Johnson Controls VG1000 Series Data Sheet

Page 1
VG1000 Series Three-Way,
Spring-Return, Plated Brass
Ball and Stem Ball Valve Assemblies
without End Switches
VG1000 Series Valves with Non-Spring-Return Electric Actuator
Description
VG1000 Series Ball Valves are designed to regulate the flow of hot or chilled water and, for some models, low-pressure steam in response to the demand of a controller in HVAC systems. Available in sizes 1/2 through 2 in. (DN15 through DN50), this family of two- and three-way forged brass valves is factory or field mounted to Johnson Controls® VA9104, M9106, M9109, and M9100 Series Non-Spring-Return and VA9203 and VA9208 Series Spring-Return Electric Actuators for on/off, floating, or proportional control.
Refer to the VG1000 Series Forged Brass Ball Valves Product Bulletin (LIT-977132) for important product application information.
Features
• Forged Brass Body — provides 580 psig static pressure rating.
• 200 psi Closeoff Pressure Rating — provides tight shutoff.
Selection Charts
Three-Way Plated Brass Trim Ball Valves, Non-Spring Return, VA9104 Electric Actuators without Switches
Fluid Temperatures: 23 to 203°F (-5 to 95°C) Not Rated for Steam Service
Valve Size, in. Cv Closeoff
Actuators with M3 Screw Terminals VA9104-AGA-3S VA9104-IGA-3S VA9104-GGA-3S VG1841AD 1/2 1.2 VG1841AE 1.9 VG1841AF 2.9 VG1841AG 4.7 VG1841AL 7.4 VG1841AN 11.7 VG1841BG 3/4 4.7 VG1841BL 7.4 VG1841BN 11.7 VG1841CL 17.4 VG1841CN 11.7 VG1841CP 18.7 Actuators with 48 in. (1.2 m) 18 AWG Plenum Cable VA9104-AGA-2S VA9104-IGA-2S VA9104-GGA-2S VG1841AD 1/2 1.2 VG1841AE 1.9 VG1841AF 2.9 VG1841AG 4.7 VG1841AL 7.4 VG1841AN 11.7 VG1841BG 3/4 4.7 VG1841BL 7.4 VG1841BN 11.7 VG1841CL 17.4 VG1841CN 11.7 VG1841CP 18.7
1. To avoid excessive wear or drive time on the motor for the AGA models, use a controller or software that provides a timeout function to remove the signal at the end of rotation (stall).
2. Valve has a characterizing disk.
The performance specifications are nomina l and con form to accep table ind ustry stand ards. For applicati ons at con ditions be yond these specification s, consult th Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc.
Threaded Ball Valves and Actuators
Code No. LIT-1900229
Three-Way, Plated Brass Trim, NPT End Connections Ball
s
• 500:1 Rangeability — provides accurate control under all load conditions.
• Chrome-Plated Brass Ball and Stem Assembly Standard — handles both chilled and hot water applications with a fluid temperature range of 23 to 203°F (-5to95°C).
Repair Information
If the VG1000 Series Ball Valve fails to operate within its specifications, replace the valve body, actuator, or entire assembly. For replacement parts, contact the nearest Johnson Controls representative.
AC 24 V
psig
2
/ 0.7 / 1.2 / 1.9 / 2.9 / 4.7
/ 5.8 VG1841AN+9T4AGA VG1841AN+9T4IGA VG1841AN+9T4GGA / 2.9 / 4.7
/ 5.8 VG1841BN+9T4AGA VG1841BN+9T4IGA VG1841BN+9T4GGA / 4.7
/ 7.4
/ 9.4 VG1841CP+9T4AGA VG1841CP+9T4IGA VG1841CP+9T4GGA
/ 0.7 / 1.2 / 1.9 / 2.9 / 4.7
/ 5.8 VG1841AN+9A4AGA VG1841AN+9A4IGA VG1841AN+9A4GGA / 2.9 / 4.7
/ 5.8 VG1841BN+9A4AGA VG1841BN+9A4IGA VG1841BN+9A4GGA / 4.7
/ 7.4
/ 9.4 VG1841CP+9A4AGA VG1841CP+9A4IGA VG1841CP+9A4GGA
200 VG1841AD+9T4AGA VG1841AD+9T4IGA VG1841AD+9T4GGA
2 2 2 2
2
200 VG1841BG+9T4AGA VG1841BG+9T4IGA VG1841BG+9T4GGA
2
2
200 VG1841CL+9T4AGA VG1841CL+9T4IGA VG1841CL+9T4GGA
2
2
200 VG1841AD+9A4AGA VG1841AD+9A4IGA VG1841AD+9A4GGA
2 2 2 2
2
200 VG1841BG+9A4AGA VG1841BG+9A4IGA VG1841BG+9A4GGA
2
2
200 VG1841CL+9A4AGA VG1841CL+9A4IGA VG1841CL+9A4GGA
2
without Timeout
VG1841AE+9T4AGA VG1841AE+9T4IGA VG1841AE+9T4GGA VG1841AF+9T4AGA VG1841AF+9T4IGA VG1841AF+9T4GGA VG1841AG+9T4AGA VG1841AG+9T4IGA VG1841AG+9T4GGA VG1841AL+9T4AGA VG1841AL+9T4IGA VG1841AL+9T4GGA
VG1841BL+9T4AGA VG1841BL+9T4IGA VG1841BL+9T4GGA
VG1841CN+9T4AGA VG1841CN+9T4IGA VG1841CN+9T4GGA
VG1841AE+9A4AGA VG1841AE+9A4IGA VG1841AE+9A4GGA VG1841AF+9A4AGA VG1841AF+9A4IGA VG1841AF+9A4GGA VG1841AG+9A4AGA VG1841AG+9A4IGA VG1841AG+9A4GGA VG1841AL+9A4AGA VG1841AL+9A4IGA VG1841AL+9A4GGA
VG1841BL+9A4AGA VG1841BL+9A4IGA VG1841BL+9A4GGA
VG1841CN+9A4AGA VG1841CN+9A4IGA VG1841CN+9A4GGA
On/Off (Floating)
1
V–93
On/Off (Floating) with Timeout
0 to 10 VDC Proportional
Actuators
Actuators
Actuators
Actuators
Threaded Ball Valves and
Threaded Ball Valves and
Threaded Ball Valves and
Threaded Ball Valves and
Page 2
VG1000 Series Three-Way, Plated Brass Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators (Continued)
Three-Way Plated Brass Trim Ball Valves, Non-Spring Return, M9106 and M9109 Electric Actuators without Switches
Fluid Temperatures: 23 to 203°F (-5 to 95°C) Not Rated for Steam Service
Valve Size, in. Cv Closeoff
VG1841DN 1-1/4 11.7 / 7.4 VG1841DP 18.7 VG1841DR 29.2 VG1841EP 1-1/2 18.7 VG1841ER 29.2 VG1841ES 46.8 VG1841FR 229.2 VG1841FS 46.8 VG1841FT 73.7
1. To avoid excessive wear or drive time on the motor for the AGA models, use a controller or software that provides a timeout function t o remove the signal at the
2. Valve has a characterizing disk.
Three-Way Plated Brass Trim Ball Valves, Non-Spring Return, M9106 and M9109 Electric Actuators with Switches
Fluid Temperatures: 23 to 203°F (-5 to 95°C) Not Rated for Steam Service
Valve Size, in. Cv Closeoff
VG1841AD 1/2 1.2 / 0.7 VG1841AE 1.9 VG1841AF 2.9
Actuators
Actuators
VG1841AG 4.7 VG1841AL 7.4
Threaded Ball Valves and
Threaded Ball Valves and
VG1841AN 11.7 VG1841BG 3/4 4.7 VG1841BL 7.4 VG1841BN 11.7 VG1841CL 17.4 VG1841CN 11.7 VG1841CP 18.7 VG1841DN 1-1/4 11.7 VG1841DP 18.7 VG1841DR 29.2 VG1841EP 1-1/2 18.7 VG1841ER 29.2 VG1841ES 46.8 VG1841FR 229.2 VG1841FS 46.8 VG1841FT 73.7
1. To avoid excessive wear or drive time on the motor for the AGx models use a controller or software that provides a timeout function to remove the signal at the
2. Valve has a characterizing disk.
end of rotation (stall).
end of rotation (stall).
Threaded Ball Valves and Actuators
AC 24 V On/Off (Floating)
without Timeout
1
M9106-AGA-2
psig
2
200 VG1841DN+906AGA VG1841DN+906IGA VG1841DN+906GGA
2
/ 11.7
/ 14.6 VG1841DR+906AGA VG1841DR+906IGA VG1841DR+906GGA
2
/ 11.7
/ 18.7
/ 23.4 VG1841ES+906AGA VG1841ES+906IGA VG1841ES+906GGA
/ 18.7
/ 29.2
/ 36.8 VG1841FT+909AGA VG1841FT+909GGA
200 VG1841EP+906AGA VG1841EP+906IGA VG1841EP+906GGA
2
2
200 VG1841FR+909AGA VG1841FR+909GGA
2
M9109-AGA-2
VG1841DP+906AGA VG1841DP+906IGA VG1841DP+906GGA
VG1841ER+906AGA VG1841ER+906IGA VG1841ER+906GGA
VG1841FS+909AGA VG1841FS+909GGA
AC 24 V On/Off (Floating)
without Timeout
1
M9106-AGC-2
psig
2
200 VG1841AD+906AGC VG1841AD+906IGC VG1841AD+906GGC
2
/ 1.2
2
/ 1.9
2
/ 2.9
2
/ 4.7
/ 5.8 VG1841AN+906AGC VG1841AN+906IGC VG1841AN+906GGC
2
/ 2.9 / 4.7
/ 5.8 VG1841BN+906AGC VG1841BN+906IGC VG1841BN+906GGC / 4.7
/ 7.4
/ 9.4 VG1841CP+906AGC VG1841CP+906IGC VG1841CP+906GGC
/ 7.4
/ 11.7
/ 14.6 VG1841DR+906AGC VG1841DR+906IGC VG1841DR+906GGC
/ 11.7
/ 18.7
/ 23.4 VG1841ES+906AGC VG1841ES+906IGC VG1841ES+906GGC
/ 18.7
/ 29.2
/ 36.8 VG1841FT+909AGC VG1841FT+909GGC
200 VG1841BG+906AGC VG1841BG+906IGC VG1841BG+906GGC
2
2
200 VG1841CL+906AGC VG1841CL+906IGC VG1841CL+906GGC
2
2
200 VG1841DN+906AGC VG1841DN+906IGC VG1841DN+906GGC
2
2
200 VG1841EP+906AGC VG1841EP+906IGC V G1841EP+906GGC
2
2
200 VG1841FR+909AGC VG1841FR+909GGC
2
M9109-AGC-2
VG1841AE+906AGC VG1841AE+906IGC VG1841AE+906GGC VG1841AF+906AGC VG1841AF+906IGC VG1841AF+906GGC VG1841AG+906AGC VG1841AG+906IGC VG1841AG+906GGC VG1841AL+906AGC VG1841AL+906IGC VG1841AL+906GGC
VG1841BL+906AGC VG1841BL+906IGC VG1841BL+906GGC
VG1841CN+906AGC VG1841CN+906IGC VG1841CN+906GGC
VG1841DP+906AGC VG1841DP+906IGC VG1841DP+906GGC
VG1841ER+906AGC VG1841ER+906IGC VG1841ER+906GGC
VG1841FS+909AGC VG1841FS+909GGC
On/Off (Floating)
0 to 10 VDC Proportional
with Timeout M9106-IGA-2 M9106-GGA-2
M9109-GGA-2
On/Off (Floating)
0 to 10 VDC Proportional
with Timeout M9106-IGC-2 M9106-GGC-2
M9109-GGC-2
The performance specifications are nomina l and con form to accep table ind ustry stand ards. For applicati ons at con ditions be yond these specification s, consult th Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc.
V–94
Page 3
Threaded Ball Valves and Actuators
VG1000 Series Three-Way, Plated Brass Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators (Continued)
Technical Specifications
VG1000 Series Three-Way, Plated Brass Trim, NPT End Connections Ball Valves with Non-Spring-Return Electric Actuators
1
Service Valve Fluid Temperature Limits Water 23 to 203F (-5 to 95C)
Steam Not Rated for Steam Service
Maximum Actuator Fluid Temperature Limit
Valve Body Pressure Rating Water 580 psig (4,000 kPa) (PN40)
Maximum Closeoff Pressure 200 psid (1,378 kPa) Maximum Recommended Operating Pressure Drop 50 psid (340 kPa) Flow Characteristics Three-Way Equal Percentage Flow Characteristics of In-Line Port A (Coil) and Linear Flow Characteristics of
Rangeability Minimum Ambient Operating Temperature -4°F (-20°C) Maximum Ambient
Operating Temperature (Limited by the Actuator and Linkage)
2
203°F (95°C) VA9104
Steam Not Rated for Steam Service
140° (60°C) VA9104 Series Non-Spring-Return Actuators
Hot Water, Chilled Water, and 50/50 Glycol Solutions for HVAC Systems
M9104 with M9000-551 Linkage M9106 or M9109 with M9000-520 Linkage
Angle Port B (Bypass) Greater than 500:1
M9104 Series Non-Spring-Return Actuators with M9000-551 Linkage
125° (52°C) M9106 and M9109 Series Non-Spring-Return Actuators with M9000-520 Linkage
Leakage 0.01% of Maximum Flow per ANSI/FCI 70-2, Class 4 End Connections National Pipe Thread (NPT) Materials Body Forged Brass
Ball Chrome Plated Brass Blowout-Proof Stem Nickel Plated Brass Seats Graphite-Reinforced PTFE with Ethylene Propylene Diene Monomer (EPDM) O-Ring Backing Stem Seals EPDM Double O-Rings Characterizing Disk Amodel
1. Proper water treatment is recommended; refer to the VDI 2035 Guideline.
2. Rangeability is defined as the ratio of maximum controllable flow to minimum controllable flow.
® AS-1145HS Polyphthalamide Resin
Actuators
Actuators
Actuators
Actuators
Threaded Ball Valves and
Threaded Ball Valves and
Threaded Ball Valves and
Threaded Ball Valves and
The performance specifications are nomina l and con form to accep table ind ustry stand ards. For applicati ons at con ditions be yond these specification s, consult th Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2014 Johnson Controls, Inc.
V–95
Loading...