Johnson Controls GG9S040A08MP11, GG9S080B12MP11, GG9S060A10MP11, GG9S060B12MP11, GG9S080C16MP11 Technical Manual

...
95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES
MODELS: GG9S
NA TURAL GAS 40 - 130 MBH INPUT
Due to continuous product improvement, specifications are subject to change without notice.
Visit us on the web at www.york.com Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig­inal purchaser; a 20-year limited warranty from original instal­lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli­cations.
Standard 5-year limited Parts warranty.
TECHNICAL GUIDE
TECHNICAL GUIDE
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
400995-UTG-D-0210
DESCRIPTION
These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.
These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and vent piping.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
Low unit amp requirement for easy replacement application.
Single wire twinning or staging feature available.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Secondary heat exchanger made of corrosion resistant stainless steel materials.
Timed on, adjustable off blower capability for maximum com­fort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Airflow leakage less than 1% of nominal airflow at duct­blaster conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and removal of blower.
External air filters used for maximum flexibility in meeting customers IAQ needs.
Protection included from air intake, exhaust vent, or conden­sate blockage.
Venting applications - may be installed as either 2-pipe (sealed combustion) or single-pipe vent (using indoor com­bustion air).
No special vent termination required.
1/4 turn knobs provided for easy door removal.
Internal condensate trap design (patent pending) provides condensate management options, easy visual operation, and is self-priming to prevent nuisance problems.
400995-UTG-D-0210
FRONT
33
A
LEFT SIDE
Combustion Air Inlet
Condensate Drain (Downflow)
Vent Outlet
Thermostat Wiring
28.5”
Gas Pipe Entry
Electrical Entry
Condensate Drain
Thermostat Wiring
RIGHT SIDE
Vent Outlet
Condensate Drain (Downflow)
14”
1”
1.5”
23”
Combustion Air Inlet
Gas Pipe Entry
Electrical Entry
Condensate Drain
Optional Return Air Cutout (Either side)
29.5”
C
SUPPLY END
.56”
.56”
20”
B
3”
23.8”
.56”
Combustion Air Inlet
Vent Outlet
RETURN END
B
24.25”
Cabinet & Duct Dimensions
Models
Nominal
CFM (m
3
/min)
Cabinet
Size
Cabinet Dimensions (Inches)
ABC Lbs
GG9S040A08MP11 800 A 14 1/2 13 3/8 11 3/4 113 GG9S060A10MP11 1000 A 14 1/2 13 3/8 11 3/4 118 GG9S060B12MP11 1200 B 17 1/2 16 3/8 13 1/4 122
GG9S080B12MP11 1200 B 17 1/2 16 3/8 14 3/4 126 GG9S080C16MP11 1600 C 21 19 7/8 16 1/2 136 GG9S080C22MP11 2200 C 21 19 7/8 16 1/2 139 GG9S100C16MP11 1600 C 21 19 7/8 18 1/4 142 GG9S100C20MP11 2000 C 21 19 7/8 18 1/4 145 GG9S120D16MP11 1600 D 24 1/2 23 3/8 21 3/4 153 GG9S120D20MP11 2000 D 24 1/2 23 3/8 21 3/4 156 GG9S130D20MP11 2000 D 24 1/2 23 3/8 No Hole 160
Ratings & Physical / Electrical Data
Models
GG9S040A08MP11 40 38 95.5 30-60 160 1/3 4.8 11x8 15 8.0 14 GG9S060A10MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 GG9S060B12MP11 60 57 95.5 30-60 160 1/2 7.1 11x8 15 10.0 14 GG9S080B12MP11 80 76 95.5 35-65 165 1/2 7.1 11x8 15 10.0 14 GG9S080C16MP11 80 76 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14 GG9S080C22MP11 80 76 95.5 35-65 165 1 14.5 11x11 20 17.0 12
Input Output
MBH MBH °F °F HP Amps
AFUE
%
Air Temp.
Rise
Max. Outlet
Air Temp
Blower
GG9S100C16MP11 100 95 95.5 35-65 165 3/4 8.8 11x10 15 11.5 14
Blower
Size
Over-Current
Max
Protect
Total Unit
GG9S100C20MP11 100 95 95.5 35-65 165 1 14.5 11x11 20 17.0 12 GG9S120D16MP11 120 114 95.5 40-70 170 3/4 8.8 11x10 15 11.5 14 GG9S120D20MP11 120 114 95.5 35-65 165 1 14.5 11x11 20 17.0 12 GG9S130D20MP11 130 123.5 95.5 45-75 175 1 14.5 11x11 20 17.0 12
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.
2 Johnson Controls Unitary Products
Approximate
Operating Weights
Min. wire Size
Amps
(awg) @ 75 ft
one way
Loading...