Joslyn Clark DC Control Accessories Catalog

5DP6 Accessories DC Control
J
Contact Kits - 5DP
1
Contactor Type
7000, 10/40A 5M19 $83. 5M20 $83. 7001 40A 5DP1 30A 5M55 83. 5M57 90. 5DP2 56A 5M52 173. 5M58 248. 5DP7 75A 5999-2521 131. 5M48 166. 5DP3A 110A 5M80A 207. 5M58 248. 5DP3 110A 5M53 207. 5M49 228. 5DP4 180A 5M54 386. 5M49 228. 5DP9 260A 5M56 552. 5M49 228. 5DP5 360A 5M-045 803. 5999-2461 580. 5DP8 535A 5999-2371 1012. 5999-2461 580. 5DP6 700A 5999-2381 1553. 5999-2481 1553.
Rating
DC Power Pack Kits - AC Coils
Rating
5DP6
700 amp.
NOTE: For all DC Coils up to 260 Amp add $221., for 360 & 535 Amp. add $359., 700 Amp. deduct ­$552.00
Contact Ratings
Type & Rating
7000
10/40 amp.
7001
40 amp. 5DP1 30 amp.
5DP2
56 amp.
5DP7
75 amp.
5DP3 5DP3A
110 amp.
Poles
N.O. Contact N.C. Contact Kit No. Price
2
5
Volts 60Hz
120 240 480
K i t N o . P r i c e 5999-8061
5999-8062 5999-8063
Kit No. Price
621.
$
621.
621.
Auxiliary Contact Rating
AC Amperes Volts Continuous Inrush 120 6 60 280 3 30 480 1.5 15 600 1.2 12
N.O. Contacts N.C. Contacts (intermittent duty)
240V 500V
2
----
2
4 0
2
4 0
1
3 0
2
3 0
1
5 6
2
5 6
2
7 5
1
110
2
110
1 0
---­ 4 0
3 0 3 0 5 6 5 6 7 5
---­110
10/40 Thru 100A
Dynamic Brake Make Only ­500V Max.
2 0 80(240V) 7 0
5 4
----­ 1 0 5
----­ 1 5 0
3 1 5
-----
DC Contact Rating - Amperes
Jogging Break Only 160V Max.
7 27(80V) 2 3
2 0
---­ 3 5
---­ 5 0
105
----
Coil Kits - 5DP (AC)
Rating
7000
10/40 A
7001
40A
5DP1 3 0 A 5DP2 5 6 A 5DP3A
110A
5DP7 7 5 A
5DP3 110A 5DP4 180A 5DP9 260A
5DP5 360A
5DP8 535 A
4,5, 6
5DP6
700A
Type & Rating
5DP4
180 amp.
5DP9
260 amp.
5DP5
360 amp.
5DP8
535 amp.
5DP6
700 amp.
Volts 50/60Hz
120 208 240 480 600 120 240 480 600 120 208 240 480 600 120
208/240
480 600 120
208/240
480 600 120
208/220
480 120V DC 240V DC (1-pole N.O.) 240V DC (for 1-pole N.C.; 2-pole N.C.; 2-pole N.O. 2-pole N.O. & 1-pole N.C)
7
Poles
1
2
1
2
1
2
1
2
1
2
V.A. -60Hz (Approx)
Inrush Sealed 120 120 120 120 120 234 264 245 246 290 290 290 290 290 672 672 672 683 1725 1750 1776 1782 566 530 528
N.O. Contacts N.C. Contacts (intermittent duty)
240V 500V
180 180
---­260 360 360
---­535 700 700
2 8 2 8 2 8 2 8 2 8 3 6 4 1 3 7
36.6 4 8 4 8 4 8 4 8 4 8
62.4
69.6
67.2 7 2 151 138 144 145 187 156 177
---­180
---­260 360 360
---­535 700 700
Kit No . Price 5ML25
5ML26 5ML29 5ML27 5ML28 5ML21 5ML22 5ML23 5ML24 5999-1801 5999-1805 5999-1802 5999-1803 5999-1804 5ML41 5ML42 5ML43 5ML44 5ML51 5ML52 5ML53 5ML54 5999-1601 5999-1604 5999-1602 5999-1601 5999-1602 5999-1602 5999-1602 5999-1603
Dynamic Brake Make Only ­500V Max.
3 1 5
----­ 387
----­ 720
----­1070
----­1400
-----
3
Jogging Break Only 160V Max.
105
---­135
---­240
---­356
---­466
----
$
53.
53.
53.
53.
53.
110.
110.
110.
110.
76.
76.
76.
76.
76.
156.
156.
156.
156.
322.
322.
322.
322.
1656.
2185.
2185.
1656.
2185.
2185.
2185.
2185.
Note:
1.
Contact Kits for 1-pole include stationary contacts, movable contacts and contact spring except as noted for 700 amp. size.
2.
Assembled kit for 1-pole including yoke with movable contacts and springs; stationary contacts.
3.
For all pole combinations except 2-pole N.C.
4.
These coils are for exact replacement at operating voltage and frequency listed.
Power pack assembly kit includes rectifier, economizing resistor and
5. terminal block. Power Pack Kit must be used on all DC operated 5DP6 units
Values measured at rectifier power pack input.
6. It is necessary to phase back the SCR's so that contactor normally
7. does not interrupt appreciable current. Contactors with blowouts and 2 N.O. contacts will interupt 200% current under abnormal conditions.
J6 Discount Schedule JC27