Jewell Instruments A900 Specifications

Model 900 Biaxial Clinometer
±
±
±
1
2
3
±
*
Specifications subject to change without notice on account of continued development
; 1Resolution
calculated a
t 1mV; 2Linear scale factor
The model 900 Biaxial Clinometer is an inexpensive, gravity-referenced clinometer (tiltmeter) with a wide dynamic range. Its small size and high precision make it a versatile choice for many measurement and control applications. Units are available with +/-2.5V or 0-5V DC output. Custom calibration ranges are also available on request. Units ship standard with 18” hook-up cable. Use the model 900 for industrial pitch and roll measurements, platform position and control, OEM assemblies, specialized research applications, and more.
High-Gain Standard Wide-Angle Angular Range Resolution Repeatability Scale Factor Non-Linearity Output Channels X-tilt, Y-tilt, Temperature Kz Coefficient (deg/C) Ks Coefficient (%/C) Time Constant 0.15 sec Natural Frequency 10 Hz Output Impedance 270 ohms, short circuit protected Power +8 to +24 VDC (bipolar output); +10.5 to +26.5 VDC (0-5V output); 7mA,
Environmental -40 to +85 C operating and storage. 0-90% humidity Dimensions 2 x 2 x 0.64 inches (51 x 51 x 17 mm), 0.5 oz. (15g) Materials Glass electrolytic sensor, fiberglass PCB
10°
0.005° 0.01° 0.02°
0.02° 0.02° 0.02° 4°/V 10°/V 25°/V
1% 2.5% 7%
25°
2.5 VDC or 0-5 VDC
10-20 arcsec/C (typical)
0.03%/C (typical)
250 mV ripple max, reverse polarity protected
50°
calculated from BFSL through calibration curve; 3Linearity calculated as max % deviation from BFSL. 0.05% linearity achievable using a polynomial
Ordering Code: Pin-out/Wiring:
Jewell Instruments LLC 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
Pin Color Function
1 Red V+
2 Black GND
3 Blue X-Out
4 Green Y-Out
5 Yellow Temp Out
L00021 Rev. A
Model 900 Biaxial Clinometer
Outline Diagram:
1
Resolution calculated a 1mV 2Linear scale factor calculated from BFSL3Linearity calculated as max % deviation
from BFSL. 0.05% linearity achievable using a polynomial
Jewell Instruments LLC 850 Perimeter Road, Manchester, NH 03103
sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227-5955
L00021 Rev. A