Jokab Safety JSBR4 Catalog Page

Safety relay
JSBR4
Approvals:
TÜV Nord
Safety relay for:
Two-hand devices of type IIIc
Emergency stop
Three position devices
Interlocked Gates/Hatches
Contact strips
Safety mats
Foot operated switches
Features:
A universal relay for two-hand- and many other safety devices
The JSBR4 has two inputs, which both have to be closed to keep the safety output contacts closed. A short-circuit across the inputs will cause the output contacts to open. The inputs can however be subjected to a continuous short-circuit without damaging the safety relay. In order to make the safety outputs close the reset input must be closed and opened. In this way an unintentional reset is prevented in the case of a short-circuit in the reset button cable or if the button gets jammed in the actuated position. The reset input can also be used for test/super­vision to ensure that contactors or valves have returned to their initial off/stop position before a new start can be allowed by the safety relay. When the JSBR4 is used as a two-hand device relay, both buttons have to be pressed within 0.5 seconds of each other in order to close the outputs. When the JSBR4 is used for Safety Mats and Safety Strips the ”stop” condition is given following detection of a short-circuit between input channels A and B. The safety mat, safety strip or the relay will not be damaged by a con­tinuous short-circuit. This also gives the advantage that if there is a failure between the inputs in the installation, the safety relay will not be damaged.
Safety level
The JSBR4 has a twin supervised safety function. Com­ponent failure, short-circuit or external disturbance (e.g. loss of power supply) will not prevent the safe function of the relay. This is valid both for the inputs A and B as well as for the reset input. The JSBR4 operates at the highest safety level for safety relays (PL e according to EN ISO 13849-1).
Two channel with concurrency requirement of 0,5 s
Supervised reset
Test input
Width 45 mm
LED indication for supply, inputs and outputs
3 NO/1NC relay outputs
Supply 24 VDC, 24, 48, 115 or 230 VAC
Quick release connector blocks
Regulations and standards
The JSBR4 is designed and approved in accordance with appropriate directives and standards. See technical data. The JSBR4 complies with the highest safety level for the connection of a two-hand device of type IIIc in accordance with EN 574.
Connection examples
For examples of how our safety relays can solve various safety problems, please see the section “Connection examples”.
6:20
www.jokabsafety.com
Technical data – JSBR4
mm
1 2 0
7 4
45
Manufacturer ABB AB/Jokab Safety, Sweden Article number/Ordering data
24 DC 2TLJ010002R0000 24 AC 2TLJ010002R0200 115 AC 2TLJ010002R0400 230 AC 2TLJ010002R0500
Colour Black and beige Power supply 24 VDC ± 15%
Power consumption 1,3 W/3,3 VA Relay Outputs 3 NO + 1 NC Max. switching capacity
Resistive load AC 6A/250 VAC/1500 VA Inductive load AC AC15 240VAC 2A Resistive load DC 6A/24 VDC /150 W Inductive load DC DC13 24VDC 1A
Max. res. load total switching capacity: 12A distributed on all contacts
Min. load 10mA /10 V (if load on contact has
Contact material Ag + Au flash Fuses Output (External) 5A gL/gG Conditional short-circuit current
(1 kA) 6A gG Max. Input wire res. at nom.
voltage Response time at deactivation < 20 ms (145 ms at power loss)
24/48/115/230 VAC ± 15%, 50 ­60 Hz
not exceeded 100 mA)
300 Ohm (S13 - S14 and S23 ­S24)
Terminals (Max. screw torque 1 Nm)
Single strand: 1 x 2,5 mm2/2 x 1 mm2. Conductor with socket contact: 1 x 4 mm2/2 x 1,5 mm2.
Mounting 35 mm DIN-rail Protection class enclosure/
terminals IP 40/20 IEC 60529 Operating temperature range -10°C to +55°C (with no icing or
Impulse Withstand Voltage 2.5kV Pollution Degree 2 Operating humidity range 35% to 85% LED indication Electrical Supply, Inputs, Outputs Weight 350 g (24 VDC),
Values
(With Proof test interval 1 year)
Conformity 2006/42/EC, 2006/95/EC,
condensation)
460 g (24-230 VAC) Safety Category 4 according to
EN 954-1, PL e, SIL 3, PFHd 1.35E-08
2004 /108/ EC EN 954-1:1996, EN 62061:2005 EN ISO 13849-1:2008
Connector blocks are detachable (without cables having to be disconnected)
1
2
3
4
5
Technical description – JSBR4
Prot. circ.
Reset & Supervision circ.
*
* Only for AC-supply
The electrical supply is connected across A1 and A2. After Voltage reduction and Rectification (AC-versions) or reverse polarity protection (DC-version) there is an overload protection-circuit. When the inputs S13-S14 and S23-S24 have closed and the reset is made, the relays K1 and K2 are activated. A dual stop signal is given when K1 and
Electrical connection – JSBR4
K2 drop, due to short circuiting between the inputs, opening of the inputs or power failure. If one input is opened the other input must also be opened for K1 and K2 to be activated again. The monitoring circuit checks K1 and K2 and that the reset circuit to X2 is both closed and opened before K1 and K2 are energized. Both the stop and reset function therefore comply
with the requirement that a component fault, short circuit or external interference do not result in a dangerous function. The safety outputs consist of contacts from K1 and K2 connected internally in series across terminals 13 - 14, 23 -24 and 33 - 34. These contacts are used to cut the power to components which stop or prevent hazardous movements/functions. It is recommended that all switched loads are adequately suppressed and/or fused in order to provide additional protection for the safety contacts. Note: Output 41-42 is intended for indica- tion purposes only, e.g. gate opened. No load between S14 and S24 allowed.
6
7
8
9
10
Emergency stop with manual resetting.
Two hand device with buttons in separate or same enclosure. Buttons to be pressed in within 0.5 s of each other. Footpedal switches can be connected in the same configuration.
Interlocked gate with manual reset.
Enabling device, JSHD4. Stop condi­tion is given in both top and bottom PB positions.
www.jokabsafety.com
Contact mat/strip with manual reset.
Control and supervision of external con­ductor, relay, valve or ABB Jokab Safety’s expansion relays.
6:21
11
12
13
14
Loading...