JMR electronic Fortra 5251F6 User Manual

I6 Infortrend 5251F6
15-bay Rackmount & Tower Enclosures
Installation Guide
October 22, 2003 • Revision A
Patent Pending
ii
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Copyright
Copyright 2003 by JMR Electronics, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the express written permission of JMR Electronics, Inc.
Sales and Ordering Information
JMR Electronics, Inc. 20400 Plummer Street Chatsworth, CA 91311 USA Phone: 818-993-4801 Fax: 818-993-9173 Office Hours: Monday-Friday 8:00 A.M. to 5:00 P.M., Pacific Standard Time
European Corporate Headquarters
JMR Electronics United Kingdom
Iain Pickthall P.O. Box 3058 Wokingham Berkshire - RG40 3FU - United Kingdom Phone: + 44-118-973-6018 Fax: + 44-118-973-7191 E-Mail: Iain@jmr.com
Internet: http://www.jmr.com
Trademarks
JMR, the JMR logo, and FORTRATMand StorBladeTMare registered trademarks of JMR Electronics, Inc. All other product and brand names are the property of their respective holders.
Changes
The material in this document is for information only and is subject to change without notice. JMR Electronics, Inc. reserves the right to make changes to this manual and the equipment described herein without notice. JMR has made all reasonable efforts to ensure that the information in this manual is accurate and complete. However, JMR shall not be liable for any technical or editorial errors or omissions made herein or for incidental, special, or consequential damage of whatsoever nature resulting from the furnishing of this manual, or operation and performance of equipment with this manual.
Disclaimer
The original product packaging has been tested and is safe under normal shipping circumstances. Reshipping the product without using the original product packaging will void the warranty. Do not ship the unit with canisters or power supplies installed as this will void the warranty and could cause damage to the unit and drives. The canisters should be packaged separately within the product packaging as provided.
FCC Information
The FORTRAand StorBladeTMequipment generates, uses and can radiate radio frequency energy. If the FORTRAor StorBladeTMArray is not installed and used properly (that is, in strict compliance with these
instructions), it may cause interference to radio and television reception. The FORTRAand StorBladeTMequipment and its contents are designed to comply with the limits for a Class
A computing device in accordance with the specifications in Part 15 of FCC rules. These rules are designed to provide reasonable protection against radio interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures are necessary to correct the interference.
Y ou may find the FCC booklet, How to Identify and Resolve Radio Interference Problems, helpful. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402. Stock #004-000-00345-4. Printed in the USA Part Number PUB-00296 Revision A, October 2003, SCS Patent Pending
WARNING: Changes or modifications, not expressly approved by the
manufacturer, could void the user's authority to use the equipment.
WARNUNG: Nicht ausdrücklich durch den Hersteller genehmigte Änderungen
oder Modifikationen können die Erlaubnis Zur benutzung der Produkte gefährden.
iii
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Table of Contents
1. Introduction
2/4/6/8/10/12/15-bay Product Family Features . . . . . . . . . . . . . . . . . . . . .1-1
Rackmount Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Tower Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Fibre Channel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Loop Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Loop Bypass and Clock Timing Circuit . . . . . . . . . . . . . . . . . . . . . . .1-3
ID Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
SES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
2. Hardware Specification
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Packaging Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2
Thermal Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Rotation Vibration Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Fault Indication Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
15-bay Fault Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
15-bay Audible Alert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
S-FLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
S-ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
3. Device Installation
SCA Connection and Hot-Swapping . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Canister Removal/Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
Drive Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2
4. Fibre Channel Setup
Slot Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1
ID Conflict . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Delayed Start Option Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Remote Start Option Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
Front Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3
External I/O Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
Host CH-0 and CH-1 (Bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
Table of
Contents
iv
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Host CH-0 and CH-1 (Top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
CH 2 (Bottom) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4
CH 3 (Top) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
CH 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
CH 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
RS232 Controller 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
RS232 Controller 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
5. Blower Operation
Blower Removal/Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1
Blower Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2
6. Power Supply Operation
Power Supply Removal/Insertion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-1
Low Power Mode (Standby Power) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2
Power Supply Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2
7. FR15 Cabinet Installation
Rail Mounting Kit Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
Spare Hardware Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
Rail Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2
8. SES Operation
9. Infortrend 5251F6 Installation
Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1
Default Slot ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1
10. Product Support
US Corporate Headquarters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-1
Manual Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-1
Appendix A. Drive and Controller Manufacturers
Drive Manufacturers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
RAID Controller Manufacturers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Host Bus Adapter Manufacturers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
The 15-bay FORTRAI6 Infortrend 5251F6 enclosures are designed to be used with a host system to provide a high-end RAID subsystem. The following is a summary of the 15-bay Rackmount and Tower enclosure features:
The 15-bay FORTRA
I6 Infortrend 5251F6 Tower enclosure supports up to fifteen LP SCA 40-pin SCA drives. This model supports up to six 2Gb/s Fibre Channel loops. The Fibre Channel enclosure has dual or quad fibre channel host ports and dual or quad fibre channel drive ports.
The 15-bay FORTRA
I6 Infortrend 5251F6 Rackmount is a 19" wide, 3U (5-1/4") high rackmount enclosure that supports up to fifteen LP SCA 40-pin drives. All other features are the same as the 15-bay FORTRA
Tower.
2/4/6/8/10/12/15-bay Product Family Features
FORTRAand
SSttoorrBBllaaddee
are families of high-end enclosures designed for
high-volume performance storage solutions. The following table shows the features of the FORTRA
2/4/6/8/10/12/15-bay and
SSttoorrBBllaaddee
products:
1-1
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
1. Introduction
2-bay
4-bay
1,3
6-bay
*1,3
8-bay110-bay
*1,2
12-bay
15-bay
*1,3
StorBlade
Number of Device Bays 2 4 6 8 10 12 15 4 Number of Blowers 1 1 1 or 2 2 2 2 2 2 Number of Power Supplies 1 1 1 or 2 2 2 2 2 1 or 2 Number of I/O Channels (SCSI Only) 1 1 2 2 2 2 2 SCSI SE/LVD Supported
2 2 2 2 2 2 2
Fibre Channel Supported
2 2 2 2 2 2
Hot-Swap Canisters
2 2 2 2 2 2 2 2
Removable Power Supplies
2 2 2 2 2 2 2
Fibre only
Removable Blowers
2 2 2 2 2 2 2
Fibre only
N+1 Power Supplies
2 2 2 2 2
Fibre only
N+1 Blowers
2 2 2 2 2 2
MIA Support (FC Only)
2 2 2 2
Loop Expansion Support (FC Only)
2 2 2 2
2
2 2
Daisy Chainable (SCSI Only)
2 2 2 2 2
2
2
Built-in Termination (SCSI Only)
2 2 2 2
Auto Termination (SCSI Only)
2 2 2 2
SAF-TE/SES Ready (Optional)
2 2 2 2
Fibre only
SAF-TE/SES Compatible
2 2 2 2
Fibre only
SCSI to SCSI RAID Support
2 2 2 2
Fibre to SCSI RAID Support
2 2
Fibre to Fibre RAID Support
2 2 2
Fibre to ATA RAID Support
2
SCSI to ATA RAID Support
2
(D)esktop/(T)ower/(R)ackmount D D DTR T TR R TR R
* 6/10/15-bay unit features apply to both Tower and Rackmount models 1 Features are based on a standard configuration with no internal host controller(s) installed 2 Fibre channel 10/15-bay enclosures have built-in SES 3 Fibre Channel 2Gb Model available. 2Gb models use SFP transceivers.
1-2
FORTRA15-bay I4 Infortrend 5251F44 Installation Guide Rev A
FORTRAproducts use advanced mid-plane technology developed by JMR,
which allows power supplies, drives, and all other enclosure components to interface into a single board. This provides superior performance and easy connectivity.
The host interface supports SFP Fibre Channel connections at 2Gb/s.
All 15-bay FORTRA
2Gb/s Fibre enclosures have built-in SES on the personality card that allows control and monitoring of some enclosure components.

Rackmount Specifications

Dimensions/Weight
Unit Weight 40 lbs. (18.2kg) Height 5-1/4" (3U) (133mm) Width 19" (483mm) Depth 23" (584mm)
Power Supply (Each power supply includes internal cooling fan) Quantity: 2 Power: 430 Watts each (N+1) Power Factor Correction Input: 100-260 VAC; 50-60Hz Output: +5V @ 35A
+12V @ 30A
Blower
Quantity: 4 (2 per cannister) Size: 97mm (3.82") each Air Flow: 25.42CFM (0.72m3/min) each Noise: 52dB(A)

Tower Specifications

Dimensions/Weight
Unit Weight 43 lbs. (19.5kg) Height 20-1/2" (521mm) Width 9-5/8" (235mm) Depth 24" (610mm)
Power Supply (Each power supply includes internal cooling fan) Quantity: 2 Power: 430 Watts each (N+1) Power Factor Correction Input: 100-260 VAC; 50-60Hz Output: +5V @ 35A
+12V @ 30A
1-3
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
Blower
Quantity: 4 (2 per cannister) Size: 97mm (3.82") each Air Flow: 25.42CFM (0.72m3/min) each Noise: 52dB(A)
Fibre Channel Features

Loop Expansion

FORTRA15-bay 2Gb/s Fibre Channel JBOD enclosures include a loop
expansion I/O connector on each fibre channel drive port. This allows the connection to other Fibre Channel JBOD enclosures.
Loop Bypass and Clock Timing Circuit
Each port includes a loop bypass circuit that monitors each slot for a loop connection. It has two modes of operation: NORMAL and BYPASS. In NORMAL mode, the device is connected to the loop. In BYPASS mode, the device is either absent or non-functional and data bypasses to the next available device until the correct device is located.
The unit also has a built-in clock recovery circuit that adjusts the timing for any input or output that is going through the enclosure.
SFP Connector
The 15-bay 2Gb/s Fibre Channel enclosures use Small Formfactor Plug (SFP) as the Fibre I/O ports.
Dual Loops
A single loop is required for unit operation, however both loops can be used to connect to different hosts, dual host adapters, and other devices, for flexible and even redundant configurations. For specific connection and installation information, refer to Chapter 4
.

ID Selection

0-124 device ID addresses are addressable and can be easily set-up via ID rotary switches located on the personality modules. For specific connection and installation information, refer to Chapter 4
.
SES
The 15-bay Fibre Channel enclosures have a built-in SES processor on the personality card. See Chapter 8
for SES information.
2-1
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
This chapter covers specification information for all FORTRAenclosures. The following matrix describes the available configurations for FORTRA
and
SSttoorrBBllaaddee
TTMM
enclosures.
2. Hardware Specification
FR XX X L 2
1 X 2
X XX X X
SINGLE/DUAL CONTROLLER
S = Single Controller D = Dual Controller
BACKPLANE TYPE
- = 1 Gigabit Backplane 2 = 2 Gigabit Backplane
CONTROLLER MANUFACTURER/MODEL#/INTERFACE
- = None (Blank if at the end of P/N) H1 = Chaparral G5312/ LVD Host/ LVD Drives H2 = Chaparral G7313/ 1G Fibre Host/ LVD Drives H3 = Chaparral K5312/ LVD Host/ LVD Drives H4 = Chaparral K7313/ 1G Fibre Host/ LVD Drives H5 = Chaparral JSS122/ LVD Host/ LVD Drives H6 = Chaparral JFS124/ 1G Fibre Host/ LVD Drives H8 = Chaparral JFS224/ 2G Fibre Host/ LVD Drives FZ = Microtest FileZerver Network Attached/Ethernet/ LVD Drives ES = Infortrend 7250F-U3 SCSI Host/ ATA Drives w/ethernet EF = Infortrend 7250F-F2 Fibre Host/ ATA Drives w/ethernet I 2 = Infortrend Sentinel 3250-50/ LVD Host/ LVD Drives
Infortrend Sentinel 3250-50 w/IFT9282F/ 1G Fibre Host/ LVD Drives I 3 = Infortrend EonRAID 5200-50 w/IFT9288B6B/ 1G Fibre Host/ 1G Fibre Drives I 4 = Infortrend EonRAID 5251F4/ 2G Fibre Host/ 2G Fibre Drives I 5 = Infortrend SentinelRAID 3252/ LVD Host/ LVD Drives I 6 = Infortrend EonRAID 5251F6/ 2G Fibre Host/ 2G Fibre Drives I S = JMR 7250-U3/ SCSI Host/ ATA Drives I F = JMR 7250-F2/ 2G Fibre Host/ ATA Drives M 3= Mylex DAC-FFx/ 1G Fibre Host/1G Fibre Drives M 5= Mylex DAC-FFx2+Ethernet/ 2G Fibre Host/ 2G Fibre Drives w/ethernet
SAF-TE/SES
- = None (Blank if at the end of P/N) S = SAF-TE/SES
POWER SUPPLY QUANTITY
# = A number Equal to Power Supplies in Enclosure
AC or DC POWER SUPPLY
- = AC Power Supply
D = DC Power Supply
COLOR - CANISTER/ACCENT
1 = Silver/Opal 2 = Black/Black 3 = Silver/Black 4 = Blue/Blue
DRIVE I/O SCSI CHANNELS or FIBRE LOOPS
# = A Number Equal to Drive I/O Channels
ENCLOSURE I/O
L = SCSI 3 Ultra 160 (LVD/SE Multimode, Fast-Wide, HD68) F = 1 or 2Gb/s Fibre Channel A = ATA
FIBRE GBIC READY
- = No GBIC Slots
G = GBIC Ready
NUMBER OF DRIVES
# = Drives (02,04,06,08,10,12,15)
FAMILY SERIES
FR = Fortra Rackmount FT = Fortra Tower 1U = StorBlade Rackmount
u.s. Power cords Included For International Models
Add Power Cord: Australia = CBL-00602 Europe = CBL- 00525 UK = CBL-00677
2-2
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A

Environmental Specifications

Operating Temperature: 5°C to 40°C (41°F to 104°F) Storage Temperature: 0°C to 65°C (32°F to 149°F)
The maximum recommended ambient temperature depends on the recommendation of the manufacturer for the devices being installed.

Electrical Specifications

AC Inlet Type: IEC320/EN60320 Power Cord: NEMA5-15P Power Supply: Auto-switching for 110/220V operation

Agency Compliance

FORTRAenclosures have been designed and built to comply with the FCC,
UL, CSA/TUV, CE, and C-Tick standards. For more information on FCC Class A compliance, see page 2.
Packaging Specifications
FORTRApackaging has been designed to be reusable and recyclable. Drives
may be installed and shipped in the canisters as long as the canisters are not installed in the enclosure. Shipping the unit with canisters and/or power supplies installed in the enclosure may cause damage to the enclosure or to the drives and will void the warranty.
Packaging complies with ISTA (International Safe Transit Association) standards and has been ISTA certified.
Each canister is pre-packaged in an anti-static bag. Do not throw the packaging away if the product is intended for re-shipping. When transporting or shipping a JMR approved shipping container must be used.

Disclaimer

The original product packaging has been tested and is safe under normal shipping circumstances. Reshipping the product without using the original product packaging will void the warranty. Do not ship the unit with canisters and/or power supplies installed in the enclosure as this will void the warranty and could cause damage to the unit and drives. The canisters should be packaged separately within the product packaging, as provided.
SAFETY TIP: Reshipping the enclosure with canisters, drives, or power
supplies installed in the enclosure may cause damage to these components and will void the warranty
SICHERHEITSHINWEIS: Der Versand des Gehäuses mit eingebauten
Einschüben, Platten und Netzteilen kann zur Beschädigung dieser Komponenten führen und somit den Garantieanspruch gefährden.
Loading...
+ 21 hidden pages