Identification
Identifying a Vital 1 safety module
When install ed in an electrical cabinet , the easiest way to identify a Vital 1 unit is by checking the front panel, where the product name is printed as shown in the picture below.
The article number for all versions of the Vital 1 safety module is 20-052-00. The article number (printed as
2005200), model version and produc t na m e can all be found on the label at the side of the unit, as shown in the picture below.
ABB AB / Jokab Safety Var labergsvägen 11, S-434 39, Sweden
www.jokabsafety.com
Identifying different Vital 1 versions
Version B
Version E
Version C
Version F
Version F2
Version G
Enclosure 1 - Pr oduct id entification draft_110510a 2 www.jokabsafety.com
Instructions
Vital 1
Testing the safety functions
General inform ation
Checking the safety functions of Vital 1 is normally easy to perform at a machine where V ital 1 is in operation. Do not disconnect the VITAL 1 for testing. This should only take a few minutes. The normal check is performed by using the safety devices connected to Vital 1 to verify that the safety functions are working properly. Proper functionality is indicated by the LEDs on the f ront panel of Vital 1. Specifi cally, LEDs #2 and #4 (marked with red circles in the pictures below) indi cate the status of the safety outputs.
Instructions
1 ) When power is supplied and all safety devices
connected to Vit al 1 are un-interrupted (i.e. the safety circuit is closed), all five LEDs on the front panel should be turned ON, as shown in the picture below.
2 ) Interrupt any of the safety devices connected to the
Vital 1 unit. Both safety outputs should then be deactivated. LEDs #2 and 4 indicate the status of the safety output s and should now be turned OFF. The state of the LEDs should be the same as either of the two pictures below.
In this state, the machine/process is allowed to start. In this state, the machine/process is stopped by Vital 1.
If either LED #2 or LED #4 is sti ll turned ON when the safety circuit is interrupted, the safety outputs are not functioning properly and the unit may not be put back into operation.
ABB AB / Jokab Safety Var labergsvägen 11, S-434 39, Sweden