JSW Pacific MAG11, MSTR51 User Manual

QUICK START GUIDE
KIT CONTENT
SYSTEM INTRODUCTION
Gateway
Smart wireless central home control / management center.
Panic Remote
Wireless multi-functional panic remote controller.
IP Camera
Wireless day / night portable motion alert indoor camera.
Gayway
IP Camera
Motion PIR
On / O Switch
Door / Window
Sensor
Indoor Siren
Panic Remote
Serie No.
x 1
Adaptor DC12V/1A
Adaptor DC 5V/1.5A
Battery AA 1.5V
NA
Battery CR2032 Sticky pad
Adaptor DC 5V/1 A Battery AA 1.5V
Battery CR2032
Ethernet cable 2M
x 1
Ethernet cable 2M
x 3 x 4 x 4
Sticky pad Screw
x 1 x 3 x 4
x 1 x 4 x 1
x 1
x 1
x 1
Screw
Bracket
Screw
?
x 2
Adaptor DC12V/1A
Motion PIR
Wireless portable / wall­mount area motion alert sensor.
Battery AA 1.5V x 3
Remove the insulating plastic
On / O Switch
Wireless appliance energy management power switch / signal repeater (single device)
Indoor Siren
Wireless portable / wall­mount alert siren.
Adaptor DC12V/1A
or Battery AA 1.5V x 4
Adaptor DC12V/1A
Door / Window Sensor
Wireless door / window access alert sensor.
Remove the insulating plastic
GETTING STARTED
1. Connect the gateway box to the Internet
(1) Connect gateway box to your router via the Ethernet cable. Then plug in the supplied power cable.
(2) The power LED indicator becomes steady RED and you will hear the gateway box beep twice. This means the gateway box is ready for APP setup.
(3) Launch 'OMGUARD SHC' APP. The APP will automatically search the available gateway box and brings up the system DID/password. If it is not shown, Please check the system DID on the bottom of the gateway box. Enter the system DID and default password 123456 manually.
Note: The gateway box should be powered on and connected to the Internet at all times.
You can continue to setup the camera and sensor(s) now.
2. Set up the IP Camera
(1) Connect the IP Camera to your router via the
Ethernet cable .
(2) Plug in the power adapter and wait until both RED
and GREED LED begin ashing.
Note: DO NOT begin the APP setup process until both
LEDs become steady on.
OMGUARDSHC
Steady RED
(3) Launch the 'OMGUARD SHC' APP. Click the 'ADD'
icon and choose 'Camera' to add the device to
system.
Follow the APP wizard setup process to add the camera.
Note: The APP will search the available IP Camera in
LAN area. If the camera you're setting doesn't appear in the searching list, please enter the camera ID (DID) and password manually.
Installing the IP Camera:
(1) Secure the camera stand on the stable surface.
(2) Mount the camera into camera stand. Adjust the
viewing angle and x the camera tightly.
3. Pair the Motion Sensor
Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon
and choose 'Motion Sensor' and to initiate the pairing process, following with pressing the pairing button located inside the battery compartment to complete the process.
Installing the Motion Sensor:
(1) Place the motion sensor upward, facing the location
to be monitored. The detection distance is up to 16 meteres.
For maximum coverage, it is recommanded to place the motion sensor highup with its back against the corner of walls to ensure best detection coverage.
(2) Use the double-sided tape to x the motion sensor.
OMGUARDSHC
OMGUARDSHC
16 meters
4. Pairing the Power Switch
Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon
and choose ‘Power Switch' and to initiate the
pairing process, following with press/hold the front panel button until LED ashing blue.
To initiate the repeater function, press / hold the front panel button turned orange, following with pressing the pairing button on the device .
5. Pairing the Door / Window Sensor
Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon
and choose 'Door Sensor' and to initiate the pairing process, following with removing and reinstalling the battery compartment cover to complete the process.
Installing the Door/Window Sensor
Using the double-sided tape:
(1) Apply the double-sided tape to the backs of the
Door/Window sensor.
(2) Select a location on the door/window. The large
piece of the sensor should be xed on the immovable frame of the door/window. Align the small piece to the large one. Fix the small piece on the movable part of the door/window frame.
(3) When it is nished, open the door or window to test
if the sensor has been correctly installed. You'll receive an alert from the mobile device if the APP and sensor have been corrected installed.
OMGUARDSHC
OMGUARDSHC
Using the mounting screws:
(1) Fix the rst mounting screw directly onto the door /
window frame (A). Place (hang) the larger piece on to the mounted screw, remove the battery compart
A
ment cover to x the second mounting screw (B).
(2) Open back cover of the small piece. Use the
mounting screws to x the back cover on the
Slot
movable part of the door/window frame (C). Mount the senor onto the back cover.
(3) When it is nished, open the door or window to test
if the sensor has been correctly installed. You'll
C
B
receive an alert from the mobile device if the APP and sensor have been corrected installed.
6. Indoor Siren
Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon
and choose 'Siren' and to initiate the pairing process, following with pressing the pairing button inside the battery compartment to complete the process.
Installing the Siren:
It is recommanded to install (wall-mount / place on at surface) the Siren in a highly visible location with minimum obsticles near for maximum visual and sound alert deterrence in critical situations. A/C power option is available, choose a suitable power outlet location for the installation.
OMGUARDSHC
7. Pairing the Remote Control
Launch the 'OMGUARD SHC' APP. Click the 'ADD' icon
and choose 'Panic Remote' and to initiate the
pairing process, following with press/hold the camera
button until the LED ashing blue.
8. APP Operation
Display device status in realtime. Tap "Status" to refresh the status page.
Setup groups of devices for instant function activation / deactivation.
1. Choose "+" to start a new "control".
2. Naming the control and select device(s).
3. Save.
Setup various scenarios for system to launch pre­congured settings governing the behaviour of lights, cameras and sirens.
1. Choose a device (initiator) from the list.
2. Choose "+" to add additional device (follower). Repeat to add additional device(s).
3. Save.
Example: "Motion PIR" (initator) > "Power Switch" (follower) > "Save".
Group
Scenario
OMGUARDSHC
Status
List of triggered events from device(s) and playback from camera(s).
Events
STATUS INDICATOR
ON
Sensor On
Sensor Triggered
1
Vandal Alert
2
Edit Mode
3
FCC Compliance Statement: This device complies with Part 15 of the FCC rules. Operation is subjected to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that
1
2
3
may cause undesired operation.
Products with CE Marking comply with EMC Directive (2004/108/EC); Low Voltage Directive (73/23/EEC); R&TTE (1999/5/EC); ROHS Directive (2011/65/EU) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms: EMC: EN 301 489 LVD: EN 60950 Radio: EN 300 328
OFF
Sensor O
Power Low
Delete
If the camera system no longer functions or can no longer be repaired, it must be disposed of according to the valid statutory regulations. Disposal of spent batteries/accumulators:
You are required by law (Battery Ordinance) to return all spent batteries and accumulators. Disposing of spent batteries/accumulators with common household waste is prohibited! Batteries/accumulators that contain hazardous substances are marked with the symbols on the side. These symbols indicate that it is prohibited to dispose of these batteries/accumulators in the household waste. The abbreviations for the respective heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead. You can return spent batteries and accumulators that can no longer be charged to the designated collection points in your community, outlets or wherever batteries or accumulators are sold. Following these instructions will allow you to fulll the legal requirements and contribute to the protection of our environment!
Loading...
+ 1 hidden pages