Safety timer
JSHT2
Approvals:
TÜV Nord
Safety relay for:
Time bypassing
Inching
Features:
Hardwire time selection
0.2 – 40 s
Selectable single or dual channel input
Test input
Width 45 mm
The JSHT2A/B/C closes two independent relay outputs during a guaranteed maximum period of time when the inputs are closed.
Time bypassing
Sensors detect the autocarrier and are connected to the JSHT2 which supervises the sensors and by pas ses the light beam for a maximum predeter mined time.
Inching
Inching applications require safety outputs to be closed for a predetermined maximum period of time, allowing the machine to move only a short distance each time the in­ching control is activated. For each new motion the inching control e.g. PB or pedal must be released and activated again.
Operation
When the inputs close the output contacts close. The out­put contacts open when the input opens or when the time period has expired. The time is hardwire selectable on the terminals T1, T2 and T3. The time given is the maximum time. Single or dual channel operation is also hardwire se­lectable.
LED indication for supply, inputs and outputs
1+1 NO relay outputs
Supply 24 VDC, 24, 48, 115 or 230 VAC
Quick release connector blocks
Connection examples
For examples of how our safety relays can solve various safety problems, please see the section “Connection examples”.
Regulations and standards
The JSHT2A/B/C is designed and approved in accordance with appropriate directives and standards. See technical data.
Light beam being bypassed only for the time it takes the
auto carrier to pass.
Shaft only turns a small amount each time the PB is pressed.
www.jokabsafety.com
6:33
Technical data – JSHT2 A/B/C
mm
1 2 0
7 4
45
Manufacturer ABB AB/Jokab Safety, Sweden Article number/Ordering data
JSHT2A 24 DC 2TLJ010012R0000 JSHT2B 24 DC 2TLJ010012R1000 JSHT2C 24 DC 2TLJ010012R2000
Colour Black and beige Power supply 24 VDC ± 15 %
Power consumption 1,8 W/3,8 VA Max Input Wire res. at nom
voltage/channel Response time at activation < 30 ms Response time at deactivation < 15 ms Selectable time
(± 15 % at nom. V.)
Relay outputs 2 x 1 NO Max. switching capacity
Resistive load AC 4A/250 VAC/10 00 VA Inductive load AC AC15 250VAC 3A Resistive load DC 4A/24 VD C/100 W Inductive load DC DC13 24VDC 2A
Max. total switching capacity: 8A distributed on all contacts Min. load 10m A /10 V (if load on contact has
Contact material AgCuNi Fuses Output (External) 3A gL/gG or 4A fast Max Input Wire res. at nom.
voltage 100 Ohm
24/48/115/230 VAC ± 15 %, 50 - 60 HZ
100/200 Ohm (1 Channel/ 2 Channel)
JSHT2A: 0.2 - 0.5 - 0.7 - 1.0 sec JSHT2B: 5 - 10 - 15 - 20 sec JSHT2C: 5 - 15 - 30 - 40 sec
not exceeded 100 mA)
Terminals (Max. screw torque 1 Nm)
Single strand: 1 x 4 mm2 or 2 x 1,5 mm Conductor with socket contact: 1 x 2,5 mm2 or 2 x 1 mm
Mounting 35 mm DIN-rail Protection class enclosure/
terminals IP 20/IP 40 IEC 60529 Impulse Withstand Voltage 2.5kV Pollution Degree 2 Operating temperature range –10°C to +55°C (with no icing or
Operating humidity range 35% to 85% LED indication Electrical Supply, Inputs, Outputs Weight 24 VDC: 310 g
Performance (max.)
Functional test: The relays must be cycled at least once a year.
Conformity 2006/42/EC, 2006/95/EC,
condensation)
24/48/115/230 VAC: 410 g. Safety Category 4/PL e (EN ISO
13849-1:2008) SIL 3 (EN 62061:2005) PFHd 4.42E-09
2004 /108/ EC EN 954-1:1996, EN 62061:2005 EN ISO 13849-1:2008
Connector blocks are detachable (without cables having to be disconnected)
2
2
1
2
3
4
5
6
Technical description – JSHT2 A/B/C
Connection and monitoring circuit
**
The electrical supply is connected across A1 and A2. The internal supervising circuit is activated directly when the supply is on. The inputs A and B must both be opened and then closed. Thereafter K1 and K2 are ac­tivated and the outputs close. K1 and K2 are activated for hardwired selected time
Timer
** Only for AC-supply.
(set by connections on the terminals T1, T2 and T3). If there is a short circuit bet­ween the inputs or the inputs are opened again before the set time period has expi­red the outputs will open. In order to close the outputs again both the inputs have to be opened and both internal relays K1 and
Electrical connection – JSHT2 A/B/C
7
8
K2 deactivated (controlled by the super­vising circuit) and then the inputs closed again. By external hardwire connectors the JSHT2 can be made to operate from either single or dual channel inputs. See figure below.
Connection for dual channel inputConnection for single channel input
9
10
11
Selection of time by hardwire links
JSHT2A JSHT2B JSHT2C
* It is recommended that all switched loads are adequately suppressed and/or fused in order to provide additional protection for the safety contacts. In the figure the monitoring of two contactors in the test input is shown.
12
13
14