Jewell Instruments LCF-2330 Specifications

LCF-2330 Series Dual Axis Inclinometer
Making Sense Out of Motion…
The Jewell LCF-2330 Series
Inclinometer is a dual axis version of the rugged and high accuracy LCF Series.
was optimized to provide the high accuracy and superior repeatability
Dimensional Drawing: LCF-2330 Inclinometer Series
of Jewell's rugged, fluid damped, flexure suspension, servo technology in a small and convenient package for applications requiring a compact dual axis solution.
Features & Benefits
±1° to ±90° Input Full Range
Micro Radian Resolution
Available Internal Temp Sensor
High Level ± 5 Vdc Output
Superior 0° Output Stability over
Temperature
Low Impedance Output
Applications
Pin-Out: LCF-2330 Inclinometer Series
Radar & Antenna Leveling
Weapons Platform Leveling
Barge and Offshore Platform Control
Deviation Surveys
2-Axis Machine Tool Leveling
Bridge Structural Monitoring
Submersible Control Feedback
Offshore Platform Stability
Production/Manufacturing Process
Equipment for Aerospace Industry
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com www.jewellinstruments.com Tel (800) 227-5955
LCF-2330 Series Dual Axis Inclinometer
Making Sense Out of Motion…
LCF-2330 Inclinometer Specifications
PERFORMANCE
Input Range (°) ± 1.0 ± 3.0 ± 14.5 ± 30.0 ± 90.0
Full Range Output (FRO), Volts, ±1% (Note 1)
± 5.0 ± 5.0 ± 5.0 ± 5.0 ± 5.0
Non Linearity (%FRO, Max.) (Note 2)
0.05 0.05 0.02 0.02 0.02
Scale Factor (V/g, Nom.) 286.5 95.5 20.0 10.0 5.0
Scale Factor Temp Sens (PPM/°C, Max.) 300 300 100 60 60
Bandwidth (-3dB), Hz, Nom. 2.0 3.0 30.0 30.0 30.0
Transverse Axis Misalignment, (°, Max.)
±0.25 ±0.50 ±0.50 ±1.00 ±1.00
Output at 0° Tilt, Volts, Max. 0.10 0.04 0.02 0.02 0.02
0° Output Temp Sens, Volts/°C, Max. 0.015 0.005 0.001 0.0005 0.0003
Resolution and Threshold
1µradian
ELECTRICAL
Input Voltage (Vdc) ±12 to ±18
Input Current (mA, Nom.) 30
Output Impedance (Ohms, Nom.) 100
Noise (Vrms, Max.) 0.002
ENVIRONMENTAL
Operating Temp Range
Survival Temp Range
Vibration
Shock
Seal
Weight 8.0 oz.
Notes: 1 - Full range is defined as "from negative full input angle to positive full input angle."
2 - Nonlinearity is specified as deviation of output referenced to theoretical sine function value,
independent of misalignment.
How to Order
LCF-2330- 1/1 468233-005
LCF-2330- 3/3 468233-006
LCF-2330- 14.5/14.5 468233-002
LCF-2330- 30/30 468233-003
LCF-2330- 90/90 468233-004
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com www.jewellinstruments.com Tel (800) 227-5955
-40°C to +80°C
-60°C to +90°C
20 grms
1000g, 1 msec, 1/2 sine
MIL-STD 202, Method 112