Making Sense Out of Motion…
LSM Series Accelerometers
have 100,000 hour MTBF
reliability and up to 20g full
scale sensing range
If space is a concern, the Jewell
is the solution for you. The LSM
offers equivalent features to the LSA
Outline Drawing: Dimensional Drawing for the LSM Accelerometer (inch/mm)
in a smaller package - approximately
1" cub. Its wide input range and
bandwidth features meet the
demanding needs of a variety of
aerospace applications.
Features & Benefits
• ±0.5g to ±20.0g Full Range
• Filtering up to 200 Hz Bandwidth
• Satellite Application Reliability
• Better than 20 µg Res at 10g Full Scale
• -55°C to +95°C Operating Temp Range
Block Diagram: LSM Accelerometer
• Satellite Nutation Sensing
• Train Braking and Banking
• Train Performance Testing
• Wind Shear Detection Systems
• Thermal Vacuum Chamber (product) Testing
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
Making Sense Out of Motion…
LSM Accelerometer Specifications
PERFORMANCE
Input Range, g (Note 1) ± 0.5 ± 1.0 ± 2.0 ± 5.0 ± 10.0 ± 20.0
Full Range Output (FRO V± 1.0%)
± 5.0 ± 5.0 ± 5.0 ± 5.0 ± 5.0 ± 5.0
Non Linearity (%FRO, Max.) (Note 2)
0.05 0.05 0.05 0.10 0.10 0.25
Scale Factor (V/g, Nom.) 10.0 5.0 2.5 1.0 0.5 0.25
Scale Factor Temp Sens (PPM/°C, Max.) 200 200 200 200 200 200
Bias, g, (Max.) 0.050 0.010 0.010 0.010 0.020 0.050
Bias Temp. Sens., (µg/°C)
50 50 50 100 100 200
Natural Frequency, Hz, (Nom.) (Note 3) 70 100 140 100 140 160
Bandwidth (-3db), Hz, (Nom.) 70 100 140 100 140 160
Input-Axis Misalignment, °(Max.)
± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0
Resolution and Threshold, µg 10 10 10 10 20 50
ELECTRICAL
Input Voltage (Vdc Nom.) (Note 4)
Input Current (mA, Nom.)
Output Impedance (Ohms, Nom.) 10k 5k 2.5k 5k 2.5k
Noise, mV rms (Max.)
ENVIRONMENTAL
Survival Temp Range
Shock
Seal
Weight
Notes: 1 - Full range is defined as "from negative full input acceleration to positive full input acceleration."
2 - Nonlinearity is specified as deviation of output referenced to a best fit straight line,
independent of misalignment.
3 - Output phase angle = -90°
4-Unit Power connections can be easily adapted for operations from single-ended, floating power
supplies of 24 to 36 Volts DC.
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955