www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
W132B and W132W
33"
30 1/8"
24"
• Dimensions (Actual Size) •
Minimum cabinet width:
Cutout width:
Cutout height:
Recommended cutout location from floor :
Minimum inside cabinet depth:
33"
30 1/8"
28 1/8"
34"
24"
Distance from face of cabinet to
outer edge of open door(s):
20 1/2"
Distance from face of cabinet to
front of closed door handle:
Overall unit width:
Overall unit height:
Penetration into cabinet:
4 3/4"
30 1/2"
28"
24"
Distance from opening floor
to centerline of electrical:
24 11/16"
Distance (left) from opening centerline
to centerline of electrical:
2 1/4"
Oven overlap distances when using
cutout dimensions listed above:
Top overlap:
Bottom overlap:
Right side overlap:
see below
0"
3/16"
Left side overlap: 3/16"
• Additional Information •
• The unit does NOT overlap the top of the opening.
There is a trim piece that covers the top edge of the
cutout a very small amount (less than 1/16").
• Maximum cutout width: 30 1/4"
• IMPORTANT: nylon grip nuts that hold crate bottom
must be removed before installation.
• Total connected load: 5.9KW, 24.6 amps @120/240v
or 4.4KW, 21.2 amps @120/208v. 3 wire single phase,
60Hz.
•A complete floor is recommended to prevent unusual
drafts and capable of supporting 160 lbs.
• Minimum distance from bottom of opening to any
object protruding from cabinet face (i.e. cabinet door)
directly below: 1" (because it is an air flow area)
Cabinet Opening
(not to scale)
2 1/4"
C
L
24 11/16"
Provide for 120/240,
120/208-volt electrical
connection in this area.
28 1/8"
34"
Overall Dimensions
(not to scale)
28"
SEE PAGE 2 FOR UNDERCOUNTER INSTALLATION
24"
30 1/2"
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
203
4 3/4"
BN205 • A203B149 • 31469 • 000107 • 123829 • 47315
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• If you are stacking two units: Maximum distance from floor to bottom
of lower oven opening is 7 1/2". Minimum distance from top of lower
oven opening to bottom of upper oven opening is 3/4".
• House wire to enter junction box at left side. Range wires to enter
right side of junction box.
• IMPORTANT : CANADA INSTALLATIONS ONLY - Breaker box
provided with oven must be located in an adjacent accessible location
on either side of oven (undercounter) or below (wall mount).
• W132W : White with touch control.
• W132B : Black with touch control.
• See below for undercounter installation.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Undercounter or Wall Ovens:
W132B and W132W
• Minimum distance from the top of the counter top to the bottom of
the oven opening when installing a Jenn-Air Gas cooktop above:
32". Recommended oven opening cutout: 30 1/8" wide by 28 1/8"
high. Gas and electrical connections for the cooktop must be located
in an adjacent accessible location. For cooktop dimensions please
request the proper data sheet.
• Minimum distance from the top of the counter top to the bottom of
the oven opening when installing a Jenn-Air electric cooktop above:
29 11/16". Recommended oven opening cutout: 30 1/8" wide by 28
1/8" high. Electrical connections for the cooktop must be located in
an adjacent accessible location. For cooktop dimensions please
request the proper data sheet.
• When installing 2 units side-by-side, the openings must be
separated a minimum of 6". Each unit must have its own electrical
box located on the wall of the opening.
25" normal counter top depth
Minimum distance from the
top of the counter top when
installing a Jenn-Air Gas
cooktop above: 32". Gas
and electrical connections for
the cooktop must be located
in an adjacent accessible
location. For cooktop
dimensions please request
the proper data sheet.
Minimum distance from the top of
the counter top when installing a
Jenn-Air electric cooktop above:
29 11/16". For cooktop
dimensions please request the
proper data sheet.
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
28 1/8"
30 1/8" minimum
30 1/4" maximum
Recommended cutout:
30 1/8" wide by 28 1/8" high
2 1/4"
C
L
120/240v, 120/208v electrical connection in this area
Cabinet (under counter) Opening
24"
36" countertop height reccomended
BN205 • A203B149 • 31469 • 000107 • 123829 • 47315
(not to scale)
1 1/2" countertop
Distance from top of slat to
centerline of electrical: 24 11/16"
Use of 3 1/2" slats on each
side recommended
149