Description
The AS-XFR Series Transformer Module is a
UL Class 2 device used to power digital
controllers and input/ou tput loads. It provides
120 VAC to 24 VAC isolation. Three different
models are available (see selection chart
below), all of which include a spli t-bobbin for
added no is e im mu n it y and a manua lly resetable breaker on the secondary connection.
The secon dary co nnection includ es a modu lar
connector for use with AHU controllers and
Companion products. Ground wires are
electrically and mechanically connected to the
transformer frame.
The XFR100 is a 100 VA transformer
pre-mounted in an EN-ENC100 enclosure. It
includes a po w e r s wit c h and a utility outlet.
The enclosure can be vertically mounted with
a DIN rail or directl y mo un t e d to a wall, and
support s mul t ip le 3/4 in . and 1-1 /2 in. cond ui t
connections.
XFR100
The XFR010 is a 100 VA transformer without
an enclosure. It can be used in any
appropriate UL-listed enclosure and is used
as a replace ment transformer for the XFR100
or in EWC35/45 Series enclosures.
The XFR050 is a 50 VA tr ansfo rmer with out an
encl os ure. It can b e used in any appropriate
UL-listed enclosure and is used as a
replacement transformer for the EWC15/25
Series enclosures.
Features
• choice of 50 VA or 100 V A power r ating
• color- c od ed wir e le ads for simple
installation
• split-bobbin design for better noise
immunity
• resetable breaker on the secondary that
trips on s horts or over loads
Applications
XFR S er i es Tran sformers a r e us ed to power
digit al control le r s an d inp ut/outp ut load s. To
determine which transformer is correct for
your application, see mounting and wiring
instructions for individual controllers.
To Order
Specify the code number from the following
selection chart.
Selection Chart
Code Number
AS-XFR100-1 100 VA
AS-XFR010-1 100 VA
AS-XFR050-0 50 VA
Power
Rating
Voltage
120
Primary Secondary
Electrical
Connection
18 AMG, 12 in.,
black, white, green/yellow,
Stripped 3/8 in.
Specifications
AS-XFR Series Trans f ormer Module
Electrical Rating
Operating Conditions 0 to 50°C (32 to 120°F)
Agency Compliance UL 864/916 and CSA C22.2 No. 205
Agency Listings UL Listed and CSA Certified
AS-XFR100-1 6.75 in. x 7.38 in. x 4.63 in.
Dimensions H x W x D
Shipping Weight
AS-XFR010-1 3.75 in. x 3.75 in. x 3.50 in.
AS-XFR050-0 2.80 in. x 4.50 in. x 3.25 in.
AS-XFR100-1 3.05 kg (6.7lbs.)
AS-XFR010-1 2.15 kg (4.7 lbs.)
AS-XFR050-0 1.2 kg (2.6 lbs)
100 VA, primary, 120 VAC/60 Hz
secondary, 24 VAC/60 Hz
Voltage
24
Electrical
Enclosure
Connection
16 AMG, 20 in., brown, orange, MOLEX connector AS-ENC100
18 AMG, 20 in., brown, orange, green/yellow,
MOLEX connector
None
The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond t hese specifications, consult the local Johnson
Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products.
1/1
© 06/01 Johnson Controls, Inc