2–20
SAFETY PRODUCTS CATALOG ABB JOKAB SAFETY
—
Ordering information
Vital
2
—
Description
DYNlink circuits Maximum DYNlink devices Safe outputs Typ e Order code
Vital 1
Tina 2A
2TLC010101V0201
1 30 2 NO Vital 1
—
Tina adaptation units to DYNlink
The Tina devices adapt the DYNlink signals from Pluto to safety components with mechanical
contacts, such as E-stops, switches and light beams/curtains with dual outputs. Tina is available
in several versions depending on the type of safety component that is connected to the
DYNlink solution. Also available is connector blocks and a blind plug.
Type of safety
device
Devices with positively driven force-
2TLC172453F0201
guided contacts like
E-stop buttons and
key switches
Type of connection to
Description Typ e Order code
the DYNlink loop
Via the device connection Mounted directly on the device enclosure to
a M20 cable entry.
Placed inside the safety device enclosure Tina 2B 2TLA020054R1100
M12-5 male connector Mounted directly on the device enclosure to
Tina 2A 2TLA020054R0100
Tina 3A 2TLA020054R0200
2TLA020052R1000
a M20 cable entry.
M12-5 male connector with
extra conductor for the
Two circuits and with supply voltage for the
safety sensor. Connects to a M20 cable entry.
Tina 3Aps 2TLA020054R1400
supply of the safety device
2TLC172457F0201
Tina 2B
Devices with OSSD
outputs like Orion
light guards
2TLC172459F0201
Tina 3A
Safety mats, edges
and bumpers with
Removable terminal
blocks
Mounted on a DIN rail in the electrical cabinet. Note that the connected safety device(s)
must be mounted on the same cabinet.
M12-5 male connector Adaptation of OSSD to DYNlink. Two M12
connectors.
Adaptation of OSSD to DYNlink with possibil-
ity to connect a local reset button. Three M12
connectors.
Adaptation of OSSD to DYNlink with possibility
to power the transmitter. Three M12 connectors.
M12-5 male connector Short-circuit detection and adaptation to
DYNlink.
Tina 7A 2TLA020054R0700
Tina 10A v2 2TLA020054R1210
Tina 10B v2 2TLA020054R1310
Tina 10C v2 2TLA020054R1610
Tina 6A 2TLA020054R0600
short-circuit detection
Tina 7A
Tina 10A
Tina 10B
Tina 6A
2TLC172469F0201
—
Connection blocks for serial connection of DYNlink devices (or devices with Tina adapter)
Description Type Order code
Connection block for the serial connection of up to 4 DYNlink devices with M12-5 connectors Tina 4A 2TLA020054R0300
Connection block for the serial connection of up to 8 DYNlink devices with M12-5 connectors Tina 8A 2TLA020054R0500
2TLC172473F0201
Connection block for the serial connection of two DYNlink devices with M12-5 connectors Tina 11A 2TLA020054R1700
Connection block for the serial connection of two DYNlink devices with M12-8 connectors, e.g.
Tina 12A 2TLA020054R1800
Magne.
2TLC172475F0201
—
Blind plug to complete the serial connection on a connection block
All M12 connectors on Tina 4A or Tina 8A must be connected to a safety dev ice or a Tina 1A. For
example, if only 6 devices are connected to a Tina 8A , two Tina 1A are necessary.
Description Typ e Order code
2TLC172467F0201
Tina 1A is a blind plug connected to the unused M12 connectors of the connection blocks Tina 4A
Tina 1A 2TLA020054R0000
and Tina 8A.