95.5% SINGLE STAGE
GAS-FIRED RESIDENTIAL
MULTI-POSITION GAS FURNACES
MODELS: GG9S
NA TURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the original purchaser; a 20-year limited warranty from original installation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial applications.
Standard 5-year limited Parts warranty.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
400995-UTG-D-0210
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV listed and may be vented either
through side wall or roof applications using approved plastic
combustion air and vent piping.
FEATURES
•Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
•Compact, easy to install, ideal height 33" tall cabinet.
•Blower-off delay for cooling SEER improvement.
•Easy access to controls to connect power/control wiring.
•Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
•Low unit amp requirement for easy replacement application.
•Single wire twinning or staging feature available.
•All models are convertable to use propane (LP) gas.
•Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
•100% shut off main gas valve for extra safety.
•4 speed, direct drive PSC motor.
•24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
2Johnson Controls Unitary Products
Approximate
Operating Weights
Min. wire Size
Amps
(awg) @ 75 ft
one way
400995-UTG-D-0210
NOTICE
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Performance” tables shown represents blower performance WITHOUT filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabinet. DO NOT attempt to install any filters inside the furnace.
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer ’s recommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes (High velocity 600 FPM)
CFM
800A16 x 2514 x 25
1000A16 x 2514 x 25
1200A16 x 2514 x 25
1200B16 x 2516 x 25
1600B16 x 2516 x 25
1600C16 x 2520 x 25
2000C(2) 16 x 2520 x 25
2200C(2) 16 x 2520 x 25
2000D(2) 16 x 2522 x 25
1. Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity filters.
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one return with a transition to allow use of a 20x25 filter.
Cabinet
Size
Side
(in)
Bottom
(in)
Unit Clearances to Combustibles
ApplicationUpflowDownflowHorizontal
Top 1" 0" 0"
Vent0" 0" 0"
Rear0" 0" 0"
Side0" 0" 1"
Front*0" 0" 0"
1
FloorCombustible
ClosetYesYesYes
Line ContactNoNoYes
1. For combustible floors only when used with special sub-base.
* - 24" clearance in front and 18" on side recommended for service access.
All furnaces approved for alcove and attic installation.
Combustible
Combustible
ACCESSORIES
Propane (LP) Conversion Kit - This accessory conversion kit
may be used to convert natural gas (N) units for propane (LP)
operation.
S1-1NP0347 - All Models except 130K Model
S1-1NP0501 - 130K Model
Concentric Vent Termination - For use through rooftop, sidewall. Allows combustion air to enter and exhaust to exit through
single common hole. Eliminates unslightly elbows for a cleane r
installation.
Sidewall Vent Termination Kit - For use on sidewall, two-pipe
installations only. Provide a more attractive termination for locations where the terminal is visable on the side of the home.
S1-1HT0901 (3")
S1-1HT0902 (2")
Condensate Neutralizer Kit - Neutralizer cartridge has a 1/2"
plastic tube fittings for installation in the drain line. Calcium carbonate refill media is also available from the Source 1 Parts (p/
n 026-30228-000).
1NK0301
Side Return Filter Racks -
S1-1SR0200 - All Models
S1-1SR0402 - All Models
Bottom Return Filter Racks - 1BR05xx series are galvanized
steel filter racks. 1BR06xx are pre-painted steel filter racks to
match the appearance of the furnace cabinet.
S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets
Combustible Floor Base Kit - For installation of these furnaces in downflow applications directly onto combustible flooring material, These kits are required to prevent potential
overheating situations.tible floor base kit provides access for
combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets
S1-1CB0524 - For 24-1/2” cabinets
EAC Transition Kits - For installation of EAC accessories with
these furnaces to provide easy transition of return airflow
through the EAC to get the proper sealing and reduced airflow
leakage.
S1-1TK1001 - For all models using side return
S1-1TK1014 - For 14-1/2” cabinets using bottom return
S1-1TK1017 - For 17-1/2” cabinets using bottom return
S1-1TK1021 - For 21” cabinets using bottom return
S1-1TK1024 - For 24-1/2” cabinets using bottom return
High Altitude Pressure Switches - For installation where the
altitude is less than 5,000 feet it is not required that the pressure switch be changed. For altitudes above 5,000 feet, see kits
below.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
Johnson Controls Unitary Products3
400995-UTG-D-0210
Blower Performance CFM - Any Position (without filter) - Bottom Return
ModelsSpeed
0.10.20.30.40.50.60.70.80.91.0
High 1128 1077 1035 996 950 891 842 781 708 646
GG9S040A08MP11
GG9S060A10MP11
GG9S060B12MP11
GG9S080B12MP11
GG9S080C16MP11
GG9S080C22MP11
GG9S100C16MP11
GG9S100C20MP11
GG9S120D16MP11
GG9S120D20MP11
GG9S130D20MP11
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V.
Medium High 934 909 867 834 818 780 745 696 631 584