![](/html/f4/f405/f405b930c6120c27efd21622c5ee9d757706e1b3f7f56a35d65da6273e862cba/bg1.png)
JDI-100/200 MEMS Inclinometer Series
RS485, Digital Output
Making Sense out of Motion…
• ±1°, ±3°, ±14.5°, ±30° and ±60° ranges
• Robust and Rugged Enclosure
• Single and Dual Axis Models Available
• Low-Cost MEMS Technology
• Single DC Power Input, Galvanically Isolated
• RS-485 Half Duplex, Galvanically Isolated
• Integrated Temperature Sensor
• IP67 Seal (when mated to IP67 connector)
• Industrial Automation & Control Pin Out
• Construction & Agricultural Equipment
• Platform Leveling/Positioning
Jewell has a 40+ year history of providing
precision force
-balanced inclinometers and is
pleased to provide MEMS parts with the same
attention to detail that our customers demand.
The
JDI-100/200 series is a digitally temperature
compensated inclinometer available in single (JDI-100)
and dual (JDI
-200) axis configurations. This presents a
robust and rugged design for industrial use, but with
the benefit of low
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
![](/html/f4/f405/f405b930c6120c27efd21622c5ee9d757706e1b3f7f56a35d65da6273e862cba/bg2.png)
JDI-100/200 MEMS Inclinometer Series
RS485, Digital Output
Making Sense out of Motion…
Performance Specifications
PERFORMANCE STATIC/DYNAMIC
Measurement Range¹ (°)
±1 ±3 ±14.5 ±30 ±60
Absolute Accuracy2 (°, typ)
0.015 0.015 0.015 0.015 0.015
Relative Accuracy2 (°, typ)
0.004 0.004 0.004 0.004 0.004
Digital Resolution (°, max)
0.0001 0.0001 0.0001 0.0001 0.0001
Repeatability (°)
0.01 0.01 0.01 0.01 0.01
Bias Over Temperature (ppm / °C) 80 80 80 80 80
Transverse Axis Misalignment (°, max) 0.25 0.25 0.25 0.25 0.25
Bandwidth (Hz nom) (-3 dB)
Non-Linearity (% FS) 0.60 0.20 0.05 0.03 0.02
Accuracy - Temperature Sensor (°C, max) ±1 ±1 ±1 ±1 ±1
Warm Up Time (seconds max) 0.5 0.5 0.5 0.5 0.5
Number of Axes 1 or 2
Input Voltage Range (VDC) 5 min, 9 to 36 typ, 38 max, reverse wiring protected
Power - RS485 termination enabled (mW, max) 800.0
Power - RS485 termination disabled (mW, max) 600.0
Galvanic Isolation - Power Inputs (VAC) 2000
Galvanic Isolation - RS485 (VAC) 5000
Protocol Half Duplex, Proprietary ASCII, CRC is optional
Baud 3 (bps) 300 (min), 9600, 19200, 38400, 57600, 115200, 250000, 500000 (max)
Communication Settings
3
8 bits, 1 stop bit, even|odd
Data Sample Rate 3 (Hz) 3.9, 7.8, 15.6, 31.2, 62.5, 125
Node ID
3
Enter "0" followed by the last two digits of specific sensor’s serial number
Filtering User selectable
Bus Termination - internal 3 (120Ω) On / Off
ENVIRONMENTAL / MECHANICAL
Operating Temp. Range
Storage Temp. Range
Shock
Vibration
Weight (oz , [grams])
Seal
Notes: 1 - Custom ranges available on request. 2 - Observed using noise reduction methods. 3 - User Selectable, default is underlined.
Jewell Instruments LLC, 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955