Jokab Safety JSHT1 Catalog Page

www.jokabsafety.com
6:30
www.jokabsafety.com
Safety timer
JSHT1
Approvals:
TÜV Nord
Safety timer for:
Time reset
Time bypassing
Features:
Hardwire time selection 5 – 40 s
Selectable single or dual channel input
Test input
Width 45 mm
The JSHT1A/B closes two independent relay outputs during a guaranteed maximum time when the inputs are opened.
Time reset
Time reset can prevent uni ntentional reset of safety sys­tems when someone is still in the dangerous area of the machine. During a guaranteed maximum time, one or se­veral PB´s for reset must be activated. The reset buttons should be sited in such a way that operatives have a clear overview of the whole area which is guarded. Time reset is made by the combi nation of a safety relay and the timer relay JSHT1A/B.
Time bypassing
The JSHT1 can also be used for time bypass of light beams for e.g. autotruck into a dangerous area.
Operation
When the inputs open the output contacts close. The out­put contacts open when the inputs close or when the time period has expired. The time period is hardwire selectable on terminals T1, T2 and T3. The time given is the maximum time. One or two channel operation is also hardwire selec­table.
Regulations and standards
The JSHT1A/B is designed and approved in accordance with appropriate directives and standards. See technical data.
LED indication for supply, inputs and outputs
1+1 NO relay outputs
Supply 24 VDC, 24, 48, 115 or 230 VAC
Quick release connector blocks
Connection examples
For examples of how our safety relays can solve various safety problems, please see the section “Connection examples”.
1
2
Light beam being bypassed for a maximum pre-set time e.g. 5 sec. by the JSHT1 during entrance and exit with the JSHD4 Three Position Enabling device.
Time reset procedure. First push PB1, then exit dangerous area and close the door, then push PB2 (PB1 and PB2 must be pressed within the predetermined time pe­riod selected). After this procedure the machine can be safely restarted.
www.jokabsafety.com
6:31
Technical data – JSHT1 A/B
mm
1 2 0
7 4
45
Manufacturer ABB AB/Jokab Safety, Sweden Article number/Ordering data
JSH T1A 24 DC 2TLJ010011R0000 JSH T1B 24 DC 2TLJ010011R1000
Colour Black and beige Power supply 24 VDC ± 15 %,
Power consumption 1,8 W/3,7 VA Max Input Wire res. at nom
voltage/channel Response time at activation <30ms Response time at deactivation < 15 ms Selectable time
(± 15 % at nom. V.) Relay outputs 2 x 1 NO
Max. switching capacity Resistive load AC 4A/250 VAC/10 00 VA Inductive load AC AC15 250VAC 3A Resistive load DC 4A/24 VD C/100 W Inductive load DC DC13 24VDC 2A
Max. total switching capacity: 8A distributed on all contacts Min. load 10m A /10 V (if load on contact has
Contact material AgCuNi Fuses Output (External) 3A gL/gG or 4A fast Conditional short-circuit current
(1 kA) 6A gG Max Input Wire res. at nom.
voltage 100 Ohm
24/48/115/230 VAC ± 15 %, 50 - 60 Hz (AC versions JSHT1A only)
100/200 Ohm (1 Channel/ 2 Channel)
JSHT1A: 5-10-15-20 sec JSHT1B: 5-15-30-40 sec
not exceeded 100 mA)
Terminals (Max. screw torque 1 Nm)
Single strand: 1 x 4 mm2, 2 x 1,5 mm Conductor with socket contact: 1 x 2,5 mm2, 2 x 1 mm
Mounting 35 mm DIN-rail Protection class enclosure/
terminals IP20/IP40 IEC 60529 Impulse Withstand Voltage 2.5kV Pollution Degree 2 Operating temperature range –10°C to +55°C (with no icing or
Operating humidity range 35% to 85% LED indication Electrical Supply, Inputs, Outputs Weight 24 VDC: 330 g
Performance (max.)
Functional test: The relays must be cycled at least once a year.
Conformity 2006/42/EC, 2006/95/EC,
condensation)
24/48/115/230 VAC: 430 g Category 4 / PL e (EN ISO 13849-
1:2 008) SIL 3 (EN 62061:2005) PFHd 4.42E-09
2004 /108/ EC EN 954-1:1996, EN 62061:2005 EN ISO 13849-1:2008
Connector blocks are detachable (without cables having to be disconnected)
2
2
1
2
3
4
5
6
Technical description – JSHT1 A/B
Connection and monitoring circuit
**
The electrical supply is connected across A1 and A2. The internal supervising circuit is activated directly when the supply is on. The inputs A and B must both be closed and then opened. Thereafter K1 and K2
Timer
** Only for AC-supply.
are activated and the outputs close. K1 and K2 are activated for the hardwired selected time (set by connections on the terminals T1, T2 and T3). If there is a short circuit between the inputs or the inputs
Electrical connection – JSHT1 A/B
7
8
are closed again before the set time pe­riod has expired the outputs will open. In order to close the outputs again both the inputs have to be closed and both internal relays K1 and K2 deactivated (cont rol led by the super vising circuit) and the inputs again opened. By external hardwire connections the JSHT1 can be made single or dual chan­nel input. See figure below.
Connection for dual channel inputConnection for single channel input
9
10
11
Selection of time by hardwire links
JSHT1A JSHT1B
* It is recommended that all switched loads are adequately suppressed and/or fused in order to provide additional pro­tection for the safety contacts. In the figure the monitoring of two contactors in the test input is shown.
12
13
14
Loading...