Jewell Instruments Lily Specifications

LILY Self-Leveling Borehole Tiltmeter
The LILY Self-Leveling Borehole Tiltmeter is a precision, dual axis sensor package designed for specialized applications and research. Applications include volcanic and tectonic research, hydraulic fracture mapping, micro-deformation monitoring, deep ocean geophysics, and more.
Using a high-precision electrolytic tilt sensor, units deliver resolution to 5 nanoradians; dynamic range is ±330 μradians. Units also feature a +/-10 deg. leveling range for easy installation downhole. Output is RS232 or RS422 (RS485 full duplex) and includes timestamp and compass bearing. Data can be saved to file externally or to LILY’s on-board flash memory (75,000 sample max) using fill/stop or cyclic memory modes.
Units are fully submersible to 3000 psi. Titanium is also available for +5000 psi applications. The culmination of over 30 years of tilt sensor experience and expertise, the LILY represents the pinnacle in precision sensor engineering. Contact Jewell Instruments today for more information about this powerful instrument.
Specifications Channels X tilt, Y tilt, azimuth, temperature
Resolution < 5 nanoradians
Repeatability
Dynamic Range
Self-Leveling Range ±10 degrees
Non-Linearity
Frequency Resonse < 1 Hz
Ks Temp Coefficient (%/°C) ±0.02%/°C
Kz Temp Coefficient (bias/°C)
Azimuth detection On-board magnetic compass, 0° to 360° output
Output RS232 and RS422 standard (user selectable)
Baud rate 9600, 19200 (default), 28800, 57600, 115200, 230400
Sample rate User programmable from 10 samples/sec to 1 sample/day
Output Format NMEA XDR, Trimble TCM, Ashtech, Simple (Timestamp, X, Y, Temp, Compass, S/N)
On-board Memory 2 Megabytes nonvolatile Flash memory (64,000 samples)
Real-time Clock Accurate to 10 minutes/year or better
Power 7 to 28 VDC @ 30 mA (< 10 mA sleep); 250 mV ripple max., reverse polarity protected
Environmental -25°C to +85°C operational, -30°C to +100°C storage. 3000 psi
Dimensions 51mm O.D. x 915mm (2 x 36 in); handle length 150mm (6 inches); 4.5 kg (10 lb)
Materials 304 stainless steel, nonmagnetic (6Al-4V Titanium available on request: to +5000 psi)
Same as resolution under static conditions
±330 µradians
0.2% of full span
±3 µradian/°C
Specifications subject to change without notice as the result of ongoing development
Jewell Instruments LLC 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
L00259 Rev. B