Jokab Safety Smile Tina Data Sheet

CE RTIF IED BY
Emergency stop with indication
Approvals:
Smile Tina
Application:
To stop a machine or a process
Features:
Emergency push button up to cat. 4/PL e acc. to EN ISO 13849-1
Light grids, emergency stop and Eden in the same safety loop together with Vital or Pluto gives cat. 4/PL e acc.
to EN ISO 13849-1
With LED indication on push button
Robust Info-signal from each
emergency stop
Smile Tina - small and cost effective E-stop
In order to fulfil the need for a small and easy to install E-stop, Smile has been developed. The size of the device makes it pos­sible to be installed wherever you want. With M12 connections or cable and centralised mounting holes Smile is very easy to install, especially on aluminium extrusions. Smile is available for E-stops in both dynamic and static safety circuits i.e. for interfacing to Vital system/Pluto safety PLC and Safety relays. Each version is avail­able with either one or two M12 connections or cable. Two M12 connectors are used to enable the connection of E-stops in series, which is often used with dynamic safety circuits fulfilling safety category 4. In the top of the Smile Tina E-stop unit, LEDs show the actual status according to the dynamic system:
Green = everything is OK, Red = E-stop activated. Flashing Red/Green = Stop activated from another preceding de-
vice. Smile is also available with black push button and used as a safety stop. See section on safety stops.
The Smile Tina emergency stop is available in four ver­sions:
1. Smile 10EA Tina has a 1 m cable connected via the base of the unit.
2. Smile 11EA Tina has a five-pole M12 connector on the end of the unit for connecting the ABB Jokab Safety cable.
3. Smile 12EA Tina has two five-pole M12 connectors, one on each end of the unit for connecting the ABB Jokab Safety cable.
4. Smile 11EAR Tina has one 5-pole M12 connector at one end for connection of cable from ABB Jokab Safety.
Push button IP 65, housing IP67
Available as safety stop (black push button)
1
2
3
4
11:10
www.jokabsafety.com
T
R
IQ10
I0
A B
C
T
R
IQ10
I0
A
B
C
T
R
IQ10
I0
T
R
IQ10
I0
M12-3A M12-3A
M12-3B
T
R
3
2
1
4
T
R
IQ10
I0
C
B
A
Connection examples – Smile Tina
Smile 10EA Tina can be connected to either a Pluto or Vital system. Safety circuit cat-
egory 4 with LED indication/information. The connection cable exits from underneath the unit.
Pluto Vital
1
2
Smile 10EA Tina
Smile 11EA Tina can be connected to either a Pluto or Vital system. Safety circuit category
4 with LED indication/information. Connection via M12 connectors. The circuit below shows three Smile 11EA Tina units connected in series via connection terminals in the electrical cabinet.
Electrical cabinet
Pluto Vital
Smile 11EA Tina
Smile 11EA Tina
Connection termination
Smile 11EA Tina
3
4
5
6
7
8
Smile 11EA Tina can be connected to either a Pluto or Vital system. Safety circuit category 4 with LED indication/information. Connection via M12 connectors. The circuit below shows three Smile 11EA Tina units and one Eden connected in series via a Tina 4A connection block.
9
10
Smile 11EA Tina
Pluto
Vital
Tina 4A
11
Smile 11EA Tina
Smile 11EA Tina
Eden = Adam & Eva