Jenn-Air W30400P, W30400PF, W30400PG, W30400PK, W30400PR Dimension Guide

...
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
W30400P, W30400PF, W30400PG, W30400PK,
W30400PR and W30400PU
• Dimensions (Actual Size) •
Cutout width:
Cutout height:
Minimum cabinet width:
Minimum cabinet depth:
Recommended cutout location from floor :
28 3/16" 27 7/16" 30" 23 1/2" 4" to 33"
Distance from face of cabinet to
20 1/2"
Distance from face of cabinet to
front of closed door handle:
Overall unit width:
Overall unit height:
Penetration into cabinet:
2 5/8" 29 3/4" 29" 23 1/2"
Oven overlap distances when using
cutout dimensions listed above:
Top overlap:
Bottom overlap:
Right side overlap:
1 5/16" 0" 3/4"
Left side overlap: 3/4"
• Additional Information •
• Total connected load: 3.6KW, 15 amps @120/240v. 3
wire single phase, 60Hz.
•A complete floor is recommended to prevent unusual
drafts and capable of supporting 142 lbs.
• Minimum distance from bottom of opening to any
object protruding from cabinet face (i.e. cabinet door) directly below: 7/8" (because it is an air flow area)
Cabinet Opening
(not to scale)
Locate electrical box in this location. Provide a 1 1/4" conduit hole in the rear right hand side of the opening floor.
30"
28 3/16"
23 1/2"
27 7/16"
4" to 33"
Overall Dimensions
(not to scale)
SEE PAGE 2 FOR UNDERCOUNTER INSTALLATION
29"
23 1/2"
29 3/4"
2 5/8"
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
214
BN205.05 • A214B149 • • 032603 • 95654 • 23941
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• If you are stacking two units: Maximum distance from floor to bottom
of lower oven opening is 7 1/2". Minimum distance from top of lower oven opening to bottom of upper oven opening is 1".
• House wire to enter junction box at left side. Range wires to enter
right side of junction box.
• Can be installed under Jenn-Air models CCE1400, CCE3400,
CCE3530, CCG2420 an CCG2421 cooktops..
• See below for undercounter installation.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
W30400P, W30400PF, W30400PG, W30400PK,
W30400PR and W30400PU
25" normal counter top depth
Cooktops listed above may be installed over oven. See cooktop installation instructions for cooktop cutout size. The oven cutout should be located so that the oven will not interfere with the cooktop tub.
36" standard countertop height 1 1/2" countertop thickness
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
27 7/16"
28 3/16" wide by 27 7/16" high
23 1/2"
28 3/16"
Recommended cutout:
C
L
Cabinet (under counter) Opening
5/8" plywood bottom must support 142 pounds
24"
BN205.05 • A214B149 • • 032603 • 95654 • 23941
(not to scale)
1 1/2" countertop
1 1/4" Dia conduit access hole as close to the rear right corner as possible or in adjacent right side compartment.
36" countertop height reccomended
149