Jet H3650, H3432 Operator's Manual

OPERATOR'S MANUAL
DIGITAL BATTERY LOAD TESTER - PROD. NO. H3650 BATTERY LOAD TESTER - PROD. NO. H3432
H3650 H3432
WARNING - RISK OF EXPLOSIVE GASES
• Working in the vicinity of a lead acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it is of utmost importance that each time before using your tester, you read these instructions carefully and follow instructions by battery maker as well.
risk of battery explosion, follow these instructions and those published by
www.jetequipment.com
1
H3650 DIGITAL BATTERY LOAD TESTER
BATTERY ANALYSIS - Click “ENTER” & wait for 10 seconds of load. Load test results will be:
LOAD TEST BATTERY CONDITION
OK (GREEN LED LIGHT) Battery capacity is good.
OK BUT WEAK (GREEN+YELLOW LED LIGHT)
WEAK (YELLOW LED LIGHT) Battery capacity is unsatisfactory. Battery may be either: (1)
BAD (RED LED LIGHT) Battery may be defective (e.g. a bad cell).
NOTE: If battery volts is under 12.3V, tester will not allow and should not load test, “c.b” (Charge battery) will be shown on LED display. Please fully charge battery before test.
termine state of charge by checking specific gravity (use hy­drometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to full charge.
Review the comparison chart cover to see if this battery is ”OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.
defective or (2) partly discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered de­fective. If gravity is cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to full charge level, the battery is either sulfated or has lost active material.
May or may not be fully charged. De-
of load test result on the meter
under 1.225, recharge battery and re-test. If
2
1
www.jetequipment.com
Loading...