Johnson Valves JV-E16 User Manual

Actuators & Actuated Valves
User Manual
JV-E
Electric 1/4 Turn Johnson Valves Actuator
20Nm - 1200Nm
The JV-E electric actuator is designed for quarter turn applications on ball and butterfly valves with bases to ISO 5211 & DIN 3337 standard. Small, lightweight and compact in design but still offering high output torques.
Simple Installation
All connections are located in a separate terminal box, minimising the amount of disassembly required.
Efficient Design
High torques are achieved with relatively low power consump-
Self Locking
The risk of overheating due to repeated operations is avoided with this feature.
High Visibility Position Indicator
Watertight Unit
IP68 Watertight (IP68 5m 120hr)
Captive Bolts
Bolts will not be lost even when the cover is open.
Standard Specifications
Enclosure IP68 Watertight (IP68 5m 120hr) Travel Angle 90o ± 5o
Power Supply 110V & 250V (1PH) / 24VDC / 380V & 440V (3PH) *** Casing Material Aluminium Alloy, Dry Power Polyester Coated
Indicator Dome Type Mechanical Terminal Block Push Button
Limit Switches 2 x Open / 2 x Close, SPDT, 250V AC * Ambient Temp -20 to +60oC
Inside Heater (AC Only) 1PH 110/220V AC ** Mechanism Scotch-Yoke (JV-E05 - Spur Gear Type)
* not available on JV-E02 ** not available on JV-E02, 04 & 05 ***Only available for JV-E16, 28, 40, 50, 80 & 120
ADDITIONAL DATA
Model Maximum Op. Time Rated Current (A) Motor Manual
No. Torque Output 50 / 60Hz AC (1PH) AC (3PH) DC Insulation / output Handle
0o 45o 90o 90o (sec.) 110V 220V 380V 440V 24V (AC . DC) Turns
JV-E02 20 20 20 17.5/14.5 0.29/0.25 0.12/0.1 N/A N/A 1.5 E . B/10W . 10W 3
JVE-04 40 40 40 12/10 0.67/0.6 0.23/0.2 N/A N/A 2 E . B/10W . 10W 3
JV-E05 50 50 50 13 N/A N/A 2 B . B/10W . 10W 18 (100-250V AC) 0.1-0.25
JV-E10 100 65 100 22/18 0.82/0.75 0.42/0.40 N/A N/A 2.5 F . B/10W . 15W 15
JV-E16 160 107 160 28/23 0.94/0.85 0.50/0.46 0.47/0.37 0.62/0.49 4 F . B/15W . 15W 19
JV-E28 280 190 280 40/33 0.94/0.85 0.50/0.46 0.47/0.37 0.62/0.49 4 F . B/15W . 15W 23
JV-E40 400 270 400 40/33 1.09/1.23 0.54/0.58 0.16/0.15 0.18/0.16 5.5 F . B/25W . 40W 23
JV-E50 500 350 500 40/33 1.55/1.75 0.72/0.90 0.30/0.28 0.40/0.30 N/A F/40W 23
JV-E80 800 540 800 51/42 1.97/2.83 1.09/1.46 0.50/0.54 0.57/0.55 N/A F/60W 77
JV-E120 1200 800 120 51/42 1.97/2.83 1.09/1.46 0.50/0.54 0.57/0.55 N/A F/90W 77
(s) spanner operated
JV-E USER MANUAL
- Table of Content -
1. Summary ……………………………………………………………………………………………… 1-1. Model System ……………………………………………………………………………………… 1-2. Label ……………………………………………………………………………………………
2. Products 2-1. Construction ………………………………………………………………………………………
3. Installation 3-1. Attachable Valve ……………………………………………………………………………… 3-2. Selection of Actuator ………………………………………………………………………… 3-3. Caution during Installation ………………………………………………………………………
4. Operation 4-1. Operation …………………………………………………………………………………………… 4-2. Limit Switch Setting …………………………………………………………………………… 4-3. Caution during Operation ………………………………………………………………………
5. Maintenance & Repair 5-1. Self-Diagnosis …………………………………………………………………………………… 5-2. Assembling & Disassembling …………………………………………………………………
6. Customer Service Support Contact ……………………………………………………………
Revision Date: 04/12/2015 Contents: Issued Issued: Lee Houghton
1. Summary
JV-E Actuator allows to conveniently open & close the Valve fast in any places wherever the electricity are connected & available. The Valve is designed to thoroughly assure the safety & convenience of users, however, please make sure to operate after reading & digesting the User Manual completely. Please check the homepage of Johnson Valves or inquire with Johnson Valves & authorized Agents for those items & subjects not described in the Manual.
- Data contained in the User Manual may be subject to change without advance notice for improvement of performance & safety of Product.
Did you receive the JV-E ELECTRIC ACTUATOR? Followings must be checked before operation.
1) It should be checked if the label is well attached, and if the specification of the label is the same with your order.
2) It should be checked if the connection diagram is attached at the inside of terminal cover.
3) It should be checked if the manual lever is attached at side or lower part.
4) It should be checked if there is any other scratch or dent.
1-1. Model System
Model number: Voltage: Serial Number: Rated current: Max torque: Nm Power: Op time (90): secs Output flange: Options:
This is the JV-E series user manual and each model is as follows.
JV-E05
JV-E = Johnson Valves Electric / 05 = Size & torque output
JV-E05 series (Spur gear) Torque graph
JV-E10 to 50 series (Scotch yoke) Torque graph
Temperature range = -20 to +60
1-2. Label
Models can be identified as labels with lot numbers and model numbers are attached to the products of Johnson valves as follows.
2. Products
2-1. Construction
Construction of the Product is illustrated as following.
Appearance based on JV-E16
Window
Cover Terminal block
Body Shaft Motor Cable entries ISO pad
Names of each parts based on JV-E16
Loading...