Jewell Instruments LCF-3500 Specifications

LCF-3500 Series Accelerometer
Making Sense out of Motion…
Input From ±0.5g to ±5.0 g
Full Range. Exceptional Bias and Scale Factor. Specifically Designed for High Shock and Vibration Environments.
Suspension Fluid Damped Tri-Axial Outline Diagram
Accelerometer is a ±0.5G to ±5G device
designed for applications where high
levels of shock and vibration are present.
LCF units are characterized by excellent
turn on repeatability and very low
hysteresis.
Features & Benefits
±0.5g to ± 5.0g Full Range
Filtering 5 to 100 Hz Bandwidth
Exceptional Bias & Scale Factor
High Level ± Vdc Output
1,500g Shock Capability
Tri-Axis
Applications Pin Out
Geophysical Testing
Railcar Acceleration Control
Railcar Deceleration Control
Ocean Buoy Acel Sensing
Aircraft Stability Control
Aircraft Flight Testing
Vehicle Roadway Profiling
Tri-Axis Acceleration Applications
sales@jewellinstruments.com www.jewellinstruments.com Tel (800) 227-5955
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
LCF-3000 SeriesAccelerometer
Making Sense out of Motion…
Performance Specifications
STATIC/DYNAMIC
Input Range (g) (Note 1) ± 0.50 ± 2.0 ± 5.0
Full Range Output (FRO), volts ± 0.5% ± 5.0 ± 5.0 ± 5.0
Non Linearity (%FRO, Max.) (Note 2)
0.05% 0.05% 0.05%
Scale Factor, volts/g (Nominal) 10.0 2.50 1.00
Scale Factor Temp. Sens., (PPM/°C, Max.) 100 100 100
Bias, g (Max.) 0.005 0.005 0.005
Bias Temp. Sens., micro g/° (Max.)
100 100 100
Natural Frequency, Hz min (Note 3) 30 30 30
Bandwidth (-3dB), Hz min 30 30 30
Input Axis Misalignment, ° (Max.)
1.0 1.0 1.0
Resolution and Threshold, micro g (Max.) 10 10 10
ELECTRICAL
Input Voltage, VDC
Input Current (mA, Nominal):
Output Impendance, ohms (Nominal)
Noise, Vrms (Max.)
ENVIRONMENTAL
Operating Temp Range
Survival Temp Range
Vibration
Shock Seal
Notes: 1 - Full range is defined as "from negative full input acceleration."
2 - Referenced to best-fit straight line independent of misalignment.
3 - Output phase angle = -90°.
Custom Capabilities
Unit Power Connections can be easily adapted for operations from single-ended, floating power
supplies of 24 to 36 Volts DC
Internal Temperature Sensor
4-20 mA output
How to Order
LCF-3500-.5g/.5g/.5g Call for part number
LCF-3500-2.0g/2.0g/2.0g Call for part number
LCF-3500-5.0g/5.0g/5.0g Call for part number
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com www.jewellinstruments.com Tel (800) 227-5955
±12 to ±18
±15
100
0.002
-40 to +80°C
-60 to +90°C
20 grms
1000g, 1 msec, ½ sine
Epoxy
Loading...