Joslyn Clark USAVAC - Vacuum Control Modifications

11
Low
USAVAC - Vacuum Control Modifications
Voltage
Modifications For Combination and Non-Combination Controllers
A
Description
Cover Controls
Push Buttons & Selector Switches Hand-Off-Auto Selector Switch Start-Stop Push Buttons 2 or 3 Position Selector Switch - SPDT Forward-Reverse-Stop Push Buttons High-Low-Stop Push Buttons Fast-Slow-Stop Push Buttons
Pilot LightsWithout Electrical Interlock:
With Electrical Interlock: Standard Transformer Type, Red Lens Push-to-Test Transformer Type, Red Lens Modification 11-14. Lens color below. Example: Order 11 + 15 = Std. Transformer with interlock & color lens
Green Blue White Yellow Amber Clear
Auxiliary Relays
Control Relay 4 Pole Maximum 2 N.O., 2 N.C. Time Relay ON Delay Time Relay OFF Delay Time Relay ON Delay & Instantaneous Time Relay OFF Delay & Instantaneous Time Relay ON Delay & OFF Delay
Enclosure Type NEMA 1, 3, 3R, 4, 12
264.
$
264.
480.
324.
504.
N/C N/C N/C N/C N/C N/C
560.
922.
922.
1032.
1032.
1169.
Change Cat. No. Character Indicated To:
B C
B C
C
11
13 14
13+15 13+16 13+17 13+18 13+19 13+20
21 22 23 24 25 26
Typical Catalog Number
V S18 A A 50690 - 76- ( )
Ordering & Pricing Example:
VS18TA350694-76 with the following modifications:
1 - Transformer operated Red Pilot with Interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 - Transformer operated Green Pilot Light with Interlock . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VS18TA350694-76
B
13
13 + 15
6863.
264.
324. + 324. $ 7775. Total
Discount Schedule JC11 A37
3 7 5
A
28 29
Low
Modifications Vacuum Control - USAVAC
Voltage
Modifications
Change Cat. No. Character Indicated To:
Description
Price
Overload Relay
$
777 Electronic Motor Management Relay 970 1775. 27 RM 2000 motor Monitor for use with 777 695. 27A
DEDUCT
28
29
Power Circuit
Standard Capacity - Primary Volts/Hertz:
220-240/60 or 220/50 440-480/60 or 440/50 550-600/60 or 550/50 200-208/60 380/50 220/25 440/25 100 Watts Extra - Primary Volts/Hertz: 220-240/60 or 220/50 440-480/60 or 440/50 550-600/60 or 550/50 200-208/60 380/50 220/25 440/25 Fused Primary (Includes 2 Fuses) Control Circuit Separate Fused Control Circuit, 2 fuses included
3 Phase Voltage Monitor Relay (Phase loss, Phase reversal)
3 Phase Voltage Monitor Relay, Phase loss, Phase reversal
Ammeter & 1-Current Transformer Ammeter, Switch, & 3-Current Transformers
Digital Power Meter
Voltmeter 3 Phase
* Ammeter 3 Phase
Voltmeter & Switch 3 Phase
* Voltmeter 3 Phase
Elapsed Time Meter
* Power (KW) Wattmeter
Wattmeter
* Energy (KWH) KWH Meter
Watthour Meter
* PF Meter
Operations Counter 8 Digit
* Frequency Meter
Space Heater with N.C. Auxiliary
* Reactive Power (KVAR)
Contactors without Power Wire
Contactors MI 320/160A 3 Phase Contactors MI 600/320A 3 Phase
* Digital Power Meter: All functions included in Mod. 35A
747.
1021.
1120.
966.
1449.
242. N/C
242.
2141.
1700.
1700.
1700.
48.
3331.
348.
604.
N/C
----
----
3
-T26
-T46
-T56
-T86
-T35
-T22
-T42
-C26
-C46
-C56
-C86
-C35
-C22
-C42 30 31 32 33A
35A
See page A22 See page A22
Typical Catalog Number
VS 18 A A 3 1 6 0 3 - 46 -( )
4 7 5
Ordering & Pricing Example:
VS18TA350694-76 with the following modifications:
1 - 3 Phase Voltage Monitor Relay (Phase loss, Phase reversal) . . . . . . . . . . . . . . . . . . .
Complete Cat# VS18TA350694-76-33A . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VS18TA350694-76
33A
6863.
+2141. $ 9004. Total