Dimensions (Actual Size)

 

 

Cutout width:

28

3/16"

 

Cutout height:

27

7/16"

 

Minimum cabinet width:

30"

 

Minimum cabinet depth:

23

1/2"

Recommended cutout location from floor : 4" to 33"

Distance from face of cabinet to

outer edge of open door (Door swing): 20 1/2"

Distance from face of cabinet to

front of closed door handle: 2 5/8"

Overall unit width: 29 3/4"

Overall unit height: 29"

Penetration into cabinet: 23 1/2"

Oven overlap distances when using cutout dimensions listed above:

Top overlap: 1 5/16"

Bottom overlap: 0"

Right side overlap: 3/4"

Left side overlap: 3/4"

Additional Information

Total connected load: 3.6KW, 15 amps @120/240v. 3 wire single phase, 60Hz.

•A complete floor is recommended to prevent unusual drafts and capable of supporting 142 lbs.

Minimum distance from bottom of opening to any object protruding from cabinet face (i.e. cabinet door) directly below: 7/8" (because it is an air flow area)

SEE PAGE 2 FOR UNDERCOUNTER INSTALLATION

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2002.

214

Cabinet Opening

(not to scale)

Locate electrical box in this location. Provide a 1 1/4" conduit hole in the rear right hand side of the opening floor.

30"

 

28 3/16"

 

 

 

 

 

 

 

 

 

23 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 7/16"

4" to 33"

Overall Dimensions

(not to scale)

29"

23 1/2"

29 3/4"

2 5/8"

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN205.05 • A214B149 • • 032603 • 95654 • 23941

associated with reusing old Data Sheets.

www.dexpress.com

 

 

 

 

This Data Sheet Includes Information On

 

 

 

 

DIMENSION EXPRESS

 

 

 

 

Jenn-Air

 

 

 

 

Page 2

 

 

Product Model Number (s):

 

 

 

 

 

 

 

 

Fax on Demand (775) 833-3600

 

 

 

30" Undercounter or Wall Ovens:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W30400P, W30400PF, W30400PG, W30400PK,

 

 

 

 

 

 

 

 

 

W30400PR and W30400PU

 

 

 

 

Additional Information:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you are stacking two units: Maximum distance from floor to bottom of lower oven opening is 7 1/2". Minimum distance from top of lower oven opening to bottom of upper oven opening is 1".

House wire to enter junction box at left side. Range wires to enter right side of junction box.

Can be installed under Jenn-Air models CCE1400, CCE3400, CCE3530, CCG2420 an CCG2421 cooktops..

See below for undercounter installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabinet (under counter) Opening

 

 

 

25" normal counter top depth

 

 

 

 

 

 

 

 

 

CL

 

 

 

 

 

 

 

 

 

(not to scale)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooktops listed above

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

may be installed over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

oven. See cooktop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation instructions for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cooktop cutout size. The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/2" countertop

oven cutout should be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 7/16"

 

 

 

23 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

located so that the oven

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/4" Dia conduit access hole as close

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

will not interfere with the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cooktop tub.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to the rear right corner as possible or in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjacent right side compartment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/8" plywood bottom must

 

 

 

 

 

 

 

 

 

 

 

 

28 3/16"

 

 

 

 

 

 

 

 

 

 

 

support 142 pounds

 

 

36" standard countertop height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24"

 

 

 

 

 

 

 

1 1/2" countertop thickness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recommended cutout:

 

 

 

 

 

 

 

36" countertop height reccomended

 

 

 

 

 

 

 

28 3/16" wide by 27 7/16" high

 

 

 

 

 

 

 

 

 

 

 

 

Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.

Copyright © Dimension Express, 2002.

149

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633 •

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN205.05 • A214B149 • • 032603 • 95654 • 23941

associated with reusing old Data Sheets.

Loading...