………………5.50 x 6.40 x 3.75
CQ 3000.....................................................................................................9.00 x 6.00 x 4.00
CQ PD1-4.…..…………………………………………….....………………...32.00 x 3.50 x 2.00
WEIGHT (lbs)
CQ 1515 & CQ 1520….…………..…………………………...........................……………..10.0
CQ 1...................................................................................................................................1.0
CQ 2200 ................…………………………....…………………..............……………………4.0
CQ 3000.............................................................................................................................6.0
CQ PD1-4……………………………………............................................................……...15.0
CIRCUIT BREAKER
CQ 1515.........................................................................................Back Panel, 15A Thermal
CQ 1520………………………………………………........…………..Back Panel, 20A Thermal
CQ 1...............................................................................................................................None
CQ 2200………………................………………………..…………...Side Panel, 20A Thermal
CQ 3000………………………......…………………………………….Side Panel, 30A Thermal
CQ PD1-4…………………………………………………………………...………………….None
POWER INPUT
CQ1515……….........………..………....…Power Cord, 7 Foot, 14/3 SJTW with NEMA 5/15P
CQ1520……….........………..………....…Power Cord, 7 Foot, 12/3 SJTW with NEMA 5/20P
CQ 1.........................................................................................................................Hardwire
CQ 2200 .……….......................................…...Hardwire with Crimp Tight Fast-on Terminals
CQ 3000.....................................................................................Hardwire to Screw Terminal
CQ PD1-4……………….............................…………Hardwire with External 4’ Wire Harness
VOLTAGE INPUT.……………………………………………...……………...120 VAC at 60 Hz
POWER OUTPUTS
CQ 1515.…,,…..........…..Six NEMA 5/15R, Sequenced and One NEMA 5/15R Unswitched
CQ 1520.…,,…..........…..Six NEMA 5/20R, Sequenced and One NEMA 5/15R Unswitched
CQ 1...........................................................................................................Two NEMA 5/15R
CQ 2200……………………………………………….......…….Four NEMA 5/20R, Sequenced
CQ 3000.…....................................................................…..One NEMA L5/30R, Sequenced
CQ PD1-4..………………………………………………...…...Eight NEMA 5/20R, Sequenced
NUMBER OF SEQUENCE EVENTS
CQ 1515 & CQ 1520..………………………………………………………………………..Three
CQ 1.…………………………….......…………………………………………………………..One
CQ 2200……………………………….………………………………………………………...Two
CQ 3000……………………………….………………………………………………………...One
CQ PD1-4……………………………….……………………………………………………….Four
POWER LINE FILTRATION
CQ 1515 & CQ 1520……..……………..........……………Multi-stage Filter (48dB at 30 MHz)
VOLTAGE SPIKE PROTECTION
CQ 1515 & CQ 1520….………………………...…................………Triple MOV Matrix, L-N-G
COMMUNICATIONS LINE…........................……RJ-45 (See Owners Manual for Assembly)
MONITOR FEATURES………....................................................................Front Panel LEDs